Investigation of pulsed low dose rate radiotherapy using dynamic arc delivery techniques

被引:19
|
作者
Ma, C-M [1 ]
Lin, M. H. [1 ]
Dai, X. F. [2 ]
Koren, Sion [1 ]
Klayton, T. [1 ]
Wang, L. [1 ]
Li, J. S. [1 ]
Chen, L. [1 ]
Price, R. A. [1 ]
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
[2] Union Hosp, Ctr Canc, Tongji Med Coll, Wuhan, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 14期
关键词
RATE RADIATION-THERAPY; CLINICAL IMPLEMENTATION; RETREATMENT STRATEGY; RATE BRACHYTHERAPY; BREAST-CANCER; IRRADIATION; PHOTON;
D O I
10.1088/0031-9155/57/14/4613
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There has been no consensus standard of care to treat recurrent cancer patients who have previously been irradiated. Pulsed low dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while still providing significant tumor control for recurrent cancers. This work investigates the dosimetry feasibility of PLDR treatment using dynamic arc delivery techniques. Five treatment sites were investigated in this study including breast, pancreas, prostate, head and neck, and lung. Dynamic arc plans were generated using the Varian Eclipse system and the RapidArc delivery technique with 6 and 10 MV photon beams. Each RapidArc plan consisted of two full arcs and the plan was delivered five times to achieve a daily dose of 200 cGy. The dosimetry requirement was to deliver approximately 20 cGy/arc with a 3 min interval to achieve an effective dose rate of 6.7 cGy min(-1). Monte Carlo simulations were performed to calculate the actual dose delivered to the planning target volume (PTV) per arc taking into account beam attenuation/scattering and intensity modulation. The maximum, minimum and mean doses to the PTV were analyzed together with the dose volume histograms and isodose distributions. The dose delivery for the five plans was validated using solid water phantoms inserted with an ionization chamber and film, and a cylindrical detector array. Two intensity-modulated arcs were used to efficiently deliver the PLDR plans that provided conformal dose distributions for treating complex recurrent cancers. For the five treatment sites, the mean PTV dose ranged from 18.9 to 22.6 cGy/arc. For breast, the minimum and maximum PTV dose was 8.3 and 35.2 cGy/arc, respectively. The PTV dose varied between 12.9 and 27.5 cGy/arc for pancreas, 12.6 and 28.3 cGy/arc for prostate, 12.1 and 30.4 cGy/arc for H&N, and 16.2 and 27.6 cGy/arc for lung. Advanced radiation therapy can provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent cancers, which can be delivered using dynamic arc delivery techniques with ten full arcs and an effective dose rate of 6.7 +/- 4.0 cGy min(-1).
引用
收藏
页码:4613 / 4626
页数:14
相关论文
共 50 条
  • [1] Investigation of the linear accelerator low dose rate mode for pulsed low-dose-rate radiotherapy delivery
    Abdelgawad, Mahmoud H.
    Eldib, Ahmed A.
    Elsayed, Tamer M.
    Ma, C. M. Charlie
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (06):
  • [2] IMRT for Pancreas and Prostate Cancer Using Pulsed Low Dose Rate Delivery Techniques
    Li, J.
    Lang, J.
    Wang, P.
    Kang, S.
    Lin, M.
    Chen, X.
    Guo, M.
    Chen, F.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [3] External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: Planning and delivery
    Tyagi, Neelam
    Yang, Kai
    Sandhu, Raminder
    Yan, Di
    Park, Sean S.
    Chen, Peter Y.
    Marples, Brian
    [J]. MEDICAL PHYSICS, 2013, 40 (01)
  • [4] Dosimetric Evaluation for Pulsed Low Dose Rate Radiation Therapy Using RapidArc Delivery Techniques
    Ma, C.
    Lin, M.
    Wang, L.
    Price, R.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [5] External Beam Pulsed Low Dose Radiotherapy Using Volumetric Modulated Arc Therapy: Planning, Delivery and Verification
    Tyagi, N.
    Yang, K.
    Sandhu, R.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3997 - 3997
  • [6] Pulsed low dose-rate radiotherapy: radiobiology and dosimetry
    Ma, C. M. Charlie
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03):
  • [7] Comparison of Pulsed Low Dose Rate and Conventional Radiotherapy Using An In-Vivo Model
    Panetta, J.
    Cvetkovic, D.
    Chen, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E728 - E729
  • [8] Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low-dose rate delivery techniques
    Li, Jie
    Lang, Jinyi
    Wang, Pei
    Kang, Shengwei
    Lin, Mu-han
    Chen, Xiaoming
    Chen, Fu
    Guo, Ming
    Chen, Lili
    Charlie, Chang-Ming
    [J]. MEDICAL DOSIMETRY, 2014, 39 (04) : 330 - 336
  • [9] Use of Pulsed Low-Dose Rate Radiotherapy in Refractory Malignancies
    Yan, Jing
    Yang, Ju
    Yang, Yang
    Ren, Wei
    Liu, Juan
    Gao, Shanbao
    Li, Shuangshuang
    Kong, Weiwei
    Zhu, Lijing
    Yang, Mi
    Qian, Xiaoping
    Liu, Baorui
    [J]. TRANSLATIONAL ONCOLOGY, 2018, 11 (01): : 175 - 181
  • [10] Treatment Planning Criteria and Evaluation for Pulsed Low Dose Rate Radiotherapy
    Ma, C.
    Lin, M.
    Li, J.
    Kang, S.
    Chen, L.
    Price, R.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E626 - E626