Pulsed Field Ablation of Superior Vena Cava: Feasibility and Safety of Pulsed Field Ablation

被引:14
|
作者
Zhu, Tongjian [1 ]
Wang, Zhen [1 ]
Wang, Songyun [1 ]
Shi, Tiancai [2 ]
Zhu, Xiaolin [2 ]
Ma, Kezhong [3 ]
Wang, Zhuo [1 ]
Gao, Jinnian [2 ]
Jiang, Hong [1 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Cardiol, Wuhan, Peoples R China
[2] Sichuan Jinjiang Elect Technol Co Ltd, Chengdu, Sichuan, Peoples R China
[3] Hubei Univ Arts & Sci, Affiliated Hosp, Xiangyang Cent Hosp, Dept Cardiol, Xiangyang, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
pulsed field ablation; superior vena cava; arrhythmias; phrenic palsy; sinus node injury; ATRIAL-FIBRILLATION; CATHETER ABLATION; ELECTRICAL ISOLATION; INJURY;
D O I
10.3389/fcvm.2021.698716
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Studies have shown that pulsed field ablation (PFA) has excellent effectiveness and safety in pulmonary vein isolation (PVI). However, there are few reports about the application of PFA, especially the alternating current (AC) biphase PFA, in superior vena cava (SVC) isolation, and its effectiveness and safety are still unclear. Objective: To investigate the efficacy and safety of the AC biphase PFA for SVC isolation, and to provide evidence for the clinical use of PFA for SVC. Methods: Eight pigs and two dogs were included in the study. PFA was delivered to these pigs and dogs. Pacing threshold and electrogram data were recorded before and after PFA. Voltage mapping of SCV was obtained before, after, and 3 weeks after PFA. At the end, all animals were euthanatized for gross pathology analysis. Results: For eight pigs, the median pacing threshold was 1.5 (1.4, 2.75) mA before PFA, while > 6.0 mA after PFA for all animals. The average electrogram amplitude reduction was 61.33 +/- 24.90% for ablations with the initial amplitude >= 0.5 mv. For two dogs, pacing threshold change and electrogram amplitude reduction were also observed. No phrenic palsy or sinus node injury was observed during PFA in any animal. Furthermore, voltage mapping showed that the voltage amplitude was significantly decreased in all animals and this could be kept for more than 3 weeks. Moreover, transmural tissue damage with reserved vessel and nerve were shown, no SVC stenosis was found at 3 weeks after PFA. Conclusion: PFA can effectively isolate SVC. Transmural tissue damage of SVC can be achieved without phrenic palsy, sinus node injury nor SVC stenosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Pulsed field catheter ablation in atrial fibrillation
    Di Biase, Luigi
    Diaz, Juan Carlos
    Zhang, Xiao-Dong
    Romero, Jorge
    TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (06) : 378 - 387
  • [42] Pulsed-Field Ablation and the Coronary Arteries
    Wilber, David J.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (12) : 1497 - 1499
  • [43] Pulsed field ablation for atrial fibrillation: Moving the field forward?
    Mekary, Wissam
    Merchant, Faisal M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (10) : 2027 - 2028
  • [44] Circular Multielectrode Pulsed Field Ablation Catheter Lasso Pulsed Field Ablation Lesion Characteristics, Durability, and Effect on Neighboring Structures
    Yavin, Hagai
    Brem, Erez
    Zilberman, Israel
    Shapira-Daniels, Ayelet
    Datta, Keshava
    Govari, Assaf
    Altmann, Andres
    Anic, Ante
    Wazni, Oussama
    Anter, Elad
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (02): : 157 - 165
  • [45] Investigate the relationship between pulsed field ablation parameters and ablation outcomes
    Zang, Lianru
    Gu, Kaihao
    Zhou, Tuo
    Si, Peng
    Ji, Xingkai
    Zhang, Hao
    Yan, Shengjie
    Wu, Xiaomei
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024,
  • [46] Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation
    Schipper, Jan-Hendrik
    Steven, Daniel
    Lueker, Jakob
    Woermann, Jonas
    van den Bruck, Jan-Hendrik
    Filipovic, Karlo
    Dittrich, Sebastian
    Scheurlen, Cornelia
    Erlhoefer, Susanne
    Pavel, Friederike
    Sultan, Arian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (10) : 2019 - 2026
  • [47] Pulsed field ablation for pulmonary vein isolation: Preclinical safety and effectiveness of a novel hexaspline ablation catheter
    Yu, Fengyuan
    Dong, Xiaonan
    Ding, Lei
    Reddy, Vivek
    Tang, Min
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (11) : 2195 - 2202
  • [48] Posterior wall ablation by pulsed-field ablation: procedural safety, efficacy, and findings on redo procedures
    Kueffer, Thomas
    Tanner, Hildegard
    Madaffari, Antonio
    Seiler, Jens
    Haeberlin, Andreas
    Maurhofer, Jens
    Noti, Fabian
    Herrera, Claudia
    Thalmann, Gregor
    Kozhuharov, Nikola A.
    Reichlin, Tobias
    Roten, Laurent
    EUROPACE, 2023, 26 (01):
  • [49] Pulsed field ablation and cryoballoon ablation for pulmonary vein isolation: insights on efficacy, safety and cardiac function
    Rattka, Manuel
    Mavrakis, Evangelos
    Vlachopoulou, Dimitra
    Rudolph, Isabel
    Kohn, Christina
    Bohnen, Jan
    Yahsaly, Loubna
    Siebermair, Johannes
    Wakili, Reza
    Jungen, Christiane
    Rassaf, Tienush
    Mathew, Shibu
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (05) : 1191 - 1198
  • [50] Feasibility and safety of left atrial access for ablation of atrial fibrillation in patients with persistent left superior vena cava
    Kantenwein, Verena
    Telishevska, Marta
    Bourier, Felix
    Kottmaier, Marc
    Brkic, Amir
    Risse, Elena
    Popa, Miruna
    Lengauer, Sarah
    Kolb, Christof
    Deisenhofer, Isabel
    Hessling, Gabriele
    Reents, Tilko
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (03): : 357 - 364