Amperometric sensing of sulfite using a gold electrode coated with ordered mesoporous carbon modified with nickel hexacyanoferrate

被引:24
|
作者
Preecharueangrit, Supatcha [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,4 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
关键词
Sulfite; Ordered mesoporous carbon; Nickel hexacyanoferrate; Amperometric detection; Flow injection; FLOW-INJECTION ANALYSIS; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSOR; ION CHROMATOGRAPHY; SULFUR-DIOXIDE; NANOPARTICLES; ACID; FOOD; NANOCOMPOSITE; NANOTUBES;
D O I
10.1016/j.jelechem.2017.11.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric sulfite sensor was fabricated based on nickel hexacyanoferrate (NiHCF) electrodeposited on a layer of ordered mesoporous carbon covering on a gold electrode surface (NiHCF/OMC/Au). The prepared NiHCF/OMC/Au displayed good electrocatalytic activity towards the oxidation of sulfite. The sulfite response was determined at an optimal applied potential of 0.40 V vs Ag/AgCl in a flow injection analysis system. Under optimum conditions, the sensor has a linear response in the 2.5 mu M to 50 mM sulfite concentration range and a 2.5 mu M limit of detection (at an S/N ratio of 3). The electrode has a high operational stability, can be used up to 104 times (with a RSD of 5.9%), and a good electrode-to-electrode repeatability (with an RSD of <7.0%, for n = 6). It was applied, in the flow injection mode, to analyze sulfite in vermicelli, instant noodles, noodles, and macaroni. Recoveries of spiked samples ranged of from 80 +/- 1 to 108 +/- 2%, and the results agreed well with the Monier-Williams AOAC official method.
引用
收藏
页码:150 / 159
页数:10
相关论文
共 50 条
  • [1] Amperometric sensing of ascorbic acid by using a glassy carbon electrode modified with mesoporous carbon nanorods
    Li, Xiuxiu
    Liu, Jingju
    Sun, Mimi
    Sha, Tianze
    Bo, Xiangjie
    Zhou, Ming
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [2] Amperometric sensing of ascorbic acid by using a glassy carbon electrode modified with mesoporous carbon nanorods
    Xiuxiu Li
    Jingju Liu
    Mimi Sun
    Tianze Sha
    Xiangjie Bo
    Ming Zhou
    Microchimica Acta, 2018, 185
  • [3] Amperometric Detection of Nitrite Using Chitosan Protected Nickel Hexacyanoferrate Nanoparticles Modified Glassy Carbon Electrode
    Sophia, S. Jancy
    Devi, S.
    Pandian, K.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 : S366 - S368
  • [4] Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor
    Yang, Yongfeng
    Yan, Yun
    Chen, Xinfang
    Zhai, Wenying
    Xu, Yuehua
    Liu, Youqin
    ELECTROCATALYSIS, 2014, 5 (04) : 344 - 353
  • [5] Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor
    Yongfeng Yang
    Yun Yan
    Xinfang Chen
    Wenying Zhai
    Yuehua Xu
    Youqin Liu
    Electrocatalysis, 2014, 5 : 344 - 353
  • [6] Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode
    Cai, CX
    Xue, KH
    Zhou, YM
    Yang, H
    TALANTA, 1997, 44 (03) : 339 - 347
  • [7] Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
    Alamo, Lori Shayne T.
    Tangkuaram, Tanin
    Satienperakul, Sakchai
    TALANTA, 2010, 81 (4-5) : 1793 - 1799
  • [8] Amperometric determination of hydrazine using a CuS-ordered mesoporous carbon electrode
    Srinidhi, G.
    Sudalaimani, S.
    Giribabu, K.
    Basha, S. J. Sardhar
    Suresh, C.
    MICROCHIMICA ACTA, 2020, 187 (06)
  • [9] Amperometric determination of hydrazine using a CuS-ordered mesoporous carbon electrode
    G. Srinidhi
    S. Sudalaimani
    K. Giribabu
    S.J. Sardhar Basha
    C. Suresh
    Microchimica Acta, 2020, 187
  • [10] Amperometric determination of inositol based on electrocatalytic oxidation on a glass carbon electrode modified by nickel hexacyanoferrate films
    Yang, YH
    Zhao, QR
    Wang, ZJ
    Yang, MH
    ANALYTICAL LETTERS, 2006, 39 (02) : 361 - 372