Intra- and inter-observer reliability of Cobb angle measurements in patients with adolescent idiopathic scoliosis

被引:14
|
作者
Prestigiacomo, F. G. [1 ]
Hulsbosch, M. H. H. M. [1 ]
Bruls, V. E. J. [1 ]
Nieuwenhuis, J. J. [1 ]
机构
[1] VieCuri Med Ctr, Orthopaed Dept, Venlo, Netherlands
关键词
Intra-observer reliability; Inter-observer reliability; Scoliosis; Radiograph; Cobb angle; INTRAOBSERVER; RADIOGRAPHS;
D O I
10.1007/s43390-021-00398-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The Cobb angle method is used to determine the severity of scoliosis. Therapeutic decisions for adolescent idiopathic scoliosis (AIS) are guided by the Cobb angle. Therefore, high reliability is crucial. The objective of this study was to determine the intra- and inter-observer reliability of the digital Cobb angle measurements and the definition of end vertebrae in patients with AIS. Moreover, the influence of the observer's medical specialty and experience on Cobb angle measurement was evaluated. Methods Intra- and inter-observer reliability of the digital Cobb angle and end vertebrae is assessed in postero-anterior radiographs of 39 patients with AIS. Measurements were performed blinded and twice by six observers, with a two to 3 week interval. Intra- and inter-observer reliability was analysed by means of intraclass correlation coefficients (ICC). Results Both intra- and inter-observer reliability analyses resulted in ICC's higher than 0.864 for the Cobb angle and definition of end vertebrae. In addition, for the observer's experience and medical specialty group the inter-observer ICC's were higher than 0.984. The average inter-observer variability for the Cobb angle were 3 degrees, and 1.1-1.6 levels for the cranial and caudal end vertebrae selection. The variability in measured Cobb angle was 1 degrees for the experience group and 2 degrees for the medical specialty group. Cronbach's alpha varied from 0.990 to 0.996. Bland-Altman plots showed moderate variation with a few outliers. Conclusions The digital Cobb angle measurement as well as the definition of end vertebrae show excellent reliability. According to our results, medical specialty and experience do not affect Cobb angle measurements and definition of end vertebrae.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 50 条
  • [41] INTER-OBSERVER RELIABILITY AND USEFULNESS OF ANTHROPOMETRIC MEASUREMENTS
    SCHOLL, DE
    HAIN, WF
    MULLEN, JL
    CLINICAL RESEARCH, 1983, 31 (02): : A622 - A622
  • [42] INTER-OBSERVER RELIABILITY AND USEFULNESS OF ANTHROPOMETRIC MEASUREMENTS
    SCHOLL, DE
    HAIN, WF
    MULLEN, JL
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1983, 37 (04): : 730 - 730
  • [43] Intra- and Inter-observer Variability of Computed Tomographic Measurements of the Prostate Gland in Neutered Dogs
    Delaude, Alessandro
    Broeckx, Bart J. G.
    Saunders, Jimmy H.
    De Winter, Lauren
    Hillaert, Amber
    Stock, Emmelie
    FRONTIERS IN VETERINARY SCIENCE, 2021, 8
  • [44] Algorithm for Schroth-Curve-Type Classification of Adolescent Idiopathic Scoliosis: An Intra- and Inter-Rater Reliability Study
    Schreiber, Sanja
    Parent, Eric C.
    Kawchuk, Gregory N.
    Hedden, Douglas M.
    CHILDREN-BASEL, 2023, 10 (03):
  • [45] MRI assessment of bone marrow in children with juvenile idiopathic arthritis: intra- and inter-observer variability
    de Horatio, Laura Tanturri
    Damasio, Maria Beatrice
    Barbuti, Domenico
    Bracaglia, Claudia
    Lambot-Juhan, Karen
    Boavida, Peter
    Muller, Lil-Sofie Ording
    Malattia, Clara
    Rava, Lucilla
    Rosendahl, Karen
    Toma, Paolo
    PEDIATRIC RADIOLOGY, 2012, 42 (06) : 714 - 720
  • [46] MRI assessment of bone marrow in children with juvenile idiopathic arthritis: intra- and inter-observer variability
    Laura Tanturri de Horatio
    Maria Beatrice Damasio
    Domenico Barbuti
    Claudia Bracaglia
    Karen Lambot-Juhan
    Peter Boavida
    Lil-Sofie Ording Müller
    Clara Malattia
    Lucilla Ravà
    Karen Rosendahl
    Paolo Tomà
    Pediatric Radiology, 2012, 42 : 714 - 720
  • [47] Talar neck rotation angle in adults with clubfoot deformity: Observed values and intra- and inter-observer reliability using weightbearing CT
    Malhotra, Karan
    Colta, Raul
    Jani, Priyanka
    Haldar, Anil
    Patel, Shelain
    Welck, Matthew
    Cullen, Nicholas
    FOOT AND ANKLE SURGERY, 2024, 30 (03) : 263 - 267
  • [48] Intra- and inter-rater reliabilities and differences of kyphotic angle measurements on ultrasound images versus radiographs for children with adolescent idiopathic scoliosis: a preliminary study
    Tehzeeb Sayed
    Mahdieh Khodaei
    Doug Hill
    Edmond Lou
    Spine Deformity, 2022, 10 : 501 - 507
  • [49] Intra- and inter-observer reliability of a protocol for post mortem evaluation of bruises in Chilean beef carcasses
    Strappini, A. C.
    Frankena, K.
    Metz, J. H. M.
    Kemp, B.
    LIVESTOCK SCIENCE, 2012, 145 (1-3) : 271 - 274
  • [50] Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability
    Lundqvist, Eva
    Segelsjo, Monica
    Andersson, Anna
    Magnusson, Anders
    Biglarnia, Ali-Reza
    ACTA RADIOLOGICA, 2012, 53 (09) : 966 - 972