Large Diameter Tunnel, to Expedite Consent Decree Pipeline

被引:0
|
作者
Farnsworth, Jeff [1 ]
Bennett, David [2 ]
机构
[1] Kimley Horn & Associates Inc, 601 Northwest Loop 410,Suite 350, San Antonio, TX 78216 USA
[2] Freese & Nichols Inc, 9601 McAllister Fwy,Suite 1008, San Antonio, TX 78216 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The San Antonio metropolitan area has experienced sustained growth for decades, putting increased pressure on existing wastewater infrastructure. In June 2013, the San Antonio Water System (SAWS) approved a settlement agreement with the U.S. Environmental Protection Agency (EPA) that requires significant improvements to the SAWS wastewater system over a 10-year period to reduce sanitary sewer overflows (SSOs). This work includes the targeted replacement and rehabilitation of an aging infrastructure system that consists of over 5,200 miles of sewer pipe. One such pipeline is an existing 48-inch concrete trunk sewer which currently operates at capacity during dry periods and during periods of minimal rain, routinely experiences SSOs of 50,000 to 100,000 gallons or more. SAWS has identified the replacement of this critical sewer as one of its highest priorities, initiating design of a six-mile segment of 60- to 78-inch sewer to increase the current capacity. As a key component of the EPA consent order, this project was time-critical. Numerous challenges existed along this six-mile alignment, each of which had significant potential schedule impacts: narrow corridor through U.S. Military installation for over a mile; pipeline depths between 30 and 40 feet; construction under two Department of Transportation roadways and a municipal overpass; and alignment adjacent to a major waterway (Salado Creek) where historic artifacts, flood plain, and tree coverage were likely to require mitigation. In one example, a 4,000-foot tunnel was designed, over 30-feet deep, in a 25-foot easement, that was installed between transmission and distribution power lines, on a U.S. Military installation. This 94 1/2 -inch tunnel was installed via micro-tunneling, for a 78-inch fiberglass reinforced pipe (FRP) sewer carrier pipe. This paper will focus on four tunnels such as the tunnel mentioned above, each of which was designed and installed in locations that would eliminate the need for mitigation. In each location, special considerations were incorporated into the tunnel design related to depths, soil strata, reduction of time limiting impacts, and reduction of SSOs.
引用
收藏
页码:546 / 554
页数:9
相关论文
共 50 条
  • [21] GENZYME SIGNS CONSENT DECREE WITH US
    不详
    CHEMICAL & ENGINEERING NEWS, 2010, 88 (22) : 33 - 33
  • [22] LARGE-DIAMETER PIPELINE PROTECTED WITH POLYETHYLENE COATING
    ODONNELL, JP
    OIL & GAS JOURNAL, 1978, 76 (26) : 150 - 152
  • [23] Benefits of Performance Based Large Diameter Pipeline Rehabilitation
    La Hee, Samantha
    Mihm, Mark
    Koch, Jeremy
    Tillberg, Art
    PIPELINES 2018: CONDITION ASSESSMENT, CONSTRUCTION, AND REHABILITATION, 2018, : 671 - 677
  • [24] Large-diameter coiled-tubing as pipeline
    不详
    JOURNAL OF PETROLEUM TECHNOLOGY, 1997, 49 (06): : 604 - 605
  • [25] Large-diameter coiled-tubing as pipeline
    Gulf of Suez Petroleum Co
    JPT, Journal of Petroleum Technology, 1997, 49 (06): : 604 - 605
  • [26] Closed-hybrid-segment for large diameter tunnel
    Tanaka, Yukitaka
    Uemura, Shunro
    Kanoh, Isamu
    Ito, Soichi
    NKK Technical Review, 1988, (54): : 60 - 68
  • [27] Avoiding Tunnel Vision in Large Diameter Sewer Rehabilitation
    Bell, Robert E., Jr.
    Ranasinghe, Pubudu
    Melsew, Getachew
    PIPELINES 2019: CONDITION ASSESSMENT, CONSTRUCTION, AND REHABILITATION, 2019, : 24 - 31
  • [28] Design of Tunnel Inspection Robot for Large Diameter Sewers
    Seet, G.
    Yeo, S. H.
    Law, W. C.
    Burhan
    Wong, C. Y.
    Sapari, S.
    Liau, K. K.
    INTERNATIONAL CONFERENCE ON ROBOTICS AND SMART MANUFACTURING (ROSMA2018), 2018, 133 : 984 - 990
  • [29] CONSENT DECREE PROCEDURE: THE NEW PAYMENT PROCESS
    Isabel Blanco, Ana
    Montesinos, Ana
    REVISTA BOLIVIANA DE DERECHO, 2016, 22 : 290 - 299
  • [30] OPERATION OF THE CONSENT DECREE IN THE MOTION PICTURE INDUSTRY
    不详
    YALE LAW JOURNAL, 1942, 51 (07): : 1175 - 1195