A New Two-Port Network Model-Based Pilot Protection for AC Transmission Lines

被引:25
|
作者
Liu, Shiming [1 ]
Zhang, Lu Liang [2 ]
Fu, Chuanshun [1 ]
Jiang, Lin [3 ]
机构
[1] Shandong Univ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan 250061, Shandong, Peoples R China
[2] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Peoples R China
[3] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3BX, Merseyside, England
基金
中国国家自然科学基金;
关键词
Power transmission lines; Transmission line measurements; Transmission line matrix methods; Circuit faults; Current measurement; Voltage measurement; Synchronization; Pilot protection; transmission line; sequence components theory; two-port network; transmission network parameters; CURRENT DIFFERENTIAL PROTECTION; IMPEDANCE; SCHEME; RELAY;
D O I
10.1109/TPWRD.2019.2904310
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional pilot protections used for EHV/UHV ac transmission lines require data synchronization between the two terminals of transmission line, and their performances are affected by the line capacitive charging current and load conditions. To tackle these problems, this paper proposes a new pilot protection scheme based on two-port network model of ac transmission lines. The new protection scheme calculates the two-port network parameters from the online measurements via the sequence components method, and then compares the solved parameters with their setting values to distinguish the internal and external faults. It does not require the data synchronization between two terminals of the transmission line. Moreover, its performance is not affected by the line capacitive charging current and load conditions. The applicability of the proposed scheme for series compensated lines is also analyzed. Effectiveness and accuracy of the proposed protection scheme have been verified by simulation tests.
引用
收藏
页码:473 / 482
页数:10
相关论文
共 50 条
  • [21] Time-domain two-port representation of some nonuniform two-conductor transmission lines
    Maffucci, A
    Miano, G
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 2002, 49 (11): : 1639 - 1645
  • [22] A pilot protection based on low frequency component model for HVDC transmission lines
    Han, Ke
    Chen, Yu
    Ma, Ruizhi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (07) : 1466 - 1477
  • [23] A Novel Pilot Protection for HVDC Transmission Lines Based on Model Error Function
    Li Dong
    Jin Xing-fu
    ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 1878 - +
  • [24] Direct AC/AC Conversion Based Single-phase Hybrid Distribution Transformer and Its Relaxed Two-port Network Modeling
    Wang Y.
    Cai G.
    Liu C.
    Guo D.
    Zhang H.
    Zhu B.
    Dianwang Jishu/Power System Technology, 2020, 44 (08): : 3029 - 3037
  • [25] A cascaded two-port network model for the analysis of harmonic chain-based energy harvesters
    Bonnin, Michele
    Traversa, Fabio L.
    Bonani, Fabrizio
    2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [27] Pilot protection method of half-wavelength AC transmission lines based on random matrix theory
    Tang, Yutao
    Shu, Hongchun
    He, Kai
    Wang, Guanxue
    Liu, Litao
    Han, Yiming
    Dai, Yue
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [28] Post-measurement simulation-based pilot protection of AC transmission lines in wind farms
    Shu, Hongchun
    Guan, Cheng
    Dai, Yue
    Tang, Yutao
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 241
  • [29] A new multiport measurement-method using a two-port network analyzer
    Lenk, F
    Doerner, R
    2005 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, VOLS 1-4, 2005, : 1663 - 1666
  • [30] New type of transmission line pilot protection based on model identification
    Suonan, Jiale
    Yang, Cheng
    Yang, Zhongli
    Shen, Liming
    Jiao, Zaibin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (24): : 30 - 34