Quantitative analysis of trace bulk oxygen in silicon wafers using an inert gas fusion method

被引:1
|
作者
Uchihara, H
Ikeda, M
Nakahara, T
机构
[1] HORIBA, Applicat Ctr, Minami Ku, Kyoto 6018510, Japan
[2] Osaka Prefecture Univ, Grad Sch Engn, Dept Appl Chem, Sakai, Osaka 5998531, Japan
关键词
D O I
10.2116/analsci.19.1545
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a method for removing oxide film from the surface of silicon wafers using an inert gas fusion impulse furnace and precise determination of bulk oxygen within the wafer. A silicon wafer was cut to about 0.35 g (6 x 13 x 2 mm) and dropped into a graphite crucible. The sample was then heated for 40 s at 1300degreesC. The wafer's oxide film was reduced by carbon and removed as carbon monoxide. The treated silicon sample was taken out of the graphite crucible and maintained again with the holder of the oxygen analyzer. The graphite crucible was then heated to 2100degreesC. The treated silicon sample was dropped into the heated graphite crucible and the trace bulk oxygen in the wafer was measured using the inert gas fusion infrared absorption method. The relative standard deviations of the oxygen in silicon wafer samples with the removed surface oxide film were determined to be 0.8% for 9.8 x 10(17) atoms/cm(3), and 2.7% for 13.0 x 10(17) atoms/cm(3).
引用
收藏
页码:1545 / 1547
页数:3
相关论文
共 50 条
  • [31] Determination of oxygen in oxide ceramics by inert gas fusion analysis - effect of bath metals -
    Tsuge, Akira
    Uwamino, Yoshinori
    Ishizuka, Toshio
    Watari, Kouji
    Journal of the Ceramic Society of Japan. International ed., 1993, 101 (06): : 696 - 699
  • [32] SYSTEMATIC-ERRORS IN VACUUM AND INERT-GAS FUSION ANALYSIS FOR OXYGEN IN METALS
    COLOMBO, A
    ANALYTICA CHIMICA ACTA, 1976, 81 (02) : 397 - 407
  • [33] DETERMINATION OF OXYGEN AND NITROGEN BY INERT GAS FUSION WITH IMPULSE HEATING
    GOLDBECK, CG
    TUREL, SP
    RODDEN, CJ
    ANALYTICAL CHEMISTRY, 1968, 40 (08) : 1393 - &
  • [34] INERT GAS FUSION DETERMINATION OF OXYGEN IN VANADIUM, NIOBIUM, AND TANTALUM
    KAMIN, GJ
    OLAUGHLIN, JW
    BANKS, CV
    ANALYTICAL CHEMISTRY, 1963, 35 (08) : 1053 - &
  • [35] Evaluation on uncertainty for determining oxygen in SmS by inert gas fusion-infrared absorption method
    Zhang, Yi-Ming, 1600, Editorial Office of Chinese Rare Earths (35):
  • [36] Evaluation of Pure Substances as Oxygen Reference Materials for Inert Gas Fusion Infrared Absorption Method
    Uchihara, Hiroshi
    Sakakura, Seiji
    Bando, Atushi
    BUNSEKI KAGAKU, 2010, 59 (07) : 605 - 611
  • [37] QUANTITATIVE INFRARED-SPECTROSCOPY OF INTERSTITIAL OXYGEN IN SILICON-WAFERS USING MULTIVARIATE CALIBRATION
    LINN, JH
    HANLEY, KL
    APPLIED SPECTROSCOPY, 1993, 47 (12) : 2102 - 2107
  • [38] Effect of dopant on the accuracy of oxygen measurement in silicon by Gas Fusion Analysis
    Chiou, HD
    Pajela, RT
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON DEFECTS IN SILICON, 1999, 99 (01): : 109 - 116
  • [39] DOSIMETER CELLS AND ANALYZERS FOR ASSAYING TRACE OXYGEN IN INERT GASES AND FOR GENERATING INERT GAS FLOWS OF KNOWN OXYGEN CONTENT
    ROSSNER, E
    WIRSIG, M
    KRYSMANN, W
    ZEITSCHRIFT FUR CHEMIE, 1968, 8 (08): : 313 - &
  • [40] Validated method for trace impurities analysis in bulk gas using Gas Chromatography with Pulse Discharge Helium Ionization Detection
    Hindayani, Ayu
    Zuas, Oman
    Mulyana, Muhammad Rizky
    Budiman, Harry
    Styarini, Dyah
    Krismastuti, Fransiska Sri Herwahyu
    Sirenden, Bernadus Herdi
    9TH INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS (ICOPIA), 2019, 1153