Amperometric sensing of sulfite using a gold electrode coated with ordered mesoporous carbon modified with nickel hexacyanoferrate

被引:24
|
作者
Preecharueangrit, Supatcha [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,4 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
关键词
Sulfite; Ordered mesoporous carbon; Nickel hexacyanoferrate; Amperometric detection; Flow injection; FLOW-INJECTION ANALYSIS; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSOR; ION CHROMATOGRAPHY; SULFUR-DIOXIDE; NANOPARTICLES; ACID; FOOD; NANOCOMPOSITE; NANOTUBES;
D O I
10.1016/j.jelechem.2017.11.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric sulfite sensor was fabricated based on nickel hexacyanoferrate (NiHCF) electrodeposited on a layer of ordered mesoporous carbon covering on a gold electrode surface (NiHCF/OMC/Au). The prepared NiHCF/OMC/Au displayed good electrocatalytic activity towards the oxidation of sulfite. The sulfite response was determined at an optimal applied potential of 0.40 V vs Ag/AgCl in a flow injection analysis system. Under optimum conditions, the sensor has a linear response in the 2.5 mu M to 50 mM sulfite concentration range and a 2.5 mu M limit of detection (at an S/N ratio of 3). The electrode has a high operational stability, can be used up to 104 times (with a RSD of 5.9%), and a good electrode-to-electrode repeatability (with an RSD of <7.0%, for n = 6). It was applied, in the flow injection mode, to analyze sulfite in vermicelli, instant noodles, noodles, and macaroni. Recoveries of spiked samples ranged of from 80 +/- 1 to 108 +/- 2%, and the results agreed well with the Monier-Williams AOAC official method.
引用
收藏
页码:150 / 159
页数:10
相关论文
共 50 条
  • [41] Amperometric glucose-sensing electrode based on colloidal gold/glucose oxidase-modified glassy carbon
    Yabuki, S
    Mizutani, F
    DENKI KAGAKU, 1996, 64 (12): : 1256 - 1258
  • [42] Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode
    Bai, Jing
    Ndamanisha, Jean Chrysostome
    Liu, Lin
    Yang, Li
    Guo, Liping
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (12) : 2251 - 2256
  • [43] Electrochemical behaviors and determination of isoniazid at ordered mesoporous carbon modified electrode
    Yan, Xue
    Bo, Xiangjie
    Guo, Liping
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02): : 837 - 842
  • [44] Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode
    Jing Bai
    Jean Chrysostome Ndamanisha
    Lin Liu
    Li Yang
    Liping Guo
    Journal of Solid State Electrochemistry, 2010, 14 : 2251 - 2256
  • [45] Electrochemical determination of toxic ractopamine at an ordered mesoporous carbon modified electrode
    Yang, Xiao
    Feng, Bo
    Yang, Peng
    Ding, Yonglan
    Chen, Yi
    Fei, Junjie
    FOOD CHEMISTRY, 2014, 145 : 619 - 624
  • [46] Electrochemical Morphine Sensing Using Gold Nanoparticles Modified Carbon Paste Electrode
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10): : 5066 - 5081
  • [47] Non-enzymatic amperometric glucose sensing on CuO/mesoporous TiO2 modified glassy carbon electrode
    Ali, Muhammad
    Mir, Sadullah
    Ahmed, Safeer
    RSC ADVANCES, 2023, 13 (37) : 26275 - 26286
  • [48] Selective electrochemical sensing of calcium dobesilate based on an ordered mesoporous carbon-modified pyrolytic graphite electrode
    Hu, Guangzhi
    Ma, Yonggen
    Guo, Yong
    Shao, Shijun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 633 (01) : 264 - 267
  • [49] Voltammetric and amperometric determination of sulfite using an aluminum electrode modified by nickel pentacyanonitrosylferrate film - Application to the analysis of some real samples
    Pournaghi-Azar, MH
    Hydarpour, M
    Dastangoo, H
    ANALYTICA CHIMICA ACTA, 2003, 497 (1-2) : 133 - 141
  • [50] Electrocatalytic Oxidation and Determination of Sulfite with a Novel Copper-Cobalt Hexacyanoferrate Modified Carbon Paste Electrode
    Siroueinejad, Arash
    Abbaspour, Abdolkarim
    Shamsipur, Mojtaba
    ELECTROANALYSIS, 2009, 21 (12) : 1387 - 1393