Reflected Atomic Magnetometer With Single Beam

被引:5
|
作者
Liu, Xuejing [1 ]
Li, Yang [1 ]
Wu, Xudong [2 ]
Zhang, Rongfu [1 ]
Chang, Min [1 ]
Zhang, Xuedian [1 ,3 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Opt Elect & Comp Engn, Minist Educ, Key Lab Opt Technol & Instrument Med, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Sch Opt Elect & Comp Engn, Shanghai 200093, Peoples R China
[3] Tongji Univ, Shanghai Inst Intelligent Sci & Technol, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic measurements; Optical polarization; Sensitivity; Magnetometers; Atom optics; Atomic beams; Magnetic resonance; magnetometers; optical polarization; MAGNETOENCEPHALOGRAPHY;
D O I
10.1109/JSEN.2021.3128944
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A reflected atomic magnetometer with single beam is described in this study. A single beam propagates forward for polarizing the atoms and backward for detecting Larmor precession after reflection. The feasibility of the system was studied theoretically and experimentally and compared with the single beam with ellipticity. In reflected scheme, high pump efficiency ensures a reduced power and more flexible operating wavelength considering the AC Stark shift, pump efficiency, and probe signal. The nonuniform optical rotation distribution along the cell was also analyzed. The wavelength of the system was optimized to 795.3 nm. The magnetic field sensitivity of the system is achieved to be 600 fT/Hz(1/2) and the experimental bandwidth was 17 Hz. The compact design enables new possibility of the atomic magnetometer for magnetoencephalography systems.
引用
收藏
页码:1238 / 1244
页数:7
相关论文
共 50 条
  • [31] Low-Frequency Light Shift Noise in Single-Beam Atomic Magnetometer: Analysis and Suppression Based on Frequency Response
    Shi, Yanpei
    Guo, Xuyang
    Liu, Ximing
    Tang, Junjian
    Zhai, Yueyang
    Feng, Rui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [32] Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms
    Mehta, Shrey
    Samanta, G. K.
    Grewal, Raghwinder Singh
    APPLIED PHYSICS LETTERS, 2025, 126 (04)
  • [33] Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer
    Miao, Kexuan
    Hu, Tao
    Chang, Yan
    Zhang, Ke-Qin
    Yang, Xiaodong
    IEEE SENSORS JOURNAL, 2025, 25 (05) : 8146 - 8154
  • [34] Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields
    Li, Lin
    Tang, Junjian
    Zhao, Binbin
    Cao, Li
    Zhou, Binquan
    Zhai, Yueyang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (50)
  • [35] Dynamic analysis of atomic magnetometer and co-magnetometer
    Wang, Shihu
    Yu, Linke
    Wang, Wei
    PHYSICA B-CONDENSED MATTER, 2016, 484 : 31 - 35
  • [36] Performance optimization of a SERF atomic magnetometer based on flat-top light beam
    袁子琪
    唐钧剑
    林树东
    翟跃阳
    Chinese Physics B, 2024, 33 (06) : 341 - 347
  • [37] Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam
    Zhang Lu-Lu
    Bai Le-Le
    Yang Yu-Lin
    Yang Yong-Biao
    Wang Yan-Hua
    Wen Xin
    He Jun
    Wang Jun-Min
    ACTA PHYSICA SINICA, 2021, 70 (23)
  • [38] Performance optimization of a SERF atomic magnetometer based on flat-top light beam
    Yuan, Ziqi
    Tang, Junjian
    Lin, Shudong
    Zhai, Yueyang
    CHINESE PHYSICS B, 2024, 33 (06)
  • [39] Metasurface enabled on-chip double-beam scheme for SERF atomic magnetometer
    Liang, Zihua
    Zhou, Binquan
    Lu, Jixi
    Liu, Ying
    Hu, Jinsheng
    Zhou, Peng
    Wang, Weiyi
    Liu, Lu
    Hu, Gen
    Ye, Mao
    OPTICS COMMUNICATIONS, 2022, 525
  • [40] Faraday-Rotation Atomic Magnetometer Using Triple-Chromatic Laser Beam
    Zhang, Yi
    Tian, Yuan
    Li, Songsong
    Chen, Jiehua
    Gu, Sihong
    PHYSICAL REVIEW APPLIED, 2019, 12 (01)