Outcome clinical audit: Analyses of interventional closure of patent ductus arteriosus in dogs

被引:0
|
作者
Martin, M. [1 ]
Pedro, B. [2 ]
Dickson, D. [3 ]
Neves, J. [2 ]
Harris, J. [4 ]
Martinez-Pereira, Y. [5 ,6 ]
Oliveira, M., I [5 ,6 ]
Willesen, J. L. [7 ]
Vatne, L. [8 ]
Culshaw, G. J. [5 ,6 ]
Linney, C. [2 ]
机构
[1] Vet Cardiol Consultancy, Leamington Rd, Kenilworth CV8 2AA, Warwick, England
[2] Willows Vet Ctr & Referral Serv, Highlands Rd, Shirley B90 4NH, W Midlands, England
[3] HeartVets, Porthcawl, Wales
[4] HeartVets, Exeter EX4 2HP, Devon, England
[5] Univ Edinburgh, Hosp Small Anim, Royal Dick Sch Vet Studies, Roslin EH25 9RG, Midlothian, Scotland
[6] Univ Edinburgh, Roslin Inst, Roslin EH25 9RG, Midlothian, Scotland
[7] Univ Copenhagen, Univ Hosp Compan Anim, 16 Dyrlaegevej, DK-1870 Copenhagen, Denmark
[8] AniCura Oslo Anim Hosp, Hoffsveien 70c, N-0377 Oslo, Norway
关键词
Amplatz canine duct occluder; Amplatzer vascular plug; Discharge outcome; Complication rate; Interventional cardiac procedures; VENOUS THROMBOSIS; OCCLUSION; CATHETERIZATION; LIGATION;
D O I
10.1016/j.jvc.2022.06.009
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objectives: The objectives of this study were to determine whether conducting a clinical audit was achievable in a group of centres that perform interventional cardiac procedures and to report the success and complications rates in dogs diagnosed with patent ductus arteriosus (PDA). Methods: This was a multi-centre, European-wide, prospective study. Patient data were entered into a bespoke database prior to commencing interventional closure of PDA in all animals undergoing this procedure during the study period. The database was designed to gather clinical audit information, after completion of the procedure, such as discharge outcome, complication rate and medium-term outcome. Results: A total of 339 cases were included from five participating centres. The process of performing clinical audit was achieved in all centres. The successful discharge outcome was 95.9% with a complication rate of 4.1%. The procedure-related mortality was 0.6%. A total of 149 cases (43.9%) were either lost to follow-up or had not yet had a follow-up within the time period. Of the remaining 169 cases in which follow-up was available, 157 (92.9%) had a successful medium-term outcome Conclusions: This study demonstrates that the process of performing a clinical audit is achievable in veterinary clinical interventions across different centres. These results provide a benchmark for future comparison in our ongoing clinical audit and validate the process of clinical audit for other centres performing cardiac interventions. The use of clinical audit should be considered in other aspects of veterinary medicine. (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 50 条
  • [41] DRUG CLOSURE OF PATENT DUCTUS-ARTERIOSUS
    FRIEDMAN, WF
    DRUG THERAPY-CLINICAL THERAPEUTICS IN THE HOSPITAL, 1979, 4 (11): : 22 - &
  • [42] Percutaneous closure of an adult patent ductus arteriosus
    Al Hashimi, H. M. M.
    Wardeh, A. J.
    Aangevaeren, W. R. M.
    Verheugt, F. W. A.
    NETHERLANDS HEART JOURNAL, 2007, 15 (05) : 196 - 197
  • [43] Device Closure of Patent Ductus Arteriosus in Adults
    O'Byrne, Michael L.
    Smith, Christopher L.
    Gillespie, Matthew J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2020, 36 (06) : 795 - 796
  • [44] Transcatheter Device Closure of Patent Ductus Arteriosus
    Sultan, Mehboob
    Ullah, Maad
    Sadiq, Nadeem
    Akhtar, Khurram
    Akbar, Hajira
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2014, 24 (10): : 710 - 713
  • [45] Transcatheter closure of patent ductus arteriosus: Evaluating the effect of the learning curve on the outcome
    Azhar, Ahmad S.
    Abd El-Azim, Ayman A.
    Habib, Hamed S.
    ANNALS OF PEDIATRIC CARDIOLOGY, 2009, 2 (01) : 36 - 40
  • [46] A NEW DEVICE FOR TRANSCATHETER CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS - A FEASIBILITY STUDY IN DOGS
    MAGAL, C
    WRIGHT, KC
    DUPRAT, G
    WALLACE, S
    GIANTURCO, C
    INVESTIGATIVE RADIOLOGY, 1989, 24 (04) : 272 - 276
  • [47] Evaluation of in vivo biocompatibility of different devices for interventional closure of the patent ductus arteriosus in an animal model
    Sigler, M
    Handt, S
    Seghaye, MC
    von Bernuth, G
    Grabitz, RG
    HEART, 2000, 83 (05) : 570 - 573
  • [48] Echocardiographic Evaluation of Myocardial Changes Observed After Closure of Patent Ductus Arteriosus in Dogs
    Hamabe, L.
    Kim, S.
    Yoshiyuki, R.
    Fukayama, T.
    Nakata, T. M.
    Fukushima, R.
    Tanaka, R.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2015, 29 (01) : 126 - 131
  • [49] Mixed reality interactive visualization of cardiovascular anatomy in interventional lab - clinical implementation in transvascular patent ductus arteriosus closure
    Kasprzak, J. D.
    Kierepka, M.
    Zlahoda-Huzior, A.
    Stanuch, M.
    Zolna, D.
    Serafin, J.
    Kasprzak, J., I
    Witowski, J.
    Lipiec, P.
    Wdowiak-Okrojek, K.
    Peruga, J. Z.
    EUROPEAN HEART JOURNAL, 2020, 41 : 3437 - 3437
  • [50] Interventional Closure of a Patent Ductus Arteriosus Using an Amplatz Canine Duct Occluder in an Alpaca Cria
    Chapel, E. C.
    Lozier, J.
    Lakritz, J.
    Schober, K. E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2017, 31 (04): : 1221 - 1224