Fluid-structure interaction analyses of stented abdominal aortic aneurysms

被引:41
|
作者
Kleinstreuer, C. [1 ]
Li, Z.
Farber, M. A.
机构
[1] N Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27695 USA
[2] N Carolina State Univ, Dept Biomed Engn, Raleigh, NC 27695 USA
[3] Johnson & Johnson Co, Cordis Corp, Warren, NJ 07059 USA
[4] Univ N Carolina, Dept Surg, Chapel Hill, NC 27599 USA
关键词
aneurysm rupture risk; computer simulation of fluid-structure interactions; benefits of and problems with stent-grafts;
D O I
10.1146/annurev.bioeng.9.060906.151853
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rupture of abdominal aortic aneurysms (AAAs) alone is the thirteenth leading cause of death in the United States. Thus, reliable AAA-rupture risk prediction is an important advancement. If repair becomes necessary, the minimally invasive technique of inserting a stent-graft (SG), commonly referred to as endovascular aneurysm repair (EVAR), is a viable option in many cases. However, postoperative complications, such as endoleaks and/or SG migration, may occur. Computational fluid-structure interaction simulations provide physical insight into the hemodynamics coupled with multi-wall mechanics function as an assessment tool for optimal SG placement and improved device design.
引用
收藏
页码:169 / 204
页数:36
相关论文
共 50 条
  • [41] Fluid Structure Interaction Analysis in Abdominal Aortic Aneurysms: Influence of Diameter, Length, and Distal Neck
    Giuma, S. K. Badreddin
    Osman, Kahar
    Kadir, Mohammed Rafiq Abdul
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) : 514 - 522
  • [42] Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
    Leung, James H.
    Wright, Andrew R.
    Cheshire, Nick
    Crane, Jeremy
    Thom, Simon A.
    Hughes, Alun D.
    Xu, Yun
    BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [43] Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
    James H Leung
    Andrew R Wright
    Nick Cheshire
    Jeremy Crane
    Simon A Thom
    Alun D Hughes
    Yun Xu
    BioMedical Engineering OnLine, 5
  • [44] Application of Fluid–Structure Interaction Methods to Estimate the Mechanics of Rupture in Asian Abdominal Aortic Aneurysms
    Canchi T.
    Saxena A.
    Ng E.
    Pwee E.C.
    Narayanan S.
    Ng, Eyk (mykng@ntu.edu.sg), 2018, Springer Science and Business Media, LLC (08) : 1035 - 1044
  • [45] Fluid structure interaction study in model abdominal aortic aneurysms: Influence of shape and wall motion
    Philip, Nimmy Thankom
    Patnaik, B. S. V.
    B. J., Sudhir
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (03)
  • [46] FLUID-STRUCTURE INTERACTION Fluid-Structure Interaction Issues in Aeronautical Engineering
    Jo, Jong Chull
    Giannopapa, Christina
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE (PVP-2011), VOL 4, 2012, : 421 - 421
  • [47] Computational vascular fluid-structure interaction: methodology and application to cerebral aneurysms
    Bazilevs, Y.
    Hsu, M. -C.
    Zhang, Y.
    Wang, W.
    Kvamsdal, T.
    Hentschel, S.
    Isaksen, J. G.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2010, 9 (04) : 481 - 498
  • [48] A fully-coupled fluid-structure interaction simulation of cerebral aneurysms
    Y. Bazilevs
    M.-C. Hsu
    Y. Zhang
    W. Wang
    X. Liang
    T. Kvamsdal
    R. Brekken
    J. G. Isaksen
    Computational Mechanics, 2010, 46 : 3 - 16
  • [49] Seismic response analyses of fluid-structure system with nonlinear interaction
    Li, YC
    Lou, ML
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 1191 - 1197
  • [50] Influence of wall thickness on fluid-structure interaction computations of cerebral aneurysms
    Torii, Ryo
    Oshima, Marie
    Kobayashi, Toshio
    Takagi, Kiyoshi
    Tezduyar, Tayfun E.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2010, 26 (3-4) : 336 - 347