Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions

被引:63
|
作者
Nevelos, JE
Ingham, E
Doyle, C
Nevelos, AB
Fisher, J [1 ]
机构
[1] Univ Leeds, Dept Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Dept Microbiol, Leeds LS2 9JT, W Yorkshire, England
[3] Stryker Int, Newbury, Berks, England
[4] Bradford Royal Infirm, Bradford BD9 6RJ, W Yorkshire, England
关键词
ceramic; alumina; total hip arthroplasty; wear; hip simulator;
D O I
10.1016/S0142-9612(00)00361-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wear and the biological response to wear debris of artificial joints remain major concerns in total hip arthroplasty (THA). The long-term effects of UHMWPE wear debris are well documented and these have led to interest in alternate bearing materials for THA. Alumina ceramic-ceramic hip joints have been successfully used for more than 30 years with low wear and little incidence of osteolysis. The most common wear pattern observed on retrieved components is an elliptical wear 'stripe' on the heads and a corresponding worn area on the cup with an approximated wear rate of 1-5 mm(3) pa. More severe wear has also occasionally occurred, usually in association with an abnormal clinical history. Modern alumina-alumina THAs use an improved HIPed (hot isostatically pressed) alumina ceramic-bearing material which may be more resistant to severe wear. Previous in vitro simulator studies have not replicated in vivo wear rates or mechanisms. The aim of this study was to compare previous generation non-HIPed alumina and modern HIPed alumina in a hip joint simulator under 'normal' and 'harsh' testing conditions. HIPed alumina was found to have a lower wear rate than non-HIPed alumina, although the difference was not statistically significant at the 95% confidence level. Testing in Gelofusine(R) and water lubricants did not elevate the wear rates of either material. Elevated swing phase load testing also had no significant effect on the wear rates of either material. Testing in the absence of any lubricant produced very severe wear of the non-HIPed material in one specimen only. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2191 / 2197
页数:7
相关论文
共 12 条
  • [1] Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
    Stewart, T
    Tipper, J
    Streicher, R
    Ingham, E
    Fisher, J
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) : 1053 - 1056
  • [2] Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
    T. Stewart
    J. Tipper
    R. Streicher
    E. Ingham
    J. Fisher
    [J]. Journal of Materials Science: Materials in Medicine, 2001, 12 : 1053 - 1056
  • [3] Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
    Nevelos, J
    Ingham, E
    Doyle, C
    Streicher, R
    Nevelos, A
    Walter, W
    Fisher, J
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (06): : 793 - 795
  • [4] Low wear and friction in alumina/alumina total hip joints - A hip simulator study
    Saikko, V
    Pfaff, HG
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 443 - 448
  • [5] Alumina-alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations
    Tipper, JL
    Hatton, A
    Nevelos, JE
    Ingham, E
    Doyle, C
    Streicher, R
    Nevelos, AB
    Fisher, J
    [J]. BIOMATERIALS, 2002, 23 (16) : 3441 - 3448
  • [6] Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision
    Hatton, A
    Nevelos, JE
    Nevelos, AA
    Banks, RE
    Fisher, J
    Ingham, E
    [J]. BIOMATERIALS, 2002, 23 (16) : 3429 - 3440
  • [7] Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation
    Stewart, TD
    Tipper, JL
    Insley, G
    Streicher, RM
    Ingham, E
    Fisher, J
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (06): : 726 - 734
  • [8] Wear testing of total hip replacements under severe conditions
    Zietz, Carmen
    Fabry, Christian
    Reinders, Joern
    Dammer, Rebecca
    Kretzer, Jan Philippe
    Bader, Rainer
    Sonntag, Robert
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (04) : 393 - 410
  • [9] Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model
    Oonishi, H
    Clarke, IC
    Good, V
    Amino, H
    Ueno, M
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 70A (04) : 523 - 532
  • [10] Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions
    Williams, S. R.
    Wu, J. J.
    Unsworth, A.
    Khan, I.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H8) : 783 - 796