A Novel Clinical Test of Recognition Reaction Time in Healthy Adults
被引:38
|
作者:
Eckner, James T.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USAUniv Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USA
Eckner, James T.
[1
]
Richardson, James K.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USAUniv Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USA
Richardson, James K.
[1
]
Kim, Hogene
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48108 USAUniv Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USA
Kim, Hogene
[2
]
Lipps, David B.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48108 USAUniv Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USA
Lipps, David B.
[2
]
Ashton-Miller, James A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48108 USA
Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48108 USAUniv Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USA
Ashton-Miller, James A.
[2
,3
]
机构:
[1] Univ Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48108 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48108 USA
[3] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48108 USA
We evaluated a clinical "go/no-go" reaction time test (recognition RTclin) that is portable and does not require a computer, and used it to quantify the effect of age on recognition RTclin test scores. Fifty-two healthy adults 19-83 years old completed simple and recognition RT, testing. Simple RTclin was measured as the elapsed time from initial release of a suspended vertical shaft by the examiner until its arrest by participant pinch grip. Recognition RTclin was similar except that a light on the apparatus randomly illuminated in 50% of the trials to signal the participant to arrest the device. To help interpret the lach results, we partitioned them into premovement time (PMT) and movement time (MT) using an optoelectronic camera system that is not ordinarily part of the RTclin test. Recognition RTclin, scores were significantly slower than simple RTclin scores, with 71% of the prolongation attributable to Pm-r. While simple RTclin test scores correlated with age, recognition RTclin scores did not. A strong negative association between recognition RTclin accuracy and age was found. Recognition RTclin is feasible to measure in healthy adults and appears to represent a portable, computer-independent measure of cognitive processing speed and inhibitory capacity. Potential applications include assessment of brain injury, dementing illness, medication side effects, fall risk, and safe driving.