Impacts of geometric structures on thermo-flow performances of plate fin-tube bundles

被引:18
|
作者
Kong, Y. Q. [1 ]
Yang, L. J. [1 ]
Du, X. Z. [1 ]
Yang, Y. P. [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Natural draft dry cooling system; Air-cooled heat exchanger; Finned tube bundles; Plate fin; Flow and heat transfer; Performance evaluation criterion; HEAT-TRANSFER; COOLING-TOWERS; FLAT TUBE; EXCHANGERS;
D O I
10.1016/j.ijthermalsci.2016.04.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
Continuous plate fin-tube heat exchangers are commonly applied to natural draft dry cooling system in power plants due to their excellent thermo-flow performances, but the effects of geometrical structures on the air-side flow and heat transfer characteristics have not been thoroughly clarified yet. In this study, the air-side flow and heat transfer models of plate fin-tube bundles are developed, and the numerical modeling and methods are validated by the experimental test. The thermo-flow characteristics of the plate fin-tube bundles at various parameters of air face velocity, fin oblique angle, fin spacing, fin thickness and tube external diameter are numerically simulated. The buoyancy effect due to natural convection is also investigated. The results show that the performance evaluation criterion (PK) varies little with the fin oblique angle. As the fin spacing increases, the average PEC will increase despite of a considerable heat transfer reduction. The increased fin thickness and tube external diameter are both beneficial to the thermo-flow characteristics, but the buoyancy effect on the flow and heat transfer performances can be neglected. The fin oblique angle of 30 degrees, fin spacing of 10 mm, fin thickness of 0.3 mm and tube external diameter of 18 mm are recommended within the scope of investigation. The correlations between the Nusselt number, friction factor and the Reynolds number and geometrical parameters are recommended using the orthogonal experimental design method, which can be used to the optimal design of air-cooled heat exchanger in power plants. (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:161 / 178
页数:18
相关论文
共 50 条
  • [41] Analysis of the thermal improvement of plate fin-tube heat exchanger with straight and curved rectangular winglet vortex generators
    Zhao, Lumei
    Qian, Zuoqin
    Wang, Xinyu
    Wang, Qiang
    Li, Changyi
    Zhang, Zhicheng
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [42] Effect of geometric size of curved delta winglet vortex generators and tube pitch on heat transfer characteristics of fin-tube heat exchanger
    Song, KeWei
    Xi, ZhiPeng
    Su, Mei
    Wang, LiangChen
    Wu, Xiang
    Wang, LiangBi
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 82 : 8 - 18
  • [43] 3-D numerical study on the correlation between variable inclined fin angles and thermal behavior in plate fin-tube heat exchanger
    Sahin, Haci Mehmet
    Dal, Ali Riza
    Baysal, Esref
    APPLIED THERMAL ENGINEERING, 2007, 27 (11-12) : 1806 - 1816
  • [44] Numerical study of the thermo-flow performances of novel finned tubes for air-cooled condensers in power plant
    Guo, Yonghong
    Du, Xiaoze
    Yang, Lijun
    INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2017), 2018, 121
  • [45] Local flow and heat transfer of a 2-row offset strip fin-tube heat exchanger
    Bae, JH
    Park, MH
    Lee, JH
    JOURNAL OF ENHANCED HEAT TRANSFER, 1999, 6 (01) : 13 - 29
  • [46] Effect of thermo-geometric parameters on entropy generation in absorber plate fin of a solar flat plate collector
    Jilani, G.
    Thomas, Ciby
    ENERGY, 2014, 70 : 35 - 42
  • [47] Thermo-hydraulic performances of internally finned tube with a new type wave fin arrays
    Peng, Hao
    Liu, Lin
    Ling, Xiang
    Li, Yang
    APPLIED THERMAL ENGINEERING, 2016, 98 : 1174 - 1188
  • [48] Wind effect on the thermo-flow performances and its decay characteristics for air-cooled condensers in a power plant
    Yang, L. J.
    Du, X. Z.
    Yang, Y. P.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 53 : 175 - 187
  • [49] The influence of the moments of probability density function for flow maldistribution on the thermal performance of a fin-tube heat exchanger
    Chin, Wai Meng
    Raghavan, Vijay R.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2011, 50 (10) : 1942 - 1953
  • [50] Local flow and heat transfer of a 2-row offset strip fin-tube heat exchanger
    Korea Power Engineering Research, Inst, Kyunggi-do, Korea, Republic of
    J Enhanced Heat Transfer, 1 (13-29):