Hyperpolarized 129Xe MR Imaging with Balanced Steady-state Free Precession in Spontaneously Breathing Mouse Lungs

被引:6
|
作者
Imai, Fumito [1 ]
Kashiwagi, Ryosuke [1 ]
Imai, Hirohiko [1 ]
Iguchi, Satoshi [1 ]
Kimura, Atsuomi [1 ]
Fujiwara, Hideaki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Med Phys & Engn, Area Med Technol & Sci,Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
balanced steady-state free precession; hyperpolarized Xe-129; MR imaging; mouse lungs; spontaneous breathing; MAGNETIC-RESONANCE; HE-3; VENTILATION; GAS;
D O I
10.2463/mrms.10.33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the characteristics of hyperpolarized (HP) Xe-129 magnetic resonance (MR) imaging obtained from balanced steady-state free precession (SSFP) measurement of mouse lungs, especially under spontaneous breathing, and compared the results with those obtained using traditional spoiled gradient echo (SPGR) method, focusing on improved signal-to-noise ratio (SNR) and reduced total acquisition time. Methods: We calculated magnetization response of the HP Xe-129 gas for the balanced SSFP sequence under spontaneous breathing to derive optimal conditions for the imaging experiment. We then placed an anesthetized mouse in the magnet (9.4T) supplied with oxygen gas and a mixture of HP Xe-129 gas supplied from a continuous-flow hyperpolarizing system. We obtained an axial plane image of the lung through balanced SSFP and SPGR sequences, changing the various magnetic resonance (MR) imaging parameters, and measured the SNR of these images. Results: We demonstrated the clear dependence of image intensity on flip angle and number of shots. The SNR was higher in balanced SSFP than in SPGR and 2.3-fold higher compared at each maximum. In contrast, total acquisition time in balanced SSFP was shortened to about one-eighth that of SPGR using a one-shot acquisition mode. Conclusion: In HP Xe-129 MR imaging of the lung of a spontaneously breathing mouse, balanced SSFP sequence with multi-shot and centric order acquisition provides higher SNR in a shorter acquisition time than SPGR.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [1] Multiple Breath Washout of Hyperpolarized 129Xe and 3He in Human Lungs With Three-Dimensional Balanced Steady-State Free-Precession Imaging
    Horn, Felix C.
    Rao, Madhwesha
    Stewart, Neil J.
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2288 - 2295
  • [2] Fast measurement of relaxation times by steady-state free precession of 129Xe in carrier agents for hyperpolarized noble gases
    Oregioni, A
    Parizel, N
    de Sousa, PL
    Grucker, D
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) : 1028 - 1032
  • [3] MR imaging of the lungs with hyperpolarized Xe-129 gas
    DeLange, EE
    Brookeman, JR
    Mugler, JP
    Daniel, TM
    Driehuys, B
    Cates, GD
    RADIOLOGY, 1996, 201 : 405 - 405
  • [4] On the application of balanced steady-state free precession to MR microscopy
    Baer, Sebastien
    Oerther, Thomas
    Weigel, Matthias
    Mueller, Angelina
    Hucker, Patrick
    Korvink, Jan G.
    Ko, Cheng-Wen
    Wapler, Matthias C.
    Leupold, Jochen
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (04) : 437 - 447
  • [5] On the application of balanced steady-state free precession to MR microscopy
    Sébastien Bär
    Thomas Oerther
    Matthias Weigel
    Angelina Müller
    Patrick Hucker
    Jan G. Korvink
    Cheng-Wen Ko
    Matthias C. Wapler
    Jochen Leupold
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 437 - 447
  • [6] Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans
    Cleveland, Zackary I.
    Cofer, Gary P.
    Metz, Gregory
    Beaver, Denise
    Nouls, John
    Kaushik, S. Sivaram
    Kraft, Monica
    Wolber, Jan
    Kelly, Kevin T.
    McAdams, H. Page
    Driehuys, Bastiaan
    PLOS ONE, 2010, 5 (08):
  • [7] Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging
    Rao, Madhwesha R.
    Stewart, Neil J.
    Griffiths, Paul D.
    Norquay, Graham
    Wild, Jim M.
    RADIOLOGY, 2018, 286 (02) : 659 - 665
  • [8] Spiral balanced steady-state free precession cardiac imaging
    Nayak, KS
    Hargreaves, BA
    Hu, BS
    Nishimura, DG
    Pauly, JM
    Meyer, CH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1468 - 1473
  • [9] Hyperpolarized 129Xe Functional MR Imaging to Monitor the Response of Human Lungs After Segmental Lipopolysaccharide Challenge
    Kern, A. L.
    Biller, H.
    Klimes, F.
    Voskrebenzev, A.
    Gutberlet, M.
    Rotaermel, A.
    Schoenfeld, C.
    Renne, J.
    Holz, O.
    Wacker, F.
    Vogel-Claussen, J.
    Hohlfeld, J. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [10] Regional fractional ventilation mapping in spontaneously breathing mice using hyperpolarized 129Xe MRI
    Imai, Hirohiko
    Matsumoto, Hironobu
    Miyakoshi, Erika
    Okumura, Shintaro
    Fujiwara, Hideaki
    Kimura, Atsuomi
    NMR IN BIOMEDICINE, 2015, 28 (01) : 24 - 29