Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

被引:0
|
作者
Taeubner, Angelika
Bruns, Thomas
机构
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison CCAUV.V-S1 was organized to compare measurements of sinusoidal angular accelerations in the frequency range from 0.4 Hz to 1 kHz. This was a bilateral comparison between the Korea Research Institute of Standards and Science (KRISS), Republic of Korea, and the Physikalisch-Technische Bundesanstalt (PTB), Germany. Both NMIs applied laser interferometry in compliance with ISO 16063-15:2006 "Methods for the calibration of vibration and shock transducers - Part 15: Primary angular vibration calibration by laser interferometry". The complex voltage sensitivity (magnitude and phase) of one angular transfer standard in the frequency range of 0.4 Hz to 100 Hz and the complex charge sensitivity (magnitude and phase) of one angular reference standard in the frequency range of 1 Hz to 1000 Hz were measured.
引用
收藏
页数:53
相关论文
共 50 条
  • [2] A Comparison Angular Vibration Calibration Approach Based on the IFOG
    Xianfan Wang
    Jiapeng Mou
    Lijun Miao
    Tengchao Huang
    Shuangliang Che
    MAPAN, 2021, 36 : 607 - 613
  • [3] A Comparison Angular Vibration Calibration Approach Based on the IFOG
    Wang, Xianfan
    Mou, Jiapeng
    Miao, Lijun
    Huang, Tengchao
    Che, Shuangliang
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2021, 36 (03): : 607 - 613
  • [4] Linking the results of the regional key comparison APMP.AUV.V-K1 to those of the CIPM key comparison CCAUV.V-K1
    Von Martens, H-J
    Elster, C.
    Link, A.
    Woeger, W.
    Allisy, P. J.
    METROLOGIA, 2004, 41
  • [5] Bilateral Comparison EURAMET. AUV.V-K1.2 (vibration acceleration)
    Hof, Christian
    Thomas, Bruns
    METROLOGIA, 2011, 48
  • [6] Bilateral comparison in torque transducer calibration between CENAM, Mexico and CEM, Spain, SIM.M.T-S1
    Torres-Guzman J.C.
    Martin M.N.M.
    Izquierdo M.C.G.
    Mancilla J.J.G.
    Verdecia J.L.R.
    Metrologia, 2022, 59 (1 A)
  • [7] Supplementary comparison EURAMET EM-S41 bilateral comparison of DC voltage reference standards (1,018 V and 10 V) (EURAMET.EM-S41)
    Blanc, Isabelle
    Sardjono, Hadi
    Syahadi, Mohamad
    METROLOGIA, 2020, 57 (1A)
  • [8] SIMMT-S2 supplementary bilateral comparison calibration of a reference torque wrench final report
    Galvan, J. J.
    Torres-Guzman, J. C.
    Arias, J. A.
    Betancur, I. D.
    METROLOGIA, 2020, 57 (1A)
  • [9] Bilateral comparison on the calibration of a set of F1 mass standards between IBMETRO (Bolivia) and INTI (Argentina)
    Quille, Ruben
    Sanchez, Jorge
    Escalante, Boris
    METROLOGIA, 2017, 54
  • [10] Final report on the supplementary comparison EURAMET.AUV.V-S1
    Rosenkranz P.
    Virovska D.
    Prasil M.
    Ribeiro L.F.
    Maina A.K.
    Hof C.
    Hämäläinen J.
    Bruns T.
    Sadikoglu E.
    Metrologia, 2022, 59 (1 A)