Large cross-sectional area of the umbilical cord as a predictor of fetal macrosomia

被引:39
|
作者
Cromi, A. [1 ]
Ghezzi, F. [1 ]
Di Naro, E. [2 ]
Siesto, G. [1 ]
Bergamini, V. [3 ]
Raio, L. [4 ]
机构
[1] Univ Insubria, Del Ponte Hosp, Dept Obstet & Gynecol, Varese, Italy
[2] Univ Bari, Bari, Italy
[3] Univ Verona, I-37100 Verona, Italy
[4] Univ Bern Inselspital, Bern, Switzerland
关键词
diabetes; estimated fetal weight; macrosomia; ultrasound; umbilical cord; Wharton's jelly;
D O I
10.1002/uog.5183
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To determine whether a large cross-sectional area of the umbilical cord is a predictor of fetal macrosomia. Methods Consecutive Patients of > 34 weeks' gestation, who presented for sonographic examination and who delivered within 4 weeks of the examination, were included in the study. The sonographic cross-sectional areas of the umbilical cord, the umbilical vessels and the Wharton's jelly were measured in a free loop of the umbilical cord. Logistic regression analysis was used to determine significant predictors of macrosomia (actual birth weight > 4000 g and > 4500 g). Fetal biometric parameters (biparietal diameter, abdominal circumference and femur length), sonographic estimated fetal weight and umbilical cord area > 95(th) centile for gestational age were used as covariates. Results During the study period, 1026 patients were enrolled. Fifty-three (5.2%) newborns had a birth weight >4000g, and 22 (2.1%) weighed >4500g. The proportion of cases with a large umbilical cord was significantly higher in the group of macrosomic compared with non-macrosomic infants (54.7% vs. 8.7%, P < 0.0001). Multiple regression models demonstrated an independent contribution of the large cord in the prediction of birth weight > 4000 g and > 4500 g (odds ratio (9S% CI), 20.6 (9.2-45.9) and 4.2 (1.2-17.7), respectively). The sensitivity, specificity and positive and negative predictive values of a sonographic large umbilical cord were 54.7%, 91.3%, 25.4%, and 97.4%, respectively. The combination of abdominal circumference >95(th) centile and large cord predicted 100% of macrosomic infants. The proportion of umbilical cords with a Wharton's jelly area > 95(th) centile for gestation was significantly higher in macrosomic fetuses of diabetic compared with non-diabetic mothers. Conclusions Sonographic assessment of umbilical cord area may improve the prediction of fetal macrosomia. Copyright (c) 2007 ISUOG. Published by John Wiley & Sons, Ltd.
引用
下载
收藏
页码:861 / 866
页数:6
相关论文
共 50 条
  • [1] Ultrasound-measured umbilical cord area predictor of fetal macrosomia
    Lacunza Paredes, Rommel Omar
    REVISTA PERUANA DE GINECOLOGIA Y OBSTETRICIA, 2013, 59 (04): : 247 - 253
  • [2] The cross-sectional area of umbilical cord components in normal pregnancy
    Togni, F. A.
    Junior, E. Araujo
    Vasques, F. A. P.
    Moron, A. F.
    Torloni, M. R.
    Nardozza, L. M. M.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 96 (03) : 156 - 161
  • [3] Comparative study of umbilical cord cross-sectional area in foetuses with isolated single umbilical artery and normal umbilical artery
    Li, Tian-Gang
    Guan, Chong-Li
    Wang, Jian
    Peng, Mei-Juan
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2022, 42 (05) : 935 - 940
  • [4] Fetal hemoglobin in umbilical cord blood in preeclamptic and normotensive pregnancies: A cross-sectional comparative study
    Masoumi, Zahra
    Familari, Mary
    Kallen, Karin
    Ranstam, Jonas
    Olofsson, Per
    Hansson, Stefan R.
    PLOS ONE, 2017, 12 (04):
  • [5] Spinal cord area as a cross-sectional predictor of gait related disability in multiple sclerosis
    McGinley, M.
    Nakamura, K.
    Li, H.
    Weber, M.
    Macaron, G.
    Moss, B.
    Baldassari, L.
    Bermel, R.
    Cohen, J.
    Ontaneda, D.
    MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 152 - 153
  • [6] Reference intervals for the cross sectional area of the umbilical cord during gestation
    Togni, Fernando Alves
    Araujo Junior, Edward
    Moron, Antonio Fernandes
    Augusto, Fisvio
    Vasques, Prado
    Torloni, Maria Regina
    Machado Nardozza, Luciano Marcondes
    Guimaraes Filho, Helio Antonio
    JOURNAL OF PERINATAL MEDICINE, 2007, 35 (02) : 130 - 134
  • [7] Examination of the cross-sectional area of the carpal tunnel on fetal cadavers
    Kondak, Mehtap
    Celep, Merve
    Uluutku, Mehmet Haluk
    EUROPEAN JOURNAL OF ANATOMY, 2023, 27 (04) : 455 - 461
  • [8] A cross-sectional study of umbilical cord blood donor profiles and their influence on umbilical cord blood collection in a Brazilian hospital
    Santos, Sandra Valeria
    Marti, Luciana
    Feitosa Ribeiro, Andreza Alice
    Conti, Fabiana
    Barros, Sonia Maria
    CYTOTHERAPY, 2011, 13 (09) : 1120 - 1127
  • [9] Longitudinal reference range for umbilical cord cross-sectional area in twin pregnancies at 18-32 weeks of gestation
    Fernandes, D. B.
    Liao, A. W.
    Brizot, M. L.
    Francisco, R. P. V.
    Zugaib, M.
    PRENATAL DIAGNOSIS, 2015, 35 (05) : 500 - 505
  • [10] Placental and Umbilical Cord Indices and Their Association with Fetal Distress in Hadiya Zone Public Hospitals, Southern Ethiopia: A Cross-Sectional Study
    Meskele, Simeon
    Mulu, Abay
    GebreMickael, Abinet
    Ena, Lankamo
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 10045 - 10053