The Influence of Outdoor Particulate Matter PM2.5 on Indoor Air Quality: The Implementation of a New Assessment Method

被引:6
|
作者
Bekierski, Dominik [1 ]
Kostyrko, Krystyna Barbara [1 ]
机构
[1] Bldg Res Inst ITB, Thermal Phys Acoust & Environm Dept, 1 Filtrowa Str, PL-00611 Warsaw, Poland
关键词
particulate matter; dust pollution; IAQ; indoor-outdoor concentration ratio; penetration factor; air quality control; PARTICLE DEPOSITION RATES; AMBIENT PM2.5; BUILDING ENVELOPE; INFILTRATION; EXPOSURE; PENETRATION; SIZE; PM; MORTALITY; EMISSION;
D O I
10.3390/en14196230
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Epidemiological research has shown that there is a positive correlation between the incidence of disease and mortality in humans and the mass concentration of particulate matter. An average 1 g of suspended dust emitted in a room results in the same exposure as 1 kg emitted to the outside air. In this study, the authors described the state of knowledge on dust pollution inside and outside buildings (I/O ratios), and methods of testing the PM infiltration process parameters. According to the law of indoor-outdoor particle mass balance and the physical basis of aerosol penetration theory, a relatively simple but new method for estimating the penetration factor P was tested. On the basis of the curve of dynamic changes of internal dust concentration in the process of particle concentration decay and next of the followed curve of dynamic rebound of particle concentration, authors measured penetration factor of ambient PM2.5 through building envelope. Authors modification of the method is to be used for determining the value of the particle deposition rate k not from the course of the characteristics in the transient state (the so-called particle concentration decay curves) but from the concentration rebound course, stimulated by natural particle infiltration process. Recognition measurements of the mass concentration of suspended PM2.5 and PM10 particles inside the rooms were carried out. In this study, the choice of the prediction particle penetration factor P calculation method was supported by the exemplary calculation of the p value for a room polluted by PM2.5. The preliminary results of the penetration factors determined by this method P = 0.61 are consistent with the P factor values from the literature obtained so far for this dimensional group of dusts.
引用
收藏
页数:30
相关论文
共 50 条
  • [31] Experimental and numerical analysis of indoor air quality affected by outdoor air particulate levels (PM1.0, PM2.5 and PM10), room infiltration rate, and occupants' behaviour
    Fu, Nuodi
    Kim, Moon Keun
    Huang, Long
    Liu, Jiying
    Chen, Bing
    Sharples, Stephen
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 851
  • [32] Particulate Matter (PM2.5) Characterization, Air Quality Level and Origin of Air Masses in an Urban Background in Pretoria
    Adeyemi, Adewale
    Molnar, Peter
    Boman, Johan
    Wichmann, Janine
    [J]. ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2022, 83 (01) : 77 - 94
  • [33] Particulate Matter (PM2.5) Characterization, Air Quality Level and Origin of Air Masses in an Urban Background in Pretoria
    Adewale Adeyemi
    Peter Molnar
    Johan Boman
    Janine Wichmann
    [J]. Archives of Environmental Contamination and Toxicology, 2022, 83 : 77 - 94
  • [34] The Microbial Activity in PM2.5 in Indoor Air: As an Index of Air Quality Level
    Chen, Hanlin
    Du, Rui
    Ren, Weishan
    Zhang, Sujian
    Du, Pengrui
    Zhang, Yongtao
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (02) : 1 - 13
  • [35] Are we safe inside? Indoor air quality in relation to outdoor concentration of PM10 and PM2.5 and to characteristics of homes
    Scibor, Monika
    Balcerzak, Bartosz
    Galbarczyk, Andrzej
    Targosz, Nikodem
    Jasienska, Grazyna
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2019, 48
  • [36] Assessment of Indoor-Outdoor Particulate Matter Air Pollution: A Review
    Bo, Matteo
    Salizzoni, Pietro
    Clerico, Marina
    Buccolieri, Riccardo
    [J]. ATMOSPHERE, 2017, 8 (08)
  • [37] Application of Photo Texture Analysis and Weather Data in Assessment of Air Quality in Terms of Airborne PM10 and PM2.5 Particulate Matter
    Chuchro, Monika
    Sarlej, Wojciech
    Grzegorczyk, Marta
    Nurzynska, Karolina
    [J]. SENSORS, 2021, 21 (16)
  • [38] A new method for measurement of air change rate based on indoor PM2.5 removal
    P. Y. Ni
    H. C. Jin
    X. L. Wang
    G. N. Xi
    [J]. International Journal of Environmental Science and Technology, 2018, 15 : 2561 - 2568
  • [39] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    FENG C TSAI
    KIRK R SMITH
    NUNTAVARN VICHIT-VADAKAN
    BART D OSTRO
    LAURAINE G CHESTNUT
    NIPAPUN KUNGSKULNITI
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 15 - 26
  • [40] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    Tsai, FC
    Smith, KR
    Vichit-Vadakan, N
    Ostro, BD
    Chestnut, LG
    Kungskulniti, N
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (01): : 15 - 26