Mechanical Characterization of a Viscoelastic Disc for Lumbar Total Disc Replacement

被引:12
|
作者
Benzel, Edward C. [1 ]
Lieberman, Isador H. [2 ]
Ross, E. Raymond [3 ]
Linovitz, Raymond J. [4 ]
Kuras, James [5 ]
Zimmers, Kari [5 ]
机构
[1] Cleveland Clin, Neurol Inst, Dept Neurosurg, Cleveland, OH 44195 USA
[2] Texas Hlth Presbyterian Hosp Plano, Texas Back Inst, Scoliosis & Spine Tumor Ctr, Plano, TX 75093 USA
[3] Salford Royal NHS Fdn Trust Univ Teaching Hosp, Salford M6 8HD, Lancs, England
[4] CORE Orthopaed Med Grp, Encinitas, CA 92024 USA
[5] AxioMed Spine Corp, Garfield Hts, OH 44125 USA
关键词
lumbar spine; disc arthroplasty; viscoelastic; disc degeneration; total disc replacement; intervertebral disc; artificial disc; INVESTIGATIONAL DEVICE EXEMPTION; CHARITE(TM) ARTIFICIAL DISC; ADJACENT-SEGMENT DEGENERATION; SPINE MOTION SEGMENTS; INTERBODY FUSION; NUCLEUS PULPOSUS; PRODISC-II; FOLLOW-UP; ONE-LEVEL; TOTAL HIP;
D O I
10.1115/1.4003536
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A viscoelastic artificial disc may more closely replicate normal stiffness characteristics of the healthy human disc compared with first-generation total disc replacement (TDR) devices, which do not utilize viscoelastic materials and are based on a ball and socket design that does not allow loading compliance. Mechanical testing was performed to characterize the durability and range of motion (ROM) of an investigational viscoelastic TDR (VTDR) device for the lumbar spine, the Freedom (R) Lumbar Disc. ROM data were compared with data reported for the human lumbar disc in the clinical literature. Flexibility and stiffness of the VTDR in compression, rotation, and flexion/extension were within the parameters associated with the normal human lumbar disc. The device constrained motion to physiologic ranges and replicated normal stress/strain dynamics. No mechanical or functional failures occurred within the loads and ROM experienced by the human disc. Fatigue testing of the worst case VTDR device size demonstrated a fatigue life of 50 years of simulated walking and 240 years of simulated significant bends in both flexion/extension and lateral bending coupled with axial rotation, with no functional failures. These results indicate that the VTDR evaluated in this mechanical study is durable and has the ability to replicate the stiffness and mechanics of the natural, healthy human lumbar disc. [DOI: 10.1115/1.4003536]
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Experimental Evaluation of Vertebral Strain in Lumbar Total Disc Replacement
    Semitela, A.
    Fonseca, F.
    Completo, A. M. G.
    EXPERIMENTAL MECHANICS, 2020, 60 (01) : 119 - 128
  • [32] Total lumbar disc replacement - Different results for different levels
    Siepe, Christoph J.
    Mayer, H. Michael
    Heinz-Leisenheimer, Matthias
    Korge, Andreas
    SPINE, 2007, 32 (07) : 782 - 790
  • [33] LUMBAR SPINE CAPSULE STRAIN AFTER TOTAL DISC REPLACEMENT
    Takigawa, Tomoyuki
    Orias, Alejandro A. Espinoza
    An, Howard S.
    Simon, Peter
    Sugisaki, Keizo
    Natarajan, Raghu N.
    Wimmer, Markus A.
    Andersson, Gunnar B. J.
    Inoue, Nozomu
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 475 - 476
  • [34] Anterior discectomy and total disc replacement for three patients with multiple recurrent lumbar disc herniations
    Glenn, Jamieson S.
    Yaker, Joseph
    Guyer, Richard D.
    Ohnmeiss, Donna D.
    SPINE JOURNAL, 2011, 11 (09): : E1 - E6
  • [35] Total disc replacement for lumbar degenerative disc disease: single centre 20 years experience
    Carlo Formica
    Andrea Zanirato
    Stefano Divano
    Marco Basso
    Luca Cavagnaro
    Mattia Alessio Mazzola
    Valerio Gaetano Vellone
    Maddalena Mastrogiacomo
    Pedro Berjano
    Lamberto Felli
    Matteo Formica
    European Spine Journal, 2020, 29 : 1518 - 1526
  • [36] Total disc replacement surgery for symptomatic degenerative lumbar disc disease: a systematic review of the literature
    van den Eerenbeemt, Karin D.
    Ostelo, Raymond W.
    van Royen, Barend J.
    Peul, Wilco C.
    van Tulder, Maurits W.
    EUROPEAN SPINE JOURNAL, 2010, 19 (08) : 1262 - 1280
  • [37] Total disc replacement
    Vital, J. -M.
    Boissiere, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (01) : S1 - S14
  • [38] Measurement error of lumbar total disc replacement range of motion
    Lim, MR
    Loder, RT
    Huang, RC
    Lyman, S
    Zhang, K
    Sama, A
    Papadopoulos, EC
    Warner, K
    Girardi, FP
    Cammisa, FP
    SPINE, 2006, 31 (10) : E291 - E297
  • [39] Experimental Evaluation of Vertebral Strain in Lumbar Total Disc Replacement
    A. Semitela
    F. Fonseca
    A.M.G. Completo
    Experimental Mechanics, 2020, 60 : 119 - 128
  • [40] Barriers to and Budget Impact of Lumbar Total Disc Replacement Utilization
    Sandhu, Faheem
    Blumenthal, Scott
    Grunch, Betsy
    Kimball, Bent
    Ferko, Nicole
    Hollmann, Sarah
    SPINE, 2017, 42 (24) : S112 - S114