Energy and exergy analysis of NH3/CO2 cascade refrigeration system with subcooling in the low-temperature cycle based on an auxiliary loop of NH3 refrigerants

被引:17
|
作者
Chen, Xiaonan [1 ]
Yang, Qichao [1 ]
Chi, Weikai [1 ]
Zhao, Yuanyang [1 ]
Liu, Guangbin [1 ]
Li, Liansheng [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Electromech Engn, Qingdao 266100, Peoples R China
基金
中国国家自然科学基金;
关键词
Cascade refrigeration system; Subcooling; Energy and exergy analysis; Mechanical subcooling; INTERNAL HEAT-EXCHANGER; PERFORMANCE; OPTIMIZATION; ECONOMIZER; PLANT;
D O I
10.1016/j.egyr.2022.01.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a NH3/CO2 cascade refrigeration system that sets an auxiliary refrigeration loop in the high-temperature cycle to increase the subcooling degree in the low-temperature cycle (CRSS). Based on the basic principles of thermodynamics, a mathematical model is established and theoretical simulation is carried out to obtain the influence of key parameters on the cycle performance. Compared with the conventional cascade refrigeration system (CCRS), the conclusions find that there exists an optimal condensation temperature of low-temperature cycle (T-MC.opt) to maximize COP. The maximum COP of CRSS is 4.58% higher than that of CCRS when the subcooling degree is 10 degrees C. The maximum exergy efficiency is 0.391, increasing by 4.40%. With the increase of the subcooling degree, both the COP and the T-MC. opt of CRSS increase. When the subcooling degree increases from 5 degrees C to 15 degrees C, the performance increment increases from 2.73% to 6.00%. When the evaporation temperature of the system changes, both the COP and exergy efficiency decreases slightly and it is found that the performance is better when the evaporation temperature is lower when condensation temperature is kept constant. Besides, the discharge temperature of the NH3 compressor in CRSS can be reduced by 9.9 degrees C when the evaporation temperature is -30 degrees C. (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:1757 / 1767
页数:11
相关论文
共 50 条
  • [21] Experimental study on the performance of a twin-screw CO2 compressor in NH3/CO2 cascade refrigeration system
    Wang, B. M.
    Xing, Z. W.
    Wu, H. G.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A8) : 1141 - 1146
  • [22] A FEASIBILITY ANALYSIS OF REPLACING THE STANDARD AMMONIA REFRIGERATION DEVICE WITH THE CASCADE NH3/CO2 REFRIGERATION DEVICE IN THE FOOD INDUSTRY
    Jankovich, Dennis
    Osman, Kresimir
    THERMAL SCIENCE, 2015, 19 (05): : 1821 - 1833
  • [23] Thermodynamic Analysis and Comparison on Low Temperature CO2-NH3 Cascade Refrigeration Cycle
    查世彤
    马一太
    申江
    李敏霞
    Transactions of Tianjin University, 2003, (03) : 252 - 255
  • [24] Exergetic, economic and environmental (3E) analyses, and multiobjective optimization of a CO2/NH3 cascade refrigeration system
    Aminyavari, Mehdi
    Najafi, Behzad
    Shirazi, Alec
    Rinaldi, Fabio
    APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) : 42 - 50
  • [25] A Study of Solid CO2/NH3 and NH3/H2O by XPS
    Dillingham, T.R.
    Cornelison, D.M.
    Surface Science Spectra, 2002, 9 (01): : 12 - 20
  • [26] NH3 oxidation and NO reduction by NH3 in N2/Ar and CO2 atmospheres
    Alzueta, Maria U.
    Mercader, Victor D.
    Gimenez-Lopez, Jorge
    Bilbao, Rafael
    FUEL, 2023, 353
  • [27] TEMPERATURE AND CONCENTRATION OF CO2 AND NH3 IN BROILER TRUCKS
    EHINGER, F
    GSCHWINDT, B
    ARCHIV FUR GEFLUGELKUNDE, 1978, 42 (04): : 139 - 144
  • [28] A superior catalyst for low-temperature NO reduction with NH3
    Qi, GS
    Yang, RT
    CHEMICAL COMMUNICATIONS, 2003, (07) : 848 - 849
  • [29] CO2/NH3 systems [1]
    Pearson, S. Forbes
    ASHRAE Journal, 2002, 44 (12)
  • [30] ABSORPTION OF CO2 BY NH3 SOLUTIONS
    DELANCEY, GB
    WU, KO
    CHEMICAL ENGINEERING SCIENCE, 1979, 34 (01) : 148 - 150