Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate

被引:21
|
作者
Khongpet, Wanpen [1 ]
Pencharee, Somkid [2 ]
Puangpila, Chanida [1 ]
Hartwell, Supaporn Kradtap [3 ]
Lapanantnoppakhun, Somchai [1 ]
Jakmunee, Jaroon [1 ,4 ,5 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Lab Analyt Instrumentat & Electrochem Innovat, Chiang Mai 50200, Thailand
[2] Ubon Ratchathani Univ, Dept Phys, Fac Sci, Ubon Ratchathani 34190, Thailand
[3] Xavier Univ, Dept Chem, 3800 Victory Pkwy, Cincinnati, OH 45207 USA
[4] Chiang Mai Univ, Fac Sci, Ctr Environm Sci, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Fac Sci, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
关键词
Microfluidic; Hydrodynamic sequential injection HSI; Phosphate; Molybdenum blue; Soil; MOLYBDENUM BLUE REACTION; WASTE-WATER; SILICATE; ORTHOPHOSPHATE; PHOSPHORUS; NITRATE; MANIFOLD; SOILS;
D O I
10.1016/j.talanta.2017.09.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic hydrodynamic sequential injection (HSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1-6 mg P L-1 was obtained. The detection limit was 0.1 mg L-1. The system is compact (5.0 mm thick, 80 mm wide x 140 min long), durable, portable, cost-effective, and consumes little amount of chemicals (83 mu L each of molybdate and ascorbic acid, 133 mu L of the sample solution and 1.7 mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2-107.3. The results obtained agreed well with those of the batch spectrophotometric method.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 50 条
  • [41] An Environmentally Friendly Compact Microfluidic Hydrodynamic Sequential Injection System Using Curcuma putii Maknoi & Jenjitt. Extract as a Natural Reagent for Colorimetric Determination of Total Iron in Water Samples
    Namjan, Maneerat
    Kaewwonglom, Natcha
    Dechakiatkrai Theerakarunwong, Chonlada
    Jakmunee, Jaroon
    Khongpet, Wanpen
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2023, 2023
  • [42] Determination of Thiamine as a Complex with 11-Molybdobismutho(III) phosphate in Sequential Injection Lab-at-valve System
    Vishnikin, A. B.
    Miekh, Y. V.
    Denisenko, T. A.
    Kozhemiaka, V. G.
    Vishnikina, V. Yu.
    Al-Shwaiyat, M. K. E. A.
    Bazel, Ya. R.
    Andruch, V.
    METHODS AND OBJECTS OF CHEMICAL ANALYSIS, 2018, 13 (02): : 55 - 63
  • [43] Automated Sequential-injection Chemiluminescence Determination of Glucosamine Sulphate via Luminol-Hydrogen Peroxide System
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (10) : 1246 - 1252
  • [44] Spectrophotometric determination of phosphate and silicate by sequential injection using molybdenum blue chemistry
    Galhardo, CX
    Masini, JC
    ANALYTICA CHIMICA ACTA, 2000, 417 (02) : 191 - 200
  • [45] Automated IR determination of petroleum products in water based on sequential injection analysis
    Falkova, Marina
    Vakh, Christina
    Shishov, Andrey
    Zubakina, Ekaterina
    Moskvin, Aleksey
    Moskvin, Leonid
    Bulatov, Andrey
    TALANTA, 2016, 148 : 661 - 665
  • [46] Automated sequential injection fluorimetric determination and dissolution studies of Ergotamine Tartrate in pharmaceuticals
    Legnerová, Z
    Sklenárová, H
    Solich, P
    TALANTA, 2002, 58 (06) : 1151 - 1155
  • [47] Auto-Calibration and Micro-Flow Injection Procedure Based on Automated Hydrodynamic System for Spectrophotometric Determination of Cobalt
    Camarillo E, R. M.
    Padilla M, J. A.
    Garcia M, J. A.
    Ocon D, C. A.
    Reyes C, Ch.
    Camarillo E, J. M.
    Rodriguez R, R.
    EMERGING CHALLENGES FOR EXPERIMENTAL MECHANICS IN ENERGY AND ENVIRONMENTAL APPLICATIONS, 2017, : 255 - 263
  • [48] Microfluidic sequential injection analysis in a short capillary
    Du, Wen-Bin
    Fang, Qun
    Fang, Zhao-Lun
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6404 - 6410
  • [49] A linear gradient sequential injection chromatography method exploiting programmable fluidics for the determination of three methylxanthines
    Chorti, Parthena
    Ntousikou, Melina
    Economou, Anastasios
    TALANTA, 2019, 202 : 514 - 519
  • [50] Sequential injection-capillary immunoassay system for determination of sialoglycoconjugates
    Hartwell, Supaporn Kradtap
    Wannaprom, Napaporn
    Kongtawelert, Prachya
    Grudpan, Kate
    TALANTA, 2009, 79 (05) : 1209 - 1215