Hyperpolarized 129Xe MR Imaging with Balanced Steady-state Free Precession in Spontaneously Breathing Mouse Lungs

被引:6
|
作者
Imai, Fumito [1 ]
Kashiwagi, Ryosuke [1 ]
Imai, Hirohiko [1 ]
Iguchi, Satoshi [1 ]
Kimura, Atsuomi [1 ]
Fujiwara, Hideaki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Med Phys & Engn, Area Med Technol & Sci,Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
balanced steady-state free precession; hyperpolarized Xe-129; MR imaging; mouse lungs; spontaneous breathing; MAGNETIC-RESONANCE; HE-3; VENTILATION; GAS;
D O I
10.2463/mrms.10.33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the characteristics of hyperpolarized (HP) Xe-129 magnetic resonance (MR) imaging obtained from balanced steady-state free precession (SSFP) measurement of mouse lungs, especially under spontaneous breathing, and compared the results with those obtained using traditional spoiled gradient echo (SPGR) method, focusing on improved signal-to-noise ratio (SNR) and reduced total acquisition time. Methods: We calculated magnetization response of the HP Xe-129 gas for the balanced SSFP sequence under spontaneous breathing to derive optimal conditions for the imaging experiment. We then placed an anesthetized mouse in the magnet (9.4T) supplied with oxygen gas and a mixture of HP Xe-129 gas supplied from a continuous-flow hyperpolarizing system. We obtained an axial plane image of the lung through balanced SSFP and SPGR sequences, changing the various magnetic resonance (MR) imaging parameters, and measured the SNR of these images. Results: We demonstrated the clear dependence of image intensity on flip angle and number of shots. The SNR was higher in balanced SSFP than in SPGR and 2.3-fold higher compared at each maximum. In contrast, total acquisition time in balanced SSFP was shortened to about one-eighth that of SPGR using a one-shot acquisition mode. Conclusion: In HP Xe-129 MR imaging of the lung of a spontaneously breathing mouse, balanced SSFP sequence with multi-shot and centric order acquisition provides higher SNR in a shorter acquisition time than SPGR.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [41] Unenhanced MR angiography of the renal arteries with balanced steady-state free precession Dixon method
    Stafford, Randall B.
    Sabati, Mohammad
    Haakstad, Michael J.
    Mahallati, Houman
    Frayne, Richard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 243 - 246
  • [42] Dynamic MR Imaging of the Temporomandibular Joint Using a Balanced Steady-State Free Precession Sequence at 3T
    Yen, P.
    Katzberg, R. W.
    Buonocore, M. H.
    Sonico, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : E24 - E26
  • [43] Assessment of Gas Exchange With Hyperpolarized 129Xe MR Imaging in Mild Asthmatics When Administered a Vasodilator
    Delgado, G. M. Garcia
    Shammi, U.
    Ruppel, M.
    Mummy, D.
    Lu, J.
    Altes, T. A.
    Mugler, J. P., III
    Driehuys, B.
    Thomen, R. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [44] Pulmonary Perfusion and Xenon Gas Exchange in Rats: MR Imaging with Intravenous Injection of Hyperpolarized 129Xe
    Driehuys, Bastiaan
    Moeller, Harald E.
    Cleveland, Zackary I.
    Pollaro, James
    Hedlund, Laurence W.
    RADIOLOGY, 2009, 252 (02) : 386 - 393
  • [45] Pediatric Hyperpolarized 129xe Mr Imaging: Safety And Tolerability In Healthy Children And Cystic Fibrosis Patients
    Walkup, L. L.
    Thomen, R.
    Akinyi, T.
    Ruppert, K.
    Cleveland, Z. I.
    Clancy, J. P.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [46] Quantitative diffusion imaging with steady-state free precession
    Deoni, SCL
    Peters, TM
    Rutt, BK
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 428 - 433
  • [47] Flow effects in balanced steady state free precession imaging
    Markl, M
    Alley, MT
    Elkins, CJ
    Pelc, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 892 - 903
  • [48] Starter sequence for steady-state free precession imaging
    Foxall, DL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 919 - 929
  • [49] Pseudo Steady-State Free Precession for MR-Fingerprinting
    Asslaender, Jakob
    Glaser, Steffen J.
    Hennig, Juergen
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1151 - 1161
  • [50] Phase preparation in steady-state free precession MR elastography
    Rump, Jens
    Warmuth, Carsten
    Braun, Jurgen
    Sack, Ingolf
    MAGNETIC RESONANCE IMAGING, 2008, 26 (02) : 228 - 235