Retained Metallic Intraocular Foreign Body With Excellent Visual Outcome

被引:0
|
作者
She, Poh Fong [1 ,2 ]
Tai, Evelyn [3 ]
Zamli, Akmal Haliza [2 ]
Rashid, Rohana Abdul [2 ]
Khialdin, Safinaz Mohd [1 ]
机构
[1] Univ Kebangsaan Malaysia, Med Ctr, Ophthalmol, Kuala Lumpur, Malaysia
[2] Hosp Tengku Ampuan Afzan, Ophthalmol, Kuantan, Malaysia
[3] Univ Sains Malaysia, Sch Med Sci, Ophthalmol, Kubang Kerian, Malaysia
关键词
endophthalmitis; siderosis bulbi; metallic foreign body; penetrating ocular injuries; intraocular foreign body; OPEN GLOBE INJURIES; PROGNOSTIC-FACTORS; OCULAR TRAUMA; BODIES;
D O I
10.7759/cureus.18633
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A healthy 25-year-old gentleman sustained a left eye perforating injury involving a metallic intraocular foreign body. Upon examination, his best-corrected visual acuity was 6/6 in the right eye and 1/60 in the left eye. There was a full thickness cornea-scleral laceration wound with uveal tissue prolapse at 7 o'clock. The pupil was peaked inferonasally. The anterior chamber was deep with cells grade 4+ and a hyphema level. The posterior segment could not be visualized due to a vitreous haemorrhage. The computed tomography scan revealed a high-density foreign body embedded in the posterior wall of the globe. He underwent primary toilet and suturing of the left eye cornea-scleral laceration, followed by pars plana vitrectomy with an endolaser and gas tamponade. However, the foreign body could not be identified intraoperatively. Postoperation, the left eye vision improved, achieving his premorbid best-corrected visual acuity of 6/6 by six months post-op. The intraocular foreign body was managed conservatively in view of the excellent visual acuity and the risk of further surgery. The patient has remained asymptomatic since then until his last follow-up at 30 months post-operation.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Visual outcome of pars plana vitrectomy with intraocular foreign body removal through sclerocorneal tunnel and sulcus-fixated intraocular lens implantation as a single procedure, in cases of metallic intraocular foreign body with traumatic cataract
    Mahapatra, Santosh K.
    Rao, Nageswar G.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (02) : 115 - 118
  • [22] ELECTRORETINOGRAPHY IN EYES WITH RETAINED INTRAOCULAR METALLIC FOREIGN BODIES - A CLINICAL STUDY
    KNAVE, B
    ACTA OPHTHALMOLOGICA, 1969, S : 5 - &
  • [23] Retained intraocular copper foreign body presenting as subretinal abscess
    Kumar, Vinod
    Surve, Abhidnya
    Balasubramaniam, Niranjana
    Azad, Shorya
    Venkatesh, Pradep
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2019, 54 (05): : E254 - E258
  • [24] Retained intraocular foreign body masquerading as malignant melanoma of the iris
    Maat, W.
    Missotten, G. S.
    Luyten, G. P. M.
    de Keizer, R. J. W.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (04) : 623 - 624
  • [25] Retained intraocular foreign body masquerading as malignant melanoma of the iris
    W. Maat
    G. S. Missotten
    G. P. M. Luyten
    R. J. W. de Keizer
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2008, 246 : 623 - 624
  • [26] The varied presentations of siderosis from retained intraocular foreign body
    Dowlut, Mohammad S.
    Curragh, David S.
    Napier, Maria
    Herron, Brian
    McIlwaine, Gawn
    Best, Richard
    Chan, Wing
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (01) : 86 - 88
  • [27] An overview of penetrating ocular trauma with retained intraocular foreign body
    Al-Thowaibi, Awwadh
    Kumar, Mohan
    Al-Matani, Ibrahim
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2011, 25 (02) : 203 - 205
  • [28] Unusual presentation of an intraocular foreign body retained for sixty years
    Gokmen, Onur
    Yesilirmak, Nilufer
    Kal, Ali
    Eroglu, Fatma C.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (03): : 234 - 235
  • [29] Metallic intraocular foreign bodies: Characteristics, interventions, and prognostic factors for visual outcome and globe survival
    Ehlers, Justis P.
    Kunimoto, Derek Y.
    Ittoop, Sabita
    Maguire, Joseph I.
    Ho, Allen C.
    Regillo, Carl D.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (03) : 427 - 433
  • [30] Retinal damage caused by a metallic intraocular foreign body
    Mottet, B.
    Combey-De Lambert, A.
    Chibani, A.
    Lacharme, T.
    Savy, O.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2014, 37 (01): : 81 - 81