Determination of storage lengths of left-turn lanes at unsignalized intersections using M/G2/1 queuing

被引:0
|
作者
Lertworawanich, P [1 ]
Elefteriadou, L [1 ]
机构
[1] Penn State Univ, Penn Transportat Inst, University Pk, PA 16802 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Inadequate lengths of left-turning lanes can have negative effects on the performance of unsignalized intersections. Existing methods are inadequate for recommending appropriate storage lengths as a function of the traffic demands. This study uses an M/G2/1 queuing system to develop a model for determining storage lengths of left-turning lanes for unsignalized intersections based on probability of lane overflow. Left-turning vehicle arrivals are assumed to be Poisson arrival processes. Service times of left-turning vehicles are categorized into two groups: (a) service times incurred by the vehicles that arrive when the left-turning lane is empty, and (b) service times incurred by the vehicles that arrive when the left-turning lane is not empty. The effects of heavy vehicles on lengths of left-turning lanes are also taken into account. Recommended storage lengths of left-turning lanes are estimated using the proposed method and are provided for various combinations of opposing volumes, left-turning volumes, and threshold probabilities of lane overflow. To select values of the threshold probability of lane overflow, many factors should be considered, such as safety, site-specific conditions, accident records, operating speeds, and economics. The results of the proposed method were compared to those provided in the 2001 AASHTO Green Book. The 2001 AASHTO Green Book overestimates the storage lengths required for left-turning lanes when opposing and left-turning volumes have fewer than 900 vehicles per hour and 500 vehicles per hour, respectively, but it underestimates storage lengths when left-turning volumes are near capacity.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 37 条
  • [21] Determination of aflatoxins M1, M2, B1, B2, G1 and G2 in peanut by modified QuEChERS method and ultra-high performance liquid chromatography-tandem mass spectrometry
    Sartori, Andre Victor
    de Mattos, Juliana Swensson
    Souza, Yuri Pereira
    dos Santos, Rosana Pereira
    Paulino de Moraes, Maria Heloisa
    da Nobrega, Armi Wanderley
    VIGILANCIA SANITARIA EM DEBATE-SOCIEDADE CIENCIA & TECNOLOGIA, 2015, 3 (03): : 115 - 121
  • [22] Simultaneous determination of aflatoxins B1, B2, G1, G2, M1 and M2 in peanuts and their derivative products by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Huang, Baifen
    Han, Zheng
    Cai, Zengxuan
    Wu, Yongjiang
    Ren, Yiping
    ANALYTICA CHIMICA ACTA, 2010, 662 (01) : 62 - 68
  • [23] Determination of Aflatoxins B1, B2, G1, and G2 and Ochratoxin A in Dry Fermented Sausages Using a Dilute and Shoot Method and LC–MS/MS
    Douglas Evangelista Braga
    Rafael von Sperling de Souza
    Fabiano Narciso Paschoal
    Raquel Eduardo Bickel
    Daniela Peralva Lima
    José Eduardo Gonçalves
    Maria Beatriz Abreu Gloria
    Food Analytical Methods, 2023, 16 : 1437 - 1445
  • [24] An ultra-high-performance liquid chromatography-tandem mass spectrometry method for simultaneous determination of aflatoxins B1, B2, G1, G2, M1 and M2 in traditional Chinese medicines
    Han, Zheng
    Zheng, Yunliang
    Luan, Lianjun
    Cai, Zengxuan
    Ren, Yiping
    Wu, Yongjiang
    ANALYTICA CHIMICA ACTA, 2010, 664 (02) : 165 - 171
  • [25] Determination of Aflatoxins B1, B2, G1, and G2 and Ochratoxin A in Dry Fermented Sausages Using a Dilute and Shoot Method and LC-MS/MS
    Braga, Douglas Evangelista
    von Sperling de Souza, Rafael
    Paschoal, Fabiano Narciso
    Bickel, Raquel Eduardo
    Lima, Daniela Peralva
    Goncalves, Jose Eduardo
    Gloria, Maria Beatriz Abreu
    FOOD ANALYTICAL METHODS, 2023, 16 (8) : 1437 - 1445
  • [26] Determination of Aflatoxins M1, M2, B1, B2, G1, and G2 and Ochratoxin A in UHT and Powdered Milk by Modified QuEChERS Method and Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry
    André Victor Sartori
    Juliana Swensson de Mattos
    Maria Heloísa Paulino de Moraes
    Armi Wanderley da Nóbrega
    Food Analytical Methods, 2015, 8 : 2321 - 2330
  • [27] Determination of Aflatoxins M1, M2, B1, B2, G1, and G2 and Ochratoxin A in UHT and Powdered Milk by Modified QuEChERS Method and Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry
    Sartori, Andre Victor
    de Mattos, Juliana Swensson
    Paulino de Moraes, Maria Heloisa
    da Nobrega, Armi Wanderley
    FOOD ANALYTICAL METHODS, 2015, 8 (09) : 2321 - 2330
  • [28] Identification of Immunoglobulin E-binding epitopes in soybean gly m conglycinin, Gly m glycinin G1/G2 and two 2S albumins using peptide microarray immunoassay
    Han, Y. S.
    Lin, J.
    Bardina, L.
    Bruni, F. M.
    Ayuso, R.
    Sampson, H. A.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (02) : S248 - S248
  • [29] Simultaneous determination of aflatoxins B1, B2, G1 and G2 in commercial rices using immunoaffinity column clean-up and HPLC-MS/MS
    Romero-sanchez, Ivan
    Ramirez-Garcia, Lorena
    Gracia-Lor, Emma
    Madrid-Albarran, Yolanda
    FOOD CHEMISTRY, 2022, 395
  • [30] Broad-spectrum immunoaffinity cleanup for the determination of aflatoxins B1, B2, G1, G2, M1, M2 in Ophiocordyceps sinensis and its pharmaceutical preparations by ultra performance liquid chromatography tandem mass spectrometry
    Sun, Shujuan
    Xie, Jie
    Peng, Tao
    Shao, Bing
    Zhu, Kui
    Sun, Yuanze
    Yao, Kai
    Gu, Qiang
    Zhang, Jing
    Fan, Chunlin
    Chen, Ying
    Jiang, Haiyang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1068 : 112 - 118