Mechanical Characterization of a Viscoelastic Disc for Lumbar Total Disc Replacement

被引:12
|
作者
Benzel, Edward C. [1 ]
Lieberman, Isador H. [2 ]
Ross, E. Raymond [3 ]
Linovitz, Raymond J. [4 ]
Kuras, James [5 ]
Zimmers, Kari [5 ]
机构
[1] Cleveland Clin, Neurol Inst, Dept Neurosurg, Cleveland, OH 44195 USA
[2] Texas Hlth Presbyterian Hosp Plano, Texas Back Inst, Scoliosis & Spine Tumor Ctr, Plano, TX 75093 USA
[3] Salford Royal NHS Fdn Trust Univ Teaching Hosp, Salford M6 8HD, Lancs, England
[4] CORE Orthopaed Med Grp, Encinitas, CA 92024 USA
[5] AxioMed Spine Corp, Garfield Hts, OH 44125 USA
关键词
lumbar spine; disc arthroplasty; viscoelastic; disc degeneration; total disc replacement; intervertebral disc; artificial disc; INVESTIGATIONAL DEVICE EXEMPTION; CHARITE(TM) ARTIFICIAL DISC; ADJACENT-SEGMENT DEGENERATION; SPINE MOTION SEGMENTS; INTERBODY FUSION; NUCLEUS PULPOSUS; PRODISC-II; FOLLOW-UP; ONE-LEVEL; TOTAL HIP;
D O I
10.1115/1.4003536
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A viscoelastic artificial disc may more closely replicate normal stiffness characteristics of the healthy human disc compared with first-generation total disc replacement (TDR) devices, which do not utilize viscoelastic materials and are based on a ball and socket design that does not allow loading compliance. Mechanical testing was performed to characterize the durability and range of motion (ROM) of an investigational viscoelastic TDR (VTDR) device for the lumbar spine, the Freedom (R) Lumbar Disc. ROM data were compared with data reported for the human lumbar disc in the clinical literature. Flexibility and stiffness of the VTDR in compression, rotation, and flexion/extension were within the parameters associated with the normal human lumbar disc. The device constrained motion to physiologic ranges and replicated normal stress/strain dynamics. No mechanical or functional failures occurred within the loads and ROM experienced by the human disc. Fatigue testing of the worst case VTDR device size demonstrated a fatigue life of 50 years of simulated walking and 240 years of simulated significant bends in both flexion/extension and lateral bending coupled with axial rotation, with no functional failures. These results indicate that the VTDR evaluated in this mechanical study is durable and has the ability to replicate the stiffness and mechanics of the natural, healthy human lumbar disc. [DOI: 10.1115/1.4003536]
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Total lumbar disc replacement
    Mayer, HM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (08): : 1029 - 1037
  • [2] Lumbar Total Disc Replacement
    Gill, Norman W.
    Konitzer, Lisa N.
    Hoppes, Carrie W.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (03): : 200 - 200
  • [3] Lumbar total disc replacement
    Grob, D.
    ORTHOPADE, 2009, 38 (01): : 93 - 99
  • [4] Total Disc Replacement in Lumbar Degenerative Disc Diseases
    Park, Chun Kun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 58 (05) : 401 - 411
  • [5] The current status of lumbar total disc replacement
    Huang, RC
    Sandhu, HS
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2004, 35 (01) : 33 - +
  • [6] Lumbar total disc replacement: A numerical study
    Di Mascio, Valeriano
    Bellini, Chiara M.
    Galbusera, Fabio
    Raimondi, Manuela T.
    Brayda-Bruno, Marco
    Assietti, Roberto
    JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS, 2010, 8 (02) : 97 - 101
  • [7] The implications of constraint in lumbar total disc replacement
    Huang, RC
    Girardi, FP
    Cammisa, FP
    Wright, TM
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (04): : 412 - 417
  • [8] Lumbar Total Disc Replacement: Current Usage
    Franco, Daniel
    Largoza, Garrett
    Montenegro, Thiago S.
    Gonzalez, Glenn A.
    Hines, Kevin
    Harrop, James
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2021, 32 (04) : 511 - 519
  • [9] The impact of total lumbar disc replacement on segmental and total lumbar lordosis
    Cakir, B
    Richter, M
    Käfer, W
    Puhl, W
    Schmidt, R
    CLINICAL BIOMECHANICS, 2005, 20 (04) : 357 - 364
  • [10] Total disc replacement with the CHARITE artificial disc was as effective as lumbar interbody fusion
    Herkowitz, HN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (05): : 1168 - 1168