Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in cats

被引:2
|
作者
Ricci, Claudia Lizandra [1 ]
Giuffrida, Rogerio [2 ]
Kanashiro, Glaucia Prada [3 ]
Rufino Belezzi, Hilidia Stephania [4 ]
Bacarin, Carolina de Carvalho [4 ]
Tenorio, Michele Paulo [4 ]
Duran Foglia, Bruna Toledo [4 ]
Andrade, Silvia Franco [5 ,6 ]
机构
[1] Univ Oeste Paulista UNOESTE, Curso Med Vet, Ciencia Anim, Presidente Prudente, SP, Brazil
[2] Univ Oeste Paulista, Curso Med Vet, Dept Bioestat, Presidente Prudente, SP, Brazil
[3] Univ Oeste Paulista, Curso Med Vet, Dept Anestesiol, Presidente Prudente, SP, Brazil
[4] Univ Oeste Paulista, Curso Curso Med Vet, Presidente Prudente, SP, Brazil
[5] Univ Oeste Paulista, Curso Med Vet, Dept Clin Med Pequenos Anim, Presidente Prudente, SP, Brazil
[6] Univ Oeste Paulista, Ciencia Anim, Presidente Prudente, SP, Brazil
来源
SEMINA-CIENCIAS AGRARIAS | 2017年 / 38卷 / 06期
关键词
Applanation tonometer; Ocular manometry; Intraocular pressure; Cats; TONO-PEN XL(R); GLAUCOMA; DOGS;
D O I
10.5433/1679-0359.2017v38n6p3647
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in cats. Ten healthy eyes were used in an ex vivo study in which the calibration curve for manometry vs. tonometry was determined by artificially raising the IOP in 5 mmHg increments up to 60 mmHg (10-60 mmHg). Both eyes of 10 anesthetized cats were studied in vivo to compare manometry vs. tonometry. In the ambulatory study, 78 healthy eyes, 7 eyes with glaucoma and 20 eyes with uveitis were evaluated by tonometry, which was performed with topical anesthesia and 1% fluorescein eye drops for the formation of fluorescein semicircles. The correlation coefficient (r(2)) between the manometer and the Kowa HA-2 tonometer was 0.993 and the linear regression equation was y = 0.0915x + 0.0878 in the ex-vivo study. In the in vivo study, the IOP values (mean +/- SD, in mmHg) in manometry were 15.6 +/- 1.1(14.0-17.5) and in tonometry were 15.5 +/- 1.2(13.5-17.2), with no significant difference (P > 0.05) between manometry and tonometry. In ambulatory study, using the Kowa HA-2 tonometer, the IOP values (mean +/- SD, in mmHg) were 15.0 +/- 1.5 (11.8-18.3) for the healthy eyes, 38.4 +/- 8.1(29.6-53.7) for glaucomatous eyes and 10.4 +/- 2.0(5.3-12.2) for eyes with uveitis. There was a strong correlation and accuracy between the IOP values with the manometry and the Kowa HA-2 tonometer. In the ambulatory study the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. We conclude that the Kowa HA-2 tonometer can be used in the measurement of IOP in cats, since it is a practical and accurate method in this species.
引用
收藏
页码:3647 / 3655
页数:9
相关论文
共 50 条
  • [1] Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in dogs
    Andrade, Silvia Franco
    de Andrade, Alexandre Lima
    Kanashiro, Glaucia Prada
    Silva, Danielle Alves
    Barbero, Rafael Cabral
    Pereira Kuhn, Jacqueline Marcussi
    da Silva, Andressa Caroline
    SEMINA-CIENCIAS AGRARIAS, 2016, 37 (02): : 797 - 805
  • [2] Evaluation of the Perkins® handheld applanation tonometer in the measurement of intraocular pressure in dogs and cats
    Andrade, Silvia Franco
    Cremonezi, Tatiana
    Miranda Zachi, Cristiane Aparecida
    Lonchiati, Caroline Ferreira
    Amatuzzi, Juliana Dalarrosa
    Sakamoto, Keila Priscilla
    de Arruda Mello, Paulo Augusto
    VETERINARY OPHTHALMOLOGY, 2009, 12 (05) : 277 - 284
  • [3] Postural Change in Intraocular Pressure: A Comparison of Measurement With a Goldmann Tonometer, Tonopen XL, Pneumatonometer, and HA-2
    Barkana, Yaniv
    JOURNAL OF GLAUCOMA, 2014, 23 (01) : E23 - E28
  • [4] MEASUREMENT OF INTRAOCULAR-PRESSURE WITH A PNEUMATIC APPLANATION TONOMETER
    WEST, CE
    CAPELLA, JA
    KAUFMAN, HE
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1972, 74 (03) : 505 - &
  • [5] Goldmann applanation tonometer error relative to true intracameral Intraocular pressure in vitro and in vivo
    McCafferty, Sean Joesph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Postural change in intraocular preure between sitting and lying body positions - a direct comparison of its measurement with an unmodified Goldmann applanation tonometer, Tonopen XL, pneumatonometer, and HA-2 hand-held applanation tonometer
    Barkana, Yaniv
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [7] Agreement of intraocular pressure measurement by scleral Schiotz and Goldmann applanation tonometer
    Shaikh, Zeba Muzammil
    Rajalakshmi, A. R.
    Nagarajan, Swathi
    Lokeshmaran, A.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] RELIABILITY OF INTRAOCULAR-PRESSURE MEASUREMENT WITH THE GOLDMANN APPLANATION TONOMETER IN EPIDEMIOLOGIC STUDIES
    DIELEMANS, I
    VINGERLING, JR
    HOFMAN, A
    GROBBEE, DE
    DEJONG, PTVM
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (03) : 141 - 144
  • [9] Measurement of the intraocular pressure with the “transpalpebral tonometer” TGDc-01 in comparison with applanation tonometry
    Dirk Sandner
    Andreas Böhm
    Sandra Kostov
    Lutz Pillunat
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 563 - 569
  • [10] Reproducibility of intraocular pressure self-measurement by ICare Home rebound tonometer and comparison with Goldman applanation tonometer
    Gaillard, R.
    Fenolland, J. R.
    Bonnel, S.
    Rosenberg, R.
    Marill, A. F.
    Bostanci, K.
    Giraud, J. M.
    Renard, J. P.
    ACTA OPHTHALMOLOGICA, 2015, 93