Implementation of 3 T Lactate-Edited 3D 1H MR Spectroscopic Imaging with Flyback Echo-Planar Readout for Gliomas Patients

被引:32
|
作者
Park, Ilwoo [1 ,2 ]
Chen, Albert P. [3 ]
Zierhut, Matthew L. [1 ]
Ozturk-Isik, Esin [1 ]
Vigneron, Daniel B. [1 ,2 ]
Nelson, Sarah J. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Surbeck Lab Adv Imaging, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] UCSF UCB Joint Grad Grp Bioengn, San Francisco, CA USA
[3] GE Healthcare, Toronto, ON M5V 3Y3, Canada
关键词
3D magnetic resonance spectroscopic imaging; In vivo lactate detection; Brain tumor; Glioblastoma multiforme; BRAIN-TUMORS; IN-VIVO; CEREBRAL GLIOMAS; EMT6; TUMORS; LIPIDS; VOLUME; TESLA; EXCITATION; SEQUENCES; CHOLINE;
D O I
10.1007/s10439-010-0128-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to implement a new lactate-edited 3D H-1 magnetic resonance spectroscopic imaging (MRSI) sequence at 3 T and demonstrate the feasibility of using this sequence for measuring lactate in patients with gliomas. A 3D PRESS MRSI sequence incorporating shortened, high bandwidth 180 degrees pulses, new dual BASING lactate-editing pulses, high bandwidth very selective suppression (VSS) pulses and a flyback echo-planar readout was implemented at 3 T. Over-prescription factor of PRESS voxels was optimized using phantom to minimize chemical shift artifacts. The lactate-edited flyback sequence was compared with lactate-edited MRSI using conventional elliptical k-space sampling in a phantom and volunteers, and then applied to patients with gliomas. The results demonstrated the feasibility of detecting lactate within a short scan time of 9.5 min in both phantoms and patients. Over-prescription of voxels gave less chemical shift artifacts allowing detection of lactate on the majority of the selected volume. The normalized SNR of brain metabolites using the flyback encoding were comparable to the SNR of brain metabolites using conventional phase encoding MRSI. The specialized lactate-edited 3D MRSI sequence was able to detect lactate in brain tumor patients at 3 T. The implementation of this technique means that brain lactate can be evaluated in a routine clinical setting to study its potential as a marker for prognosis and response to therapy.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 50 条
  • [1] Implementation of 3 T Lactate-Edited 3D 1H MR Spectroscopic Imaging with Flyback Echo-Planar Readout for Gliomas Patients
    Ilwoo Park
    Albert P. Chen
    Matthew L. Zierhut
    Esin Ozturk-Isik
    Daniel B. Vigneron
    Sarah J. Nelson
    Annals of Biomedical Engineering, 2011, 39 : 193 - 204
  • [2] High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding
    Chen, Albert P.
    Cunningham, Charles H.
    Ozturk-Isik, Esin
    Xu, Duan
    Hurd, Ralph E.
    Kelley, Douglas A. C.
    Pauly, John M.
    Kurhanewicz, John
    Nelson, Sarah J.
    Vigneron, Daniel B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 1288 - 1292
  • [3] Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis
    Ebel, A
    Soher, BJ
    Maudsley, AA
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1072 - 1078
  • [4] Dynamic echo-planar MR imaging of the diaphragm for a 3D dynamic analysis
    S. Craighero
    E. Promayon
    P. Baconnier
    J. F. Lebas
    M. Coulomb
    European Radiology, 2005, 15 : 742 - 748
  • [5] Dynamic echo-planar MR imaging of the diaphragm for a 3D dynamic analysis
    Craighero, S
    Promayon, E
    Baconnier, P
    Lebas, JF
    Coulomb, M
    EUROPEAN RADIOLOGY, 2005, 15 (04) : 742 - 748
  • [6] Reproducibility of 3D 1H MR spectroscopic imaging of the prostate at 1.5T
    Lagemaat, Miriam W.
    Zechmann, Christian M.
    Futterer, Jurgen J.
    Weiland, Elisabeth
    Lu, Jianping
    Villeirs, Geert M.
    Holshouser, Barbara A.
    van Hecke, Paul
    Lemort, Marc
    Schlemmer, Heinz-Peter
    Barentsz, Jelle O.
    Roell, Stefan O.
    Heerschap, Arend
    Scheenen, Tom W. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (01) : 166 - 173
  • [7] 3D ECHO-PLANAR IMAGING - APPLICATION TO THE HUMAN HEAD
    ABDULJALIL, AM
    ALETRAS, AH
    ROBITAILLE, PML
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) : 144 - 148
  • [8] Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging
    Ebel, A
    Maudsley, AA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 465 - 469
  • [9] 3-DIMENSIONAL ECHO-PLANAR MR SPECTROSCOPIC IMAGING AT SHORT ECHO TIMES IN THE HUMAN BRAIN
    POSSE, S
    DECARLI, C
    LEBIHAN, D
    RADIOLOGY, 1994, 192 (03) : 733 - 738
  • [10] 31P-{1H} echo-planar spectroscopic imaging of the human brain in vivo
    Ulrich, M.
    Wokrina, T.
    Ende, G.
    Lang, M.
    Bachert, P.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 784 - 790