Evaluation of a complete denture trial method applying rapid prototyping

被引:116
|
作者
Inokoshi, Masanao [1 ]
Kanazawa, Manabu [1 ]
Minakuchi, Shunsuke [1 ]
机构
[1] Tokyo Med & Dent Univ, Dept Oral Masticatory Funct Rehabil, Div Oral Hlth Sci, Grad Sch Med & Dent Sci,Bunkyo Ku, Tokyo 1138549, Japan
关键词
Complete denture; CAD/CAM; Rapid prototyping; Evaluation; Trial; IMPRESSION TECHNIQUE; IMPLANT PLACEMENT; CAD/CAM; TECHNOLOGY; RECONSTRUCTIONS; ACCURACY;
D O I
10.4012/dmj.2011-113
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A new trial method for complete dentures using rapid prototyping (RP) was compared with the conventional method. Wax dentures were fabricated for 10 edentulous patients. Cone-beam CT was used to scan the wax dentures. Using 3D computer-aided design software, seven 3D denture images with different artificial teeth arrangements were made and seven trial dentures per patient were fabricated accordingly. Two prosthodontists performed a denture try-in for one patient using both conventional and RP methods. The prosthodontists and patients rated satisfaction for both methods using a visual analogue scale. Satisfaction ratings with both conventional and RP methods were compared using the Wilcoxon signed-rank test. Regarding prosthodontist's ratings, esthetics and stability were rated significantly higher with the conventional method than with the RP method, whereas chair time was rated significantly longer with the RP method than with the conventional method. Although further improvements are needed, the trial method applying RP seems promising.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 50 条
  • [41] Evaluation and exploration of RFID systems by rapid prototyping
    Angerer, Christoph
    Langwieser, Robert
    Rupp, Markus
    PERSONAL AND UBIQUITOUS COMPUTING, 2012, 16 (03) : 309 - 321
  • [42] Evaluation of the treatment of halitosis with photodynamic therapy in older patients with complete denture Protocol for a randomized, controlled trial
    do Vale, Katia Llanos
    Ratto Tempestini Horliana, Anna Carolina
    Romero, Sergio dos Santos
    Deana, Alessandro de Melo
    Leal Goncalves, Marcela Leticia
    Mesquita Ferrari, Raquel Agnelli
    Bussadori, Sandra Kalil
    Santos Fernandes, Kristianne Porta
    MEDICINE, 2019, 98 (27) : e16275
  • [43] Evaluation of alginate impression technique for complete denture prothesis
    Pajuaba, PNA
    Vasconcellos, WA
    Pereira, AH
    Jansen, WC
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1096 - 1096
  • [44] Rapid Prototyping and Evaluation of In-Vehicle Interfaces
    Salvucci, Dario D.
    ACM TRANSACTIONS ON COMPUTER-HUMAN INTERACTION, 2009, 16 (02) : 1 - 33
  • [45] Evaluation of teeth movements in complete denture by microwaves polymerization
    Marchini, L
    Araújo, MAM
    Araújo, JEJ
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B133 - B133
  • [46] EVALUATION OF FACTORS PERTINENT TO SUCCESS OF COMPLETE DENTURE SERVICE
    YOSHIZUMI, DT
    JOURNAL OF PROSTHETIC DENTISTRY, 1964, 14 (05): : 866 - &
  • [47] Shift construction method: From rapid prototyping to rapid manufacturing
    Stotko, Christof M.
    Konstruktion, 2009, (10): : 48 - 50
  • [48] CLINICAL-EVALUATION OF POLYVINYLSILOXANE FOR COMPLETE DENTURE IMPRESSIONS
    APPELBAUM, EM
    MEHRA, RV
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (04): : 537 - 539
  • [49] Evaluation of anxiety in patients undergoing complete denture treatment
    Pasad, Ankita Kirti
    Baviskar, Padmakar Sudhakar
    Nadgere, Jyoti Bhushan
    Iyer, Janani Vivek
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2021, 21 (01): : 66 - 73
  • [50] THE USE OF GRAPHOANALYSIS FOR COMPLETE DENTURE PATIENT-EVALUATION
    POTGIETER, PJ
    CAREY, PD
    JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (05): : 623 - 626