Based on the refractive angle method of complex refractive index measurement

被引:3
|
作者
Zhang, Qiuzhang [1 ]
Luo, Tianshu [1 ]
机构
[1] Xiamen Univ, Tan Kah Kee Coll, Zhangzhou 363105, Peoples R China
来源
OPTIK | 2018年 / 174卷
关键词
Geometric optics; Light refraction; Complex refractive index; PLASMON RESONANCE SENSOR; ELLIPSOMETRY; ION;
D O I
10.1016/j.ijleo.2018.08.091
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
By studying the real refractive angle of light through the tip of the wedge-shaped absorbing medium, the relationship between the real and imaginary parts of the complex refractive index with the real refractive angle have been obtained. If the refractive index of the medium, the refractive index of the absorbing medium and the incident angle is given, it can be calculated the real refractive angle, however, it is necessary to measure wedge-shaped absorbing medium with two different angles of incidence, by inversion the real and imaginary parts of the refractive index of the absorbing medium by the real refractive angle. Numerical analysis shows that, when the vertex angle is small, the real refractive angle and the vertex angle are approximate linear relationship, and in the case of large vertex angle, the real refractive angle will become flat with the vertex angle. In the case of real parts of the refractive index remains the same, the magnitude of the real refractive angle decreases as the imaginary part of the complex refractive index increases. When the real part and imaginary part ratio of a certain, the real refractive angle is close.
引用
收藏
页码:692 / 697
页数:6
相关论文
共 50 条
  • [21] Refractive index measurement deflectometry for measuring gradient refractive index lens
    Zhang, Zekun
    Wang, Ruiyang
    Zhang, Xinwei
    Ge, Renhao
    Zheng, Wanxing
    Chen, Manwei
    Li, Dahai
    OPTICS EXPRESS, 2024, 32 (07) : 12620 - 12635
  • [22] Measurement of refractive index profile of non-symmetric, complex silica preforms with high refractive index differences
    Probostova, Jana
    Slanicka, Jiri
    Mrazek, Jan
    Podrazky, Ondrej
    Benda, Adam
    Peterka, Pavel
    MICRO-STRUCTURED AND SPECIALTY OPTICAL FIBRES IV, 2016, 9886
  • [23] Liquid Refractive Index Measurement Based on Inverse Raytracing Using an Optical Angle Sensor
    Ohtani, Kozo
    Baba, Mitsuru
    2019 12TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2019), 2019,
  • [24] Novel droplet size and complex refractive index measurement based on rainbow detection
    Pan, Qi
    Chinese Optics Letters, 2012, 10 (SUPPL.2):
  • [25] On measurement of complex refractive index of liquids by diffractive element-based sensor
    Jääskeläinen, A
    Sivennoinen, R
    Peiponen, KE
    Räty, J
    OPTICS COMMUNICATIONS, 2000, 178 (1-3) : 53 - 57
  • [26] METHOD OF REFRACTIVE-INDEX MEASUREMENT FOR TRANSPARENT SUBSTANCES
    ODARICH, VA
    OPTIKA I SPEKTROSKOPIYA, 1974, 37 (04): : 761 - 764
  • [27] A METHOD FOR FINE MEASUREMENT OF REFRACTIVE INDEX DISTRIBUTION IN GLASS
    HATIEGANU, S
    MAZARIEG.MA
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1969, 269 (21): : 1097 - +
  • [28] Refractive Index Measurement Using a Modified Prism Method
    A. I. Yurin
    G. N. Vishnyakov
    V. L. Minaev
    Measurement Techniques, 2023, 66 : 96 - 100
  • [29] Refractive Index Measurement Using a Modified Prism Method
    Yurin, A. I.
    Vishnyakov, G. N.
    Minaev, V. L.
    MEASUREMENT TECHNIQUES, 2023, 66 (02) : 96 - 100
  • [30] Method to determine refractive index by measurement of flat plates
    Johnson, R. Barry
    Curley, Michael J.
    CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL ENGINEERING XX, 2019, 11104