Projection extension for region of interest imaging in cone-beam CT

被引:17
|
作者
Wiegert, J
Bertram, M
Netsch, T
Wulff, J
Weese, J
Rose, G
机构
[1] Philips Res Labs Aachen, D-52066 Aachen, Germany
[2] Univ Lubeck, Inst Signal Proc, D-23538 Lubeck, Germany
[3] Philips Res Labs Hamburg, D-22335 Hamburg, Germany
关键词
ROI imaging; truncated projections; flat X-ray detector; cone-beam computed tomography; head imaging;
D O I
10.1016/j.acra.2005.04.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. For 3D X-ray imaging during interventions, changes of the imaged object are often restricted to a small part of the field of view, suggesting region of interest (ROI) imaging by irradiating this area only. In this article, we present a novel method for extension of truncated projections in order to avoid truncation artifacts in C-arm based 3D ROI imaging. Materials and Methods. The method makes use of prior knowledge by combining forward projections of a previously acquired, nontruncated 3D reference image with the truncated ROI projections. Rigid registration between the two datasets is achieved by using a technique based on local cross-correlation. To account for a gray value mismatch between the two data sets due to, e.g., differing beam quality and different contributions of scattered radiation, a linear gray level transformation is applied to the forward-projected reference data. Results. The performance of different gray value transformation schemes is systematically assessed by means of numerical simulations. For various simulated scenarios, the best performing transformation has been identified, providing practical guidelines for selecting a scheme depending on the origin of the gray-level mismatch. Experiments prove the high performance of the developed method. Conclusion. The presented technique enables almost artifact-free 3D ROI imaging during interventions. This actually allows for repeated scans at low dose and enables intraprocedural imaging of large objects even with a small detector. However, applicability of the method is limited to scenarios where direct access to a reference image, e.g., a prior CT scan, is available.
引用
收藏
页码:1010 / 1023
页数:14
相关论文
共 50 条
  • [21] CT projection transform theory for circular cone-beam image reconstruction
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2008, 8 (1264-1267):
  • [22] Rectification for cone-beam projection and backprojection
    Riddell, Cyril
    Trousset, Yves
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 950 - 962
  • [23] Compressed Sensing based Image Reconstruction with Projection Recovery for Limited Angle Cone-Beam CT Imaging
    Xie, Shoulie
    Huang, Weimin
    Yang, Tao
    Wu, Dajun
    Liu, Huiying
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1307 - 1310
  • [24] Region-of-interest image reconstruction in circular cone-beam microCT
    Cho, Seungryong
    Bian, Junguo
    Pelizzari, Charles A.
    Chen, Chin-Tu
    He, Tong-Chuan
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2007, 34 (12) : 4923 - 4933
  • [25] Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT
    Yoo, B.
    Pua, R.
    Kim, J.
    Cho, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [26] Cone-beam CT based dose calculation in the thorax region
    Kaplan, L. P.
    Hoffmann, L.
    Moller, D. S.
    Elstrom, U. V.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S210 - S211
  • [27] Metal artifacts correction in cone-beam CT bone imaging
    Zhang, Yan
    Ning, Ruola
    Conover, David
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [28] Blood flow measurement by cone-beam CT bolus imaging
    Chen, Zikuan
    Ning, Ruola
    Conover, David
    Lu, Xianghua
    MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2, 2006, 6143
  • [29] A New Cone-Beam CT System for Bedside Head Imaging
    Sun, H.
    Zeng, W.
    Xu, P.
    Wang, Z.
    Xing, X.
    Sun, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3243 - 3244
  • [30] Cone-beam volume CT breast imaging: Feasibility study
    Chen, B
    Ning, R
    MEDICAL PHYSICS, 2002, 29 (05) : 755 - 770