At-home end-tidal carbon dioxide measurement in children with invasive home mechanical ventilation

被引:6
|
作者
Foster, Carolyn C. [1 ,2 ,3 ]
Kwon, Soyang [2 ]
Shah, Avani, V [4 ,5 ]
Hodgson, Caroline A. [5 ]
Hird-McCorry, Lindsey P. [5 ]
Janus, Angela [5 ]
Jedraszko, Aneta M. [2 ]
Swanson, Philip [5 ]
Davis, Matthew M. [1 ,2 ,6 ,7 ,8 ]
Goodman, Denise M. [4 ,9 ]
Laguna, Theresa A. [4 ]
机构
[1] Northwestern Univ, Dept Pediat, Div Adv Gen Pediat & Primary Care, Feinberg Sch Med, 225 East Chicago Ave,Box 162, Chicago, IL 60611 USA
[2] Ann & Robert H Lurie Childrens Hosp Chicago, Mary Ann & J Milburn Smith Child Hlth Outcomes Re, Stanley Manne Childrens Res Inst, Chicago, IL 60611 USA
[3] Ann & Robert H Lurie Childrens Hosp Chicago, Digital Hlth, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Pediat, Div Pulm & Sleep Med, Feinberg Sch Med, Chicago, IL 60611 USA
[5] Ann & Robert H Lurie Childrens Hosp Chicago, Pulm Habilitat Program, Chicago, IL 60611 USA
[6] Northwestern Univ, Dept Med, Feinberg Sch Med, Chicago, IL 60611 USA
[7] Northwestern Univ, Dept Med Social Sci, Feinberg Sch Med, Chicago, IL 60611 USA
[8] Northwestern Univ, Dept Prevent Med, Feinberg Sch Med, Chicago, IL 60611 USA
[9] Northwestern Univ, Dept Pediat, Div Crit Care Med, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
carbon dioxide; children with medical complexity; home mechanical ventilation; long-term mechanical ventilation; remote patient monitoring; TRANSPORTABLE CAPNOMETER; DECANNULATION; DESIGN;
D O I
10.1002/ppul.26092
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end-tidal carbon dioxide (EtCO2) monitoring at home are limited. We hypothesized that a palm-sized, portable endotracheal capnograph (PEC) that measures EtCO2 could be adapted for in-home use in children with HMV. Methods We evaluated the internal consistency of the PEC by calculating an intraclass correlation coefficient of three back-to-back breaths by children (0-17 years) at baseline health in the clinic. Pearson's correlation was calculated for PEC EtCO2 values with concurrent mean values of in-clinic EtCO2 and transcutaneous CO2 (TCM) capnometers. The Bland-Altman test determined their level of agreement. Qualitative interviews and surveys assessed usability and acceptability by family-caregivers at home. Results CO2 values were collected in awake children in varied activity levels and positions (N = 30). The intraclass correlation coefficient for the PEC was 0.95 (p < 0.05). The correlation between the PEC and in-clinic EtCO2 device was 0.85 with a mean difference of -3.8 mmHg and precision of +/- 1.1 mmHg. The correlation between the PEC and the clinic TCM device was 0.92 with a mean difference of 0.2 mmHg and precision of +/- 1.0. Family-caregivers (N = 10) trialed the PEC at home; all were able to obtain measurements at home while children were awake and sometimes asleep. Conclusions A portable, noninvasive device for measuring EtCO2 was feasible and acceptable, with values that trend similarly to currently in-practice, outpatient models. These devices may facilitate monitoring of EtCO2 at home in children with invasive HMV.
引用
收藏
页码:2735 / 2744
页数:10
相关论文
共 50 条
  • [21] End-tidal carbon dioxide as a measure of acidosis among children with gastroenteritis
    Nagler, J
    Wright, RO
    Krauss, B
    PEDIATRICS, 2006, 118 (01) : 260 - 267
  • [22] Anaesthesia for laparoscopic nephrectomy: Does end-tidal carbon dioxide measurement correlate with arterial carbon dioxide measurement?
    Jayan, Nithin
    Jacob, Jaya Susan
    Mathew, Mohan
    INDIAN JOURNAL OF ANAESTHESIA, 2018, 62 (04) : 298 - 302
  • [23] The roll of end-tidal carbon dioxide in Ecpr
    Olander, Carl-Henrik
    Vikholm, Per
    Schiller, Petter
    Hellgren, Laila
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (08) : E3 - E3
  • [24] Alterations of end-tidal carbon dioxide during the intrahospital transport of children
    Tobias, JD
    Lynch, A
    Garrett, J
    PEDIATRIC EMERGENCY CARE, 1996, 12 (04) : 249 - 251
  • [25] Utility of end-tidal carbon dioxide monitoring in critically ill children
    Totapally, Balagangadhar R.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2014, 18 (06) : 341 - 342
  • [26] A bizarre end-tidal carbon dioxide waveform
    Apuya, JS
    Kanter, G
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2002, 49 (10): : 1098 - 1099
  • [27] End-tidal carbon dioxide after sodium bicarbonate infusion during mechanical ventilation or ongoing cardiopulmonary resuscitation
    Roh, Young-Il
    Kim, Hyung Il
    Kim, Sun Ju
    Cha, Kyoung-Chul
    Jung, Woo Jin
    Park, Yeon Jae
    Hwang, Sung Oh.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2024, 76 : 211 - 216
  • [28] More on epinephrine and end-tidal carbon dioxide
    Zeidan, A
    Nahle, N
    ANAESTHESIA, 2005, 60 (04) : 415 - 416
  • [29] The Effects Of Phonation On End-Tidal Carbon Dioxide
    Gillespie, A. I.
    Slivka, W.
    Atwood, C. W.
    Abbott, K. Verdolini
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [30] END-TIDAL CARBON-DIOXIDE AS A MEASURE OF ARTERIAL CARBON-DIOXIDE DURING INTERMITTENT MANDATORY VENTILATION
    WEINGER, MB
    BRIMM, JE
    BRIENZO, RK
    UTLEY, JR
    PETERS, RM
    CHEST, 1981, 80 (03) : 380 - 380