摘要
The precision of the Al-26-Mg-26 system-one of the most widely used chronometers for constraining the relative timing of events in the early solar system-is presently limited by methods for the determination of Al-27/Mg-24 ratios, which have seen little improvement in the last decade. We present a novel method for the measurement of Al-27/Mg-24 ratios in unpurified sample solutions by multiple-collector inductively coupled plasma mass spectrometry. Because Al is monoisotopic we use a modified isotope dilution approach that employs a mixed spike containing isotopically enriched Mg-25 and natural Al-27 in an accurately known ratio. In order to determine the spike to sample ratio for Al, measurements of spiked aliquots are bracketed by unspiked aliquots, which negates the impact of elemental bias. Unlike conventional isotope dilution, samples do not require chromatographic separation prior to analysis, which both saves time and minimises the risk of contamination of other samples with spike (which is added immediately prior to analysis). Repeat measurements of the BHVO-2, BCR-2, and BIR-1 international rock standards, as well as a gravimetrically prepared Al-Mg reference solution, indicate that our method is both accurate and reproducible to 0.2%. This 4- to 10-fold improvement over previous methods translates directly to an equal gain in the resolution of the Al-26-Mg-26 chronometer. The approach presented here could, in principle, be applied to other monoisotopic elements such as the Mn-Cr system. Based on multiple measurements of a similar to 2.7 gram piece of the Ivuna CI chondrite, we present a new estimate for the Al-27/Mg-24 ratio of this meteorite of 0.09781 +/- 0.00029.
引用
收藏
页码:644 / 652
页数:9
相关论文
共 50 条
  • [41] DETERMINATION OF ELECTROLYTE APPARENT MOLAL COMPRESSIBILITIES AT INFINITE DILUTION USING A HIGH-PRECISION ULTRASONIC VELOCIMETER
    GARNSEY, R
    BOE, RJ
    MAHONEY, R
    LITOVITZ, TA
    JOURNAL OF CHEMICAL PHYSICS, 1969, 50 (12): : 5222 - &
  • [42] A novel approach for high sensitive determination of sulfur mustard by derivatization and isotope-dilution LC-MS/MS analysis
    Xu, Bin
    Zong, Cheng
    Nie, Zhiyong
    Guo, Lei
    Xie, Jianwei
    TALANTA, 2015, 132 : 245 - 251
  • [43] High-precision quadruple isotope dilution method for simultaneous determination of nitrite and nitrate in seawater by GCMS after derivatization with triethyloxonium tetrafluoroborate
    Pagliano, Enea
    Meija, Juris
    Mester, Zoltan
    ANALYTICA CHIMICA ACTA, 2014, 824 : 36 - 41
  • [44] PRECISION DETERMINATION OF MASS DIFFERENCE AL27-MG24 FROM REACTIONS MG24(ALPHA,GAMMA)SI28 AND AL27(RHO,GAMMA)SI28
    RYTZ, A
    ZAMBONI, F
    WINKLER, H
    STAUB, HH
    HELVETICA PHYSICA ACTA, 1962, 35 (7-8): : 546 - &
  • [45] Cross-section measurements to low-lying excited final states in the 24Mg(α, p) 27Al* (γ) reaction as an energy source for x-ray bursts
    Ahn, T.
    Aguilar, S.
    DeBoer, R. J.
    Bardayan, D. W.
    Boeltzig, A.
    Brune, C. R.
    Burcher, S. P.
    Chae, K. Y.
    Henderson, S. L.
    Grzywacz, R. K.
    Jones, K. L.
    Kovoor, J. M.
    Macon, K. T.
    Manukyan, K.
    Mosby, S.
    O'Malley, P. D.
    Renaud, M.
    Smith, K.
    Thornsberry, C.
    Vande Kolk, B.
    Wiescher, M.
    PHYSICAL REVIEW C, 2020, 102 (03)
  • [46] Fast high-precision on-line determination of hydrogen isotope ratios of water or ice by continuous-flow isotope ratio mass spectrometry
    Huber, C
    Leuenberger, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (12) : 1319 - 1325
  • [47] High accuracy isotope dilution analysis for the determination of ethanol using gas chromatography-combustion-isotope ratio mass spectrometry
    Briche, CSJW
    Hernández, H
    O'Connor, G
    Webb, KS
    Catterick, T
    ANALYST, 2000, 125 (12) : 2189 - 2195
  • [48] Assessing metabolism of beta-[C-13]carotene using high-precision isotope ratio mass spectrometry
    Parker, RS
    Brenna, JT
    Swanson, JE
    Goodman, KJ
    Marmor, B
    VITAMINS AND COENZYMES, PT L, 1997, 282 : 130 - 140
  • [49] AN ANALYSIS OF 27AL(P,ALPHA)24MG AND 23NA(P,ALPHA)20NE DIRECT REACTION PROCESS AT 41.3-MEV AND45.5-MEV
    KOST, CJ
    HIRD, B
    NUCLEAR PHYSICS A, 1969, A132 (03) : 611 - &
  • [50] High-Precision Pb Isotope Ratio Determination of Zircon By Multi-Ion Counter TIMS with Multi-Dynamic Collection Method
    Wang W.
    Chu Z.
    Li C.
    Liu W.
    Xu J.
    Guo J.
    Diqiu Kexue - Zhongguo Dizhi Daxue Xuebao/Earth Science - Journal of China University of Geosciences, 2020, 45 (06): : 1977 - 1985