An inverse method for mechanical characterization of heterogeneous diseased arteries using intravascular imaging

被引:15
|
作者
Narayanan, Bharath [1 ,2 ]
Olender, Max L. [1 ,3 ]
Marlevi, David [1 ]
Edelman, Elazer R. [1 ,4 ]
Nezami, Farhad R. [1 ,5 ]
机构
[1] MIT, Inst Med Engn & Sci, Cambridge, MA 02139 USA
[2] Ecole Polytech Fed Lausanne, Inst Chem Sci & Engn, CH-1015 Lausanne, Switzerland
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[4] Harvard Med Sch, Brigham & Womens Hosp, Cardiovasc Div, Boston, MA 02115 USA
[5] Harvard Med Sch, Brigham & Womens Hosp, Thorac & Cardiac Surg Div, Boston, MA 02115 USA
关键词
ATHEROSCLEROTIC PLAQUES; ULTRASOUND ELASTOGRAPHY; LOCAL ELASTICITY; STRESS; COMBINATION; RUPTURE; MRI;
D O I
10.1038/s41598-021-01874-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The increasing prevalence of finite element (FE) simulations in the study of atherosclerosis has spawned numerous inverse FE methods for the mechanical characterization of diseased tissue in vivo. Current approaches are however limited to either homogenized or simplified material representations. This paper presents a novel method to account for tissue heterogeneity and material nonlinearity in the recovery of constitutive behavior using imaging data acquired at differing intravascular pressures by incorporating interfaces between various intra-plaque tissue types into the objective function definition. Method verification was performed in silico by recovering assigned material parameters from a pair of vessel geometries: one derived from coronary optical coherence tomography (OCT); one generated from in silico-based simulation. In repeated tests, the method consistently recovered 4 linear elastic (0.1 +/- 0.1% error) and 8 nonlinear hyperelastic (3.3 +/- 3.0% error) material parameters. Method robustness was also highlighted in noise sensitivity analysis, where linear elastic parameters were recovered with average errors of 1.3 +/- 1.6% and 8.3 +/- 10.5%, at 5% and 20% noise, respectively. Reproducibility was substantiated through the recovery of 9 material parameters in two more models, with mean errors of 3.0 +/- 4.7%. The results highlight the potential of this new approach, enabling high-fidelity material parameter recovery for use in complex cardiovascular computational studies.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Influence of aging on mechanical properties of the femoral neck using an inverse method
    Voumard, Benjamin
    Stefanek, Pia
    Pretterklieber, Michael
    Pahr, Dieter
    Zysset, Philippe
    BONE REPORTS, 2022, 17
  • [32] Estimation of mechanical properties of metallic materials using inverse method in SPT
    Wenger, Esteban
    Fierro, Victor
    Ansaldi, Andrea
    Gabarain, Rodrigo
    Alvarez Villar, Nelson
    MATERIA-RIO DE JANEIRO, 2018, 23 (02):
  • [33] A method for 3D reconstruction of coronary arteries using biplane angiography and intravascular ultrasound images
    Bourantas, CV
    Kourtis, IC
    Plissiti, ME
    Fotiadis, DI
    Katsouras, CS
    Papafaklis, MI
    Michalis, LK
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (08) : 597 - 606
  • [34] Characterization of blood velocity in arteries using a combined analytical and Doppler imaging approach
    Sidnawi, Bchara
    Chen, Zhen
    Sehgal, Chandra
    Santhanam, Sridhar
    Wu, Qianhong
    PHYSICAL REVIEW FLUIDS, 2019, 4 (05):
  • [35] Inverse method for imaging a free surface using electrical impedance tomography
    Butler, JE
    Bonnecaze, RT
    CHEMICAL ENGINEERING SCIENCE, 2000, 55 (07) : 1193 - 1204
  • [36] CHARACTERIZATION OF BIPHASE HETEROGENEOUS MEDIA USING A NUMERICAL PROCESSING METHOD
    DELEBARRE, C
    ROUVAEN, JM
    BRUNEEL, C
    FROHLY, J
    JOURNAL OF APPLIED PHYSICS, 1988, 63 (06) : 1846 - 1849
  • [37] Characterizing atherosclerotic tissues: in silico analysis of mechanical properties using intravascular ultrasound and inverse finite element methods
    Latorre, Alvaro T.
    Martinez, Miguel A.
    Pena, Estefania
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [38] AN AUTOMATED METHOD FOR ATHEROSCLEROTIC PLAQUE CHARACTERIZATION AND QUANTIFICATION USING INTRAVASCULAR ULTRASOUND IMAGES
    Athanasiou, L. S.
    Fotiadis, D. I.
    Tsakanikas, V. D.
    Naka, K. K.
    Michalis, L. K.
    ADVANCED TOPICS IN SCATTERING THEORY AND BIOMEDICAL ENGINEERING, 2010, : 63 - 78
  • [39] Statistical Tissue Characterization of Coronary Plaque by ASSOM Using Intravascular Ultrasound Method
    Kubota, Ryosuke
    Kunihiro, Mami
    Suetake, Noriaki
    Uchino, Eiji
    Hashimoto, Genta
    Hiro, Takafumi
    Matsuzaki, Masunori
    PROCEEDINGS OF THE 7TH WSEAS INTERNATIONAL CONFERENCE ON SYSTEM SCIENCE AND SIMULATION IN ENGINEERING (ICOSSSE '08): RECENT ADVANCES IN SYSTEMS SCIENCE AND SIMULATION IN ENGINEERING, 2008, : 85 - +
  • [40] CHARACTERIZATION OF MECHANICAL PROPERTIES BY FINITE ELEMENT METHOD INVERSE ANALYSIS COMBINED WITH INDENTATION TEST
    Isaza, Jesica
    Mariaka, Isabela
    Ramirez, Juan
    DYNA-COLOMBIA, 2013, 80 (179): : 126 - 133