High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE)

被引:0
|
作者
Walter, C
Philippi, G
Westerhausen, R
Kooijman, H
Hoffmann, HG
Busch, HP
机构
[1] Krankenhaus Barmherzigen Bruder, Abt Radiol, Trier, Germany
[2] Univ Trier, Zentrum Neuropsychol Forsch, D-54286 Trier, Germany
[3] Philips Med Syst, MR Clin Sci GMH05, Hamburg, Germany
关键词
MR-angiography; renal arteries; parallel imaging; spatial resolution; randomly segmented central k-space ordering;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare three dimensional contrast enhanced MR angiography with parallel imaging technique (sensitivity encoding) to standard MR angiography technique. Material and Methods: CE-3D MRA of renal arteries was performed in 22 patients (23 examinations) on a 1.5 T MR- scanner (Gyroscan Intera, Philips, Netherlands). For contrast enhanced MRA a single dose of Gd-DTPA (0.1 mmol/kg b.w.) was administered. Group 1: The following standard 3D gradient echo (GE) sequence was performed in 9 of the 22 patients: TR: 4.3 ms, TE: 1.5 ms, flip,angle: 40, 40 slices, scan duration: 19 seconds. A spatial resolution of 1.96 x 1.76 x 3.0 mm(3) (1.76 x 1.76 x 1.5 mm(3) interpolated) was obtained. Group 11: 14 examinations were acquired in 13 patients: TR, TE and flip angle were equal compared to the first protocol. The k-space lines were acquired with CENTRA (contrast-enhanced time robust angiography) and parallel-imaging technique (SENSE). 60 slices were acquired, scan duration was 24 seconds. The spatial resolution of this sequence was 1.19 x 1.08 x 2.0 mm(3) (0,84 x 0,84 x 1,0 mm(3) interpolated). Original images and calculated maximum intensity projection (MIP) images were analysed by two radiologists. Image quality and the visibility of renal arteries were rated on a four-point scale. Results: In the first group the image quality was rated "good" in 8/9 patients. The renal arteries were detected in all cases and rated "good". The anterior and posterior segments were rated,,good" in only 5/9 and the lobar arteries were detectable only in 3 of 9 cases. The interlobar arteries could not be seen in these patients. In the second group the image quality was rated excellent in 5 examinations and good in 9 of 14 examinations. The rating for the renal arteries was excellent in all examinations (14/14). The results of the anterior and posterior segment were as followed: excellent 5/14, good 7/14, insufficient 2/14; the lobar arteries: good 6/14, insufficient 6/14 and not detectable 2/14. Interlobar arteries could be seen in 7/14 examinations, but the quality was insufficient. In 7/ 14 the interlobar arteries could not be detected. Conclusion: The use of parallel imaging technique improves image quality and the delineation of small vessels in renal MRA.
引用
收藏
页码:1244 / 1250
页数:7
相关论文
共 50 条
  • [1] High-resolution contrast-enhanced 3D NM angiography of the renal arteries with parallel imaging (SENSE)
    Reuther, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (12): : 1735 - 1735
  • [2] Value of contrast-enhanced 3D MR angiography of the renal arteries
    T. F. Hany
    T. Pfammatter
    Michaela Schmidt
    D. A. Leung
    J. F. Debatin
    Der Radiologe, 1997, 37 : 547 - 553
  • [3] Value of contrast-enhanced 3D MR angiography of the renal arteries
    Hany, TF
    Pfammatter, T
    Schmidt, M
    Leung, DA
    Debatin, JF
    RADIOLOGE, 1997, 37 (07): : 547 - 553
  • [4] Breath held high resolution 3D contrast-enhanced renal artery MR angiography
    Silverman, JM
    Tyszka, JM
    Sun, Y
    RADIOLOGY, 1997, 205 : 278 - 278
  • [5] On improving temporal and spatial resolution of 3D contrast-enhanced body MR angiography with parallel imaging
    Chen, Q
    Quijano, CV
    Mai, VM
    Krishnamoorthy, SK
    Li, W
    Storey, P
    Edelman, RR
    RADIOLOGY, 2004, 231 (03) : 893 - 899
  • [6] Ultrafast contrast-enhanced 3D MR angiography of the aorta and renal arteries in apnoea
    Hany, TF
    Pfammatter, T
    Schmidt, M
    Leung, DA
    Debatin, JF
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (05): : 397 - 405
  • [7] High resolution contrast enhanced MR-angiography of the hand arteries: preliminary experiences
    Krause, U
    Pabst, T
    Kenn, W
    Hahn, D
    VASA-JOURNAL OF VASCULAR DISEASES, 2002, 31 (03): : 179 - 184
  • [8] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [9] High-Resolution 3D Unenhanced ECG-Gated Respiratory-Navigated MR Angiography of the Renal Arteries: Comparison With Contrast-Enhanced MR Angiography
    Mohrs, Oliver K.
    Petersen, Steffen E.
    Schulze, Thomas
    Zieschang, Michael
    Kuex, Harald
    Schmitt, Peter
    Bergemann, Sabine
    Kauczor, Hans-Ulrich
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1423 - 1428
  • [10] Advances in Contrast-Enhanced MR Angiography of the Renal Arteries
    Leiner, Tim
    Michaely, Henrik
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (04) : 561 - +