Shape and Enhancement Analysis as a Useful Tool for the Presentation of Blood Hemodynamic Properties in the Area of Aortic Dissection

被引:5
|
作者
Polanczyk, Andrzej [1 ]
Piechota-Polanczyk, Aleksandra [2 ]
Stefanczyk, Ludomir [3 ]
Strzelecki, Michal [4 ]
机构
[1] Main Sch Fire Serv, PL-01629 Warsaw, Poland
[2] Jagiellonian Univ, Dept Med Biotechnol, PL-30387 Krakow, Poland
[3] Med Univ Lodz, Dept Radiol & Diagnost Imaging, PL-90153 Lodz, Poland
[4] Lodz Univ Technol, Inst Elect, PL-93005 Lodz, Poland
关键词
aortic dissection; brightness analysis; enhancement analysis; image processing; STENT-GRAFT; PERFUSION; GEOMETRY; STRESS; MODEL; TEAR;
D O I
10.3390/jcm9051330
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to create a mathematical approach for blood hemodynamic description with the use of brightness analysis. Medical data was collected from three male patients aged from 45 to 65 years with acute type IIIb aortic dissection that started proximal to the left subclavian artery and involved the renal arteries. For the recognition of wall dissection areas Digital Imaging and Communications in Medicine (DICOM) data were applied. The distance from descending aorta to the diaphragm was analyzed. Each time Feret (D-F) and Hydraulic (D-Hy) diameter were calculated. Moreover, an average brightness (B-AV) was analyzed. Finally, to describe blood hemodynamic in the area of aortic wall dissection, mathematical function combining difference in brightness value and diameter for each computed tomography (CT) scan was calculated. The results indicated that D-F described common duct more accurately compare to D-Hy. While, D-Hy described more accurately true and false ducts. Each time when connection of true and false duct appeared, true duct had lower brightness compare to common duct and false duct. Moreover, false duct characterized with higher brightness compare to common duct. In summary, the proposed algorithm mimics changes in brightness value for patients with acute type IIIb aortic dissection.
引用
收藏
页数:18
相关论文
共 48 条
  • [21] Spatial Configuration of Abdominal Aortic Aneurysm Analysis as a Useful Tool for the Estimation of Stent-Graft Migration
    Polanczyk, Andrzej
    Piechota-Polanczyk, Aleksandra
    Stefanczyk, Ludomir
    Strzelecki, Michal
    DIAGNOSTICS, 2020, 10 (10)
  • [22] Systolic aortic pressure-time area is a useful index describing arterial wave properties in rats with diabetes
    Ru-Wen Chang
    Chun-Yi Chang
    Ming-Shiou Wu
    Hsi-Yu Yu
    Jian-Ming Luo
    Yih-Sharng Chen
    Fang-Yue Lin
    Liang-Chuan Lai
    Chih-Hsien Wang
    Kuo-Chu Chang
    Scientific Reports, 5
  • [23] Systolic aortic pressure-time area is a useful index describing arterial wave properties in rats with diabetes
    Chang, Ru-Wen
    Chang, Chun-Yi
    Wu, Ming-Shiou
    Yu, Hsi-Yu
    Luo, Jian-Ming
    Chen, Yih-Sharng
    Lin, Fang-Yue
    Lai, Liang-Chuan
    Wang, Chih-Hsien
    Chang, Kuo-Chu
    SCIENTIFIC REPORTS, 2015, 5
  • [24] CFD Reconstruction of Blood Hemodynamic Based on a Self-made Algorithm in Patients with Acute Type IIIb Aortic Dissection Treated with TEVAR Procedure
    Polanczyk, A.
    Piechota-Polanczyk, A.
    Neumayer, Ch
    Huk, I
    IUTAM SYMPOSIUM ON RECENT ADVANCES IN MOVING BOUNDARY PROBLEMS IN MECHANICS, 2019, 34 : 75 - 84
  • [25] 3D morphometric analysis of ascending aorta as an adjunctive tool to predict type A acute aortic dissection
    Saade, Wael
    Vinciguerra, Mattia
    Romiti, Silvia
    Macrina, Francesco
    Frati, Giacomo
    Miraldi, Fabio
    Greco, Ernesto
    JOURNAL OF THORACIC DISEASE, 2021, 13 (06) : 3443 - 3457
  • [26] Quantitative analysis of renal blood flow during thoracic endovascular aortic repair in type B aortic dissection using syngo iFlow
    Fang, Kun
    Zhao, Jiawei
    Luo, Mingyao
    Xue, Yunfei
    Wang, Hui
    Ye, Luming
    Zhang, Xuelan
    Zheng, Liancun
    Shu, Chang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (08) : 3726 - 3734
  • [27] The effect of beta-blockers on hemodynamic parameters in patient-specific blood flow simulations of type-B aortic dissection: a virtual study
    Abazari, Mohammad Amin
    Rafieianzab, Deniz
    Soltani, M.
    Alimohammadi, Mona
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [28] The effect of beta-blockers on hemodynamic parameters in patient-specific blood flow simulations of type-B aortic dissection: a virtual study
    Mohammad Amin Abazari
    Deniz Rafiei
    M. Soltani
    Mona Alimohammadi
    Scientific Reports, 11
  • [29] A Software Tool for the Measurement of the Aortic Annulus Area by Means of Computed Tomography Image Analysis for the Planning of Transcatheter Aortic Valve Replacement (TAVR)
    Hervas, Gloria Campos
    Cisnal, Agustin Fernandez
    Garcia-Bias, Sergio
    Minana, Gema
    Valero, Ernesto
    Sanchis, Juan
    Moratal, David
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [30] TCT-3-D analysis of blood flow hemodynamics in aortic dissection: A new framework for guiding therapeutic interventions
    Kasirajan, Karthikeshwar
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 108M - 108M