Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate

被引:21
|
作者
Khongpet, Wanpen [1 ]
Pencharee, Somkid [2 ]
Puangpila, Chanida [1 ]
Hartwell, Supaporn Kradtap [3 ]
Lapanantnoppakhun, Somchai [1 ]
Jakmunee, Jaroon [1 ,4 ,5 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Lab Analyt Instrumentat & Electrochem Innovat, Chiang Mai 50200, Thailand
[2] Ubon Ratchathani Univ, Dept Phys, Fac Sci, Ubon Ratchathani 34190, Thailand
[3] Xavier Univ, Dept Chem, 3800 Victory Pkwy, Cincinnati, OH 45207 USA
[4] Chiang Mai Univ, Fac Sci, Ctr Environm Sci, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Fac Sci, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
关键词
Microfluidic; Hydrodynamic sequential injection HSI; Phosphate; Molybdenum blue; Soil; MOLYBDENUM BLUE REACTION; WASTE-WATER; SILICATE; ORTHOPHOSPHATE; PHOSPHORUS; NITRATE; MANIFOLD; SOILS;
D O I
10.1016/j.talanta.2017.09.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic hydrodynamic sequential injection (HSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1-6 mg P L-1 was obtained. The detection limit was 0.1 mg L-1. The system is compact (5.0 mm thick, 80 mm wide x 140 min long), durable, portable, cost-effective, and consumes little amount of chemicals (83 mu L each of molybdate and ascorbic acid, 133 mu L of the sample solution and 1.7 mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2-107.3. The results obtained agreed well with those of the batch spectrophotometric method.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 50 条
  • [1] A compact hydrodynamic sequential injection system for consecutive online determination of phosphate and ammonium
    Khongpet, Wanpen
    Pencharee, Somkid
    Puangpila, Chanida
    Hartwell, Supaporn Kradtap
    Lapanantnoppakhun, Somchai
    Jakmunee, Jaroon
    MICROCHEMICAL JOURNAL, 2019, 147 : 403 - 410
  • [2] Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
    Somnam, Sarawut
    Grudpan, Kate
    Jakmunee, Jaroon
    SPECTROSCOPY LETTERS, 2008, 41 (05) : 221 - 227
  • [3] Determination of Nitrite and Nitrate in Water Samples by an Automated Hydrodynamic Sequential Injection Method
    Somnam, Sarawut
    Jakmunee, Jaroon
    Grudpan, Kate
    Lenghor, Narong
    Motomizu, Shoji
    ANALYTICAL SCIENCES, 2008, 24 (12) : 1599 - 1603
  • [4] Determination of Nitrite and Nitrate and Nitrate in Water Samples by an Automated Hydrodynamic Sequential Injection Method
    Sarawut Somnam
    Jaroon Jakmunee
    Kate Grudpan
    Narong Lenghor
    Shoji Motomizu
    Analytical Sciences, 2008, 24 : 1599 - 1603
  • [5] Hydrodynamic Sequential Injection with Stopped-flow Procedure for Consecutive Determination of Phosphate and Silicate in Wastewater
    Somnam, Sarawut
    Motomizu, Shoji
    Grudpan, Kate
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2014, 41 (03): : 606 - 617
  • [6] A fast sequential injection analysis system for the simultaneous determination of ammonia and phosphate
    Frank, C
    Schroeder, F
    Ebinghaus, R
    Ruck, W
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 31 - 38
  • [7] A Fast Sequential Injection Analysis System for the Simultaneous Determination of Ammonia and Phosphate
    Carsten Frank
    Friedhelm Schroeder
    Ralf Ebinghaus
    Wolfgang Ruck
    Microchimica Acta, 2006, 154 : 31 - 38
  • [8] Determination of phosphate in urine by sequential injection analysis
    B. M. Simonet
    F. Grases
    J. G. March
    Fresenius' Journal of Analytical Chemistry, 2001, 369 : 96 - 102
  • [9] Determination of phosphate in urine by sequential injection analysis
    Simonet, BM
    Grases, F
    March, JG
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (01): : 96 - 102
  • [10] An automated sequential injection analysis system for the determination of trace endotoxin levels in water
    Samanta, G
    Zhang, SM
    Dasgupta, P
    PDA JOURNAL OF PHARMACEUTICAL SCIENCE AND TECHNOLOGY, 2003, 57 (01) : 12 - 24