Successful Surgical Repair of Acute Quadriceps Tendon Rupture Utilizing Cortical Button Fixation: A Case Report

被引:0
|
作者
Bae, Andrew S. [1 ]
Collins, Devin W. [1 ]
Jardaly, Achraf H. [2 ]
Fernicola, Patrick J. [1 ,2 ]
机构
[1] Jack Hughston Mem Hosp, Dept Orthopaed Surg, Phenix City, AL 36867 USA
[2] Hughston Clin, Dept Sports Med, Columbus, GA 31909 USA
来源
关键词
Orthopedic Procedures; Quadriceps Muscle; Tendons;
D O I
10.12659/AJCR.934238
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Unusual setting of medical care Background: Timely diagnosis and surgical treatment are often needed to restore function of the extensor mechanism after rupture of the quadriceps tendon. Several techniques for quadriceps tendon repair have been reported, including suture anchors and bone tunnels. Cortical button fixation, or the use of an adjustable cortical fixation device, is a local and biomechanically strong internal brace technique used to treat ligament and tendon injuries. This report is of a 69-year-old man who experienced a quadriceps tendon rupture while golfing and underwent a successful surgical repair using cortical button fixation. Case Report: A 69-year-old man sustained an injury after slipping while golfing. He had immediate left knee pain and inability to bear weight. Radiographs demonstrated patella baja with an acute superior pole avulsion fracture of the patella, consistent with rupture of the quadriceps tendon. Surgical repair was discussed. Technique: After soft tissue debridement, the quadriceps tendon was debrided from the frayed and edematous edges. Two Krackowtype stitches were placed with #2 Fibertape and passed through 2 cortical buttons. Two bone tunnels were drilled from the superior to the inferior poles of the patella, bicortically. The cortical button was passed and appropriately tensioned. Conclusions: Although acute quadriceps tendon rupture is commonly treated with transosseous suture repair and suture anchor repair, this report demonstrates that cortical button fixation was a successful procedure with strong biomechanical properties, resulting in the early return of function and range of motion.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Adjustable Cortical Fixation Device for Quadriceps Tendon Repair: A Cadaveric Biomechanical Study
    Gould, Heath P.
    Rate, William R.
    Abbasi, Pooyan
    Mistretta, Katherine L.
    Hammond, Jason W.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (01)
  • [22] Surgical Treatment for Failure of Repair of Patellar and Quadriceps Tendon Rupture With Ipsilateral Hamstring Tendon Graft
    Maffulli, Nicola
    Papalia, Rocco
    Torre, Guglielmo
    Denaro, Vincenzo
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2017, 25 (01): : 51 - 55
  • [23] Simultaneous Bilateral Quadriceps Femoris Tendon Rupture: Case report
    Gunaydin, Pamukcu G.
    Demircan, S.
    Oz, T.
    Otal, Y.
    JOURNAL OF EMERGENCY MEDICINE CASE REPORTS, 2021, 12 (04): : 97 - 99
  • [24] BILATERAL SIMULTANEOUS RUPTURE OF QUADRICEPS TENDON - CASE-REPORT
    NORRIS, MG
    LEVACK, B
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1977, 8 (04): : 315 - 316
  • [25] BILATERAL QUADRICEPS TENDON-RUPTURE - A CASE-REPORT
    KAAR, TK
    OBRIEN, M
    MURRAY, P
    MULLAN, GB
    IRISH JOURNAL OF MEDICAL SCIENCE, 1993, 162 (12) : 502 - 502
  • [26] Acute Distal Triceps Tendon Rupture Repair: Case Presentation and Surgical Technique
    Luthringer, Tyler A.
    Lowe, Dylan T.
    Egol, Kenneth A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 : S18 - S19
  • [27] Repair of Bilateral Quadriceps Tendon Rupture Using a Modified Knotless Suture Anchor and Internal Brace Technique: Surgical Technique and Case Report
    Wang, Xiaoping
    Huang, Daoqiang
    Feng, Weili
    Wu, Weiwei
    Huang, Jian
    Chen, Luyao
    Tu, Yumin
    ORTHOPAEDIC SURGERY, 2022, 14 (09) : 2396 - 2401
  • [28] DIAGNOSIS OF ACUTE RUPTURE OF THE QUADRICEPS TENDON BY MAGNETIC-RESONANCE-IMAGING - A CASE-REPORT
    KUIVILA, TE
    BREMS, JJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (262) : 236 - 241
  • [29] Successful Surgical Repair of Central Slip Rupture in Finger Extensor Tendon
    Hou, Zhongjun
    Zhao, Liping
    Yu, Shengjun
    Xiao, Bo
    Zhou, Juhua
    IN VIVO, 2014, 28 (04): : 599 - 603
  • [30] Intramedullary Cortical Button Repair for Distal Biceps Tendon Rupture: A Single-Center Experience
    Siebenlist, Sebastian
    Schmitt, Andreas
    Imhoff, Andreas B.
    Lenich, Andreas
    Sandmann, Gunther H.
    Braun, Karl F.
    Kirchhoff, Chlodwig
    Biberthaler, Peter
    Buchholz, Arne
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (05): : 418.e1 - 418.e7