Development of rapid oral bacteria detection apparatus based on dielectrophoretic impedance measurement method

被引:66
|
作者
Hamada, R. [1 ,2 ]
Suehiro, J. [2 ]
Nakano, M. [2 ]
Kikutani, T. [3 ]
Konishi, K. [4 ]
机构
[1] Panason Healthcare Co Ltd, R&D Ctr, Toon, Ehime 7910395, Japan
[2] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, Dept Elect & Elect Engn, Nishi Ku, Fukuoka 8190395, Japan
[3] Nippon Dent Univ Sch Life Dent, Grad Sch Life Dent, Div Clin Oral Rehabil, Chiyoda Ku, Tokyo 1028158, Japan
[4] Nippon Dent Univ Sch Life Dent Tokyo, Dept Microbiol, Chiyoda Ku, Tokyo 1028159, Japan
关键词
ASPIRATION PNEUMONIA; SELECTIVE DETECTION; ACQUIRED PNEUMONIA; ELDERLY-PATIENTS; CARE; COLONIZATION; INFECTION; CELLS; ELECTROPERMEABILIZATION; PLAQUE;
D O I
10.1049/iet-nbt.2010.0011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a bacteria detection apparatus based on dielectrophoretic impedance measurement (DEPIM) method was demonstrated for rapid evaluation of oral hygiene. The authors integrated a micro electrode chip on which bacteria were captured by dielectrophoresis (DEP), an AC voltage source to induce DEP force, and an impedance measurement circuit to a portable instrument that enables rapid and automated oral bacterial inspection in hospitals and clinics. Special considerations have been made on effects of high electrical conductivity of oral samples on DEP force and DEPIM results. It was shown experimentally and theoretically that using a higher electric field frequency for the DEP bacteria trap and the impedance measurement could realise DEPIM application to bacteria inspection from oral samples with higher conductivity. Based on these investigations, the authors optimised the frequency condition of the DEPIM suitable for inspecting an oral sample along with the design and development of a portable DEPIM apparatus for on-site inspection of oral bacteria. Under the optimised frequency condition, DEPIM results were in good agreement with the conventional culture method showing significant applicability of the DEPIM apparatus for practical rapid oral bacteria inspection.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [21] Impedance method for rapid detection of total counts of bacteria and fungi in bottled purified water
    Huang, JC
    Yang, JW
    Lai, WD
    Song, MD
    Feng, D
    Lin, JY
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (04) : 719 - 721
  • [22] Improvement of dielectrophoretic impedance measurement method by bacterial concentration utilizing negative dielectrophoresis
    Hamada, R.
    Takayama, H.
    Shonishi, Y.
    Hisajima, T.
    Mao, L.
    Nakano, M.
    Suehiro, J.
    SENSORS & THEIR APPLICATIONS XVI, 2011, 307
  • [23] Impedance-Based Detection of Bacteria
    Furst, Ariel L.
    Francis, Matthew B.
    CHEMICAL REVIEWS, 2019, 119 (01) : 700 - 726
  • [24] Point-of-care detection of Tannerella forsythia using an antigen-antibody assisted dielectrophoretic impedance measurement method
    Ishii, Yoshihito
    Imamura, Kentaro
    Kikuchi, Yuichiro
    Miyagawa, Satoshi
    Hamada, Ryo
    Sekino, Jin
    Sugito, Hiroki
    Ishihara, Kazuyuki
    Saito, Atsushi
    MICROBIAL PATHOGENESIS, 2015, 82 : 37 - 42
  • [25] METHOD FOR RAPID DETECTION OF CYANOGENIC BACTERIA
    CASTRIC, KF
    CASTRIC, PA
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 45 (02) : 701 - 702
  • [26] Spectrophotometric Method for Rapid Detection of Bacteria
    Li Dong-Yang
    Ru Shi-Ping
    Wu Jian
    Ying Yi-Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (04) : 573 - 576
  • [27] Rapid microbead-based DNA detection using dielectrophoresis and impedance measurement
    Nakano, Michihiko
    Ding, Zhenhao
    Kasahara, Hiromichi
    Suehiro, Junya
    EPL, 2014, 108 (02)
  • [28] Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria
    Yang, Liju
    Bashir, Rashid
    BIOTECHNOLOGY ADVANCES, 2008, 26 (02) : 135 - 150
  • [29] AC electrokinetics assisted impedance biosensors for rapid bacteria detection
    Ho, Yi-Tse
    Pan, Chun-Liang
    Sheu, Jeng-Tzong
    Wang, Yu-Kuo
    Wu, Tung-Kung
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 49 - 52
  • [30] Development and application of a bioluminescence atp assay method for rapid detection of coliform bacteria
    Tanaka, H
    Shinji, T
    Sawada, K
    Monji, Y
    Seto, S
    Yajima, M
    Yagi, O
    WATER RESEARCH, 1997, 31 (08) : 1913 - 1918