High-efficiency 3He proportional counter for the detection of delayed neutrons

被引:11
|
作者
Loaiza, DJ [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
D O I
10.1016/S0168-9002(98)01059-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The characteristics of a high-efficiency He-3 proportional counter for the measurement of beta(i)-delayed neutrons have been examined. The detection system required for this experiment needs to meet some stringent requirements such as high-efficiency, low dead time, and gamma-insensitivity. The He-3 counter described here meets all these requirements. This detection system consists of an array of 20 He-3 tubes embedded in polyethylene. The principal operating characteristic of this proportional counter is its high efficiency. The absolute efficiency, determined with an Am/Li source, is 29.04% +/- 0.6%. The system's dead time is 0.46 +/- 0.02 mu s. It is also displacement insensitive within a range of 10 cm. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:43 / 46
页数:4
相关论文
共 50 条
  • [21] 3HE-NE-CH4 MIXTURES IN PROPORTIONAL COUNTER FOR THERMAL NEUTRONS
    KROHN, VE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 853 - &
  • [22] 3He spin filter for neutrons
    Batz, M
    Baessler, S
    Heil, W
    Otten, EW
    Rudersdorf, D
    Schmiedeskamp, J
    Sobolev, Y
    Wolf, M
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2005, 110 (03): : 293 - 298
  • [23] USE OF ASSOCIATED PARTICLES METHOD FOR DETERMINING DETECTION EFFICIENCY OF D(D N)3HE NEUTRONS
    GREIL, A
    TRUTZSCH.K
    KERNENERGIE, 1969, 12 (02): : 68 - &
  • [24] Liquid 3He Detectors for Neutrons
    Villano, A. N.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2024, 216 (1-2) : 371 - 377
  • [25] ANALYSIS OF TRITIUM AND 3He TRACKS USING A MASS SPECTROMETER AND PROPORTIONAL COUNTER.
    Mamyrin, B.A.
    Akulov, Yu.A.
    Khabarin, L.V.
    Yudenich, V.S.
    Soviet physics. Technical physics, 1983, 28 (06): : 690 - 692
  • [26] SCATTERING OF POLARIZED NEUTRONS BY 3HE
    BUSSER, FW
    DUBENKROPP, H
    NIEBERGALL, F
    SINRAM, K
    NUCLEAR PHYSICS A, 1969, A129 (03) : 666 - +
  • [27] Characterisation of 3He proportional counters
    Ravazzani, A.
    Para, A. Foglio
    Jaime, R.
    Looman, M.
    Ferrer, M. Marin
    Peerani, P.
    Schillebeeckx, P.
    RADIATION MEASUREMENTS, 2006, 41 (05) : 582 - 593
  • [28] PRECISION MEASUREMENT OF THERMAL NEUTRON BEAM DENSITIES USING A 3HE PROPORTIONAL COUNTER
    ALSNIELS.J
    BAHNSEN, A
    BROWN, WK
    NUCLEAR INSTRUMENTS & METHODS, 1967, 50 (02): : 181 - &
  • [29] A novel method to measure low flux ambient thermal neutrons with 3He proportional counters
    Zeng, Z. M.
    Gong, H.
    Yue, Q.
    Li, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 866 : 242 - 247
  • [30] HIGH-RESOLUTION, HIGH-EFFICIENCY PROPORTIONAL COUNTER X-RAY CAMERA
    ONGE, RNS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 333 - 333