Radiopacity and Porosity of Bulk-fill and Conventional Composite Posterior Restorations-Digital X-ray Analysis

被引:25
|
作者
Soares, C. J. [1 ]
Rosatto, C. M. P. [1 ]
Carvalho, V. F. [1 ]
Bicalho, A. A. [1 ]
Henriques, J. C. G. [2 ]
Faria-e-Silva, A. L. [3 ]
机构
[1] Univ Fed Uberlandia, Dept Operat Dent & Dent Mat, Dent Sch, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Dent Sch, Dept Radiol & Stomatol, Uberlandia, MG, Brazil
[3] Univ Fed Sergipe, Dent Sch, Dept Operat Dent, Aracaju, Sergipe, Brazil
关键词
RESIN COMPOSITES; MARGINAL ADAPTATION; DENTAL MATERIALS; SYSTEMS; RADIODENSITY; METAANALYSIS; RADIOGRAPHY;
D O I
10.2341/16-146-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare radiopacity and porosity as expressed by the presence of voids in restorations carried out using bulk-fill and incremental filling techniques to restore large mesio-occlusal-distal (MOD) cavities. Methods: Fifty-five molars with MOD preparations were incrementally filled with Filtek Z-350XT (Z350XT) or bulk-fill composite: Filtek Bulk Fill/Z-350XT (FBF/Z350XT), Venus Bulk Fill/Charisma Diamond (VBF/CHA), SDR/Es-thet-X HD (SDR/EST-X), Tetric EvoCeram Bulk Fill (TEC). Digital radiographic images (Vista-scan scanner) were taken of restored molars and analyzed at the gingival and isthmus floors. Radiodensity measurements were performed using standardized points symmetrically distributed over each region of composite and tooth structure. Three calibrated evaluators visually assessed the presence of voids. Confidence intervals were calculated, and data were analyzed using analysis of variance and chi(2) tests. Results: TEC and VBF/CHA showed significantly higher radiodensities, while the lowest values were observed for FBF/Z350XT and Z350XT. Radiodensity at the cervical regions tended to be greater than that found at the isthmus floor. The lowest incidence of voids was found for VBF/CHA, whereas the incremental insertion technique resulted in the highest rate of voids. Conclusion: Bulk-fill composite resin demonstrated an adequate level of radiodensity and a reduced presence of voids compared with the incremental filling technique.
引用
收藏
页码:616 / 625
页数:10
相关论文
共 22 条
  • [21] Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry
    Vaccaro, Calogero
    Busetto, Roberto
    Bernardini, Daniele
    Anselmi, Carlo
    Zotti, Alessandro
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (03) : 381 - 384
  • [22] Torsion damage mechanisms analysis of two-dimensional braided composite tubes with digital image correction and X-ray micro-computed tomography
    Gu, Yuanhui
    Zhang, Diantang
    Zhang, Zhongwei
    Sun, Jie
    Yue, Songlin
    Li, Gan
    Qian, Kun
    COMPOSITE STRUCTURES, 2021, 256