Detection and prediction of acute heart transplant rejection with the myocardial T2 determination provided by a black-blood magnetic resonance imaging sequence

被引:121
|
作者
Marie, PY
Angioï, M
Carteaux, JP
Escanye, JM
Mattei, S
Tzvetanov, K
Claudon, O
Hassan, N
Danchin, N
Karcher, G
Bertrand, A
Walker, PM
Villemot, JP
机构
[1] CHU Nancy, Dept Nucl Med, UPRES EA 2403, Nancy, France
[2] CHU Nancy, Dept Cardiol, UPRES EA 2403, Nancy, France
[3] CHU Nancy, Dept Cardiac Surg, UPRES EA 2403, Nancy, France
[4] CHU Dijon, Dept Nucl Med, Dijon, France
关键词
D O I
10.1016/S0735-1097(00)01196-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study aimed to determine whether the myocardial T-2 relaxation time, determined using a black-blood magnetic resonance imaging (MRI) sequence, could predict acute heart transplant rejection. BACKGROUND The use of black-blood MRI sequences allows suppression of the confusing influence of blood signal when myocardial T-2 is calculated to detect myocardial edema. METHODS A total of 123 investigations, including cardiac MRI and myocardial biopsy, were performed 8 +/- 11 months after heart transplantation. Myocardial T-2 was determined using an original inversion-recovery/spin-echo sequence. RESULTS A higher than normal T-2 (greater than or equal to 56 ms) allowed an accurate detection of the moderate acute rejections evidenced at baseline biopsy (greater than or equal to International Society for Heart and Lung Transplantation grade 2): sensitivity, 89% and specificity, 70% (p < 0.0001). T-2 was increased in grade 2 (n = 11) compared with grade 0 (n = 49, p < 0.05), grade 1A (n = 34, p < 0.05) and grade 1B (n = 21, p < 0.05); T-2 was further increased in grade 3 (n = 8) compared with grade 2 (p < 0.05). In addition, in patients without rejection equal to or greater than grade 2 at baseline, a T-2 higher than normal (<greater than or equal to>56 ms) was correlated with the subsequent occurrence of equal or greater than grade 2 rejection within the next three months: sensitivity 63% (12/19) and specificity 78% (64/82) (p = 0.001). CONCLUSIONS Myocardial T-2 determined using a black-blood MRI sequence, is sufficiently sensitive to identify most; of the moderate acute rejections documented with biopsy at the same time, but is also a predictor of the subsequent occurrence of such biopsy-defined rejections. (J Am Coil Cardiol 2001;37:825-31) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:825 / 831
页数:7
相关论文
共 50 条
  • [21] THE ASSESSMENT OF REPERFUSION HAEMORRHAGE FOLLOWING ACUTE MYOCARDIAL INFARCTION BY T2 AND T2*CARDIOVASCULAR MAGNETIC RESONANCE
    Mather, A. N.
    Radjenovic, S.
    Greenwood, J. P.
    Plein, S.
    HEART, 2010, 96 : A45 - A46
  • [22] The assessment of reperfusion haemorrhage following acute myocardial infarction by T2 and T2* cardiovascular magnetic resonance
    Adam N Mather
    Aleksandra Radjenovic
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [23] Cardiac Magnetic Resonance in heart transplant patients: diagnostic value of quantitative tissue markers (T2 mapping and ECV) for acute cardiac rejection diagnosis
    Vermes E.
    Pantaleon C.
    pucheux J.
    Aupart M.
    Cazeneuve N.
    Brunereau L.
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [24] Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial infarction at 3 Tesla
    Kidambi, Ananth
    Biglands, John D.
    Higgins, David M.
    Ripley, David P.
    Zaman, Arshad
    Broadbent, David A.
    McDiarmid, Adam K.
    Swoboda, Peter P.
    Al Musa, Tarique
    Erhayiem, Bara
    Greenwood, John P.
    Plein, Sven
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16 : 86
  • [25] Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial infarction at 3 Tesla
    Ananth Kidambi
    John D Biglands
    David M Higgins
    David P Ripley
    Arshad Zaman
    David A Broadbent
    Adam K McDiarmid
    Peter P Swoboda
    Tarique Al Musa
    Bara Erhayiem
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 16
  • [26] Cardiovascular magnetic resonance black-blood thrombus imaging for the diagnosis of acute deep vein thrombosis at 1.5 Tesla
    Chen, Hanwei
    He, Xueping
    Xie, Guoxi
    Liang, Jianke
    Ye, Yufeng
    Deng, Wei
    He, Zhuonan
    Liu, Dexiang
    Li, Debiao
    Liu, Xin
    Fan, Zhaoyang
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [27] Cardiovascular magnetic resonance black-blood thrombus imaging for the diagnosis of acute deep vein thrombosis at 1.5 Tesla
    Hanwei Chen
    Xueping He
    Guoxi Xie
    Jianke Liang
    Yufeng Ye
    Wei Deng
    Zhuonan He
    Dexiang Liu
    Debiao Li
    Xin Liu
    Zhaoyang Fan
    Journal of Cardiovascular Magnetic Resonance, 20
  • [28] Comparison of white blood and black blood T2* cardiovascular magnetic resonance at 3 Tesla
    Mohammed H Alam
    Gillian C Smith
    John Paul Carpenter
    Arun J Baksi
    Ricardo Wage
    Peter Drivas
    Karen Symmonds
    Taigang He
    David Firmin
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [29] Cardiac Magnetic Resonance T2 Mapping in the Monitoring and Follow-up of Acute Cardiac Transplant Rejection A Pilot Study
    Usman, Asad A.
    Taimen, Kirsi
    Wasielewski, Marie
    McDonald, Jennifer
    Shah, Saurabh
    Giri, Shivraman
    Cotts, William
    McGee, Edwin
    Gordon, Robert
    Collins, Jeremy D.
    Markl, Michael
    Carr, James C.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (06) : 782 - 790
  • [30] Acute pancreatitis with gradient echo T2*-weighted magnetic resonance imaging
    Tang, Meng Yue
    Chen, Tian Wu
    Huang, Xiao Hua
    Li, Xing Hui
    Wang, Si Yue
    Liu, Nian
    Zhang, Xiao Ming
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (02) : 157 - 167