Pull-out of axisymmetric headed anchors

被引:6
|
作者
Karihaloo, BL [1 ]
机构
[1] Univ Sydney, Sch Civil & Min Engn, Sydney, NSW 2003, Australia
关键词
D O I
10.1007/BF02486160
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A simple, albeit approximate, derivation of the pullout force of axisymmetric headed anchors is given by studying the growth of a penny crack in half space loaded only on its upper face. The initial diameter of the penny crack is equal to the head diameter. The formula so obtained does not contain any unknown constants. It is shown to be particularly accurate at large depths, of embedment for which the Code formula overestimates the puff-out force.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 50 条
  • [41] Experimental study on pull-out resistance of plate anchors at different buried depths
    Rui R.
    Xiao F.
    Cheng Y.
    Gao F.
    Hu S.
    Ding R.
    Sun T.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2023, 45 (10): : 2032 - 2041
  • [42] Pull-Out Mechanism of Horizontal and Inclined Plate Anchors in Normally Consolidated Clay
    Hu, Cun
    Chen, Junfeng
    Leung, Chun Fai
    Chow, Yean Khow
    Li, Zhichuan
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2021, 9 (10)
  • [43] Restoration of antique temples: Experimental investigations on the pull-out behaviour of anchors in marble
    Kourkoulis, Stavros
    Papanicolopulos, Stefanos-Aldo
    Marinelli, Aikaterini
    Vayas, Ioannis
    BAUTECHNIK, 2008, 85 (02) : 109 - 119
  • [44] PULL-OUT PROGRAMS
    BELLAFIORE, G
    JOURNAL OF LEARNING DISABILITIES, 1990, 23 (09) : 524 - 525
  • [45] An improved analysis for axisymmetric stress distributions in the single fibre pull-out test
    M. Y Quek
    C. Y Yue
    Journal of Materials Science, 1997, 32 : 5457 - 5465
  • [46] An improved analysis for axisymmetric stress distributions in the single fibre pull-out test
    Quek, MY
    Yue, CY
    JOURNAL OF MATERIALS SCIENCE, 1997, 32 (20) : 5457 - 5465
  • [47] Experimental pull-out tests and design indications for strength anchors installed in masonry walls
    Linda Giresini
    Mario Lucio Puppio
    Francesca Taddei
    Materials and Structures, 2020, 53
  • [48] Experimental pull-out tests and design indications for strength anchors installed in masonry walls
    Giresini, Linda
    Puppio, Mario Lucio
    Taddei, Francesca
    MATERIALS AND STRUCTURES, 2020, 53 (04)
  • [49] A NOTE ON THE OPTIMAL LOWER BOUND PULL-OUT CAPACITY OF INCLINED STRIP ANCHORS IN SAND
    SINGH, DN
    BASUDHAR, PK
    CANADIAN GEOTECHNICAL JOURNAL, 1992, 29 (05) : 870 - 873
  • [50] Analytical solution for the full-range pull-out behavior of FRP ground anchors
    Zheng, Jian-Jun
    Dai, Jian-Guo
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 58 : 129 - 137