Electrically conductive adhesives at microwave frequencies

被引:12
|
作者
Dernevik, M [1 ]
Sihlbom, R [1 ]
Axelsson, K [1 ]
Lai, ZH [1 ]
Liu, JH [1 ]
Starski, P [1 ]
机构
[1] Chalmers Univ Technol, Dept Microwave Engn, S-41296 Gothenburg, Sweden
关键词
D O I
10.1109/ECTC.1998.678839
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we present results from measurements on epoxy-based anisotropic and isotropic, electrically conductive adhesives, ACAs and ICAs respectively. We study two different types of connections, a flip-chip bonded silicon test chips and a simple transmission line gap bridged by a copper foil. These measurements are referenced to equivalent solder joints. The silicon chip is a standard test chip. The test chips are mounted on three different substrates, a rigid FR-4 board, flexible board and a high-frequency Teflon-based duroid substrate. We also discuss two electrical models for the connections, an equivalent RC model and a stochastic model, based on random particle distribution. The equivalent electrical model is based on physical considerations and the parameters are then fitted to measurement data in the high frequency CAD tool HP MDS. All the adhesive and solder interconnections are measured before and after temperature cycling and humidity tests. The temperature dependence of the connections S-parameters are also studied in a temperature controlled environment. A HP8510 network analyzer is used to measure scattering parameters. On rigid and flexible boards, the frequency range investigated is 500 MHz to 8 GHz, and on duroid mounted flip-chips and bridges, the range is 1 GHz to 30 GHz. The Thru-Reflect-Line calibration procedure is used to get the best possible calibration. Power testing is used with the Cu bridge assembly to find the maximum power transmission through an electrically conductive adhesive interconnect. This is done at relevant microwave frequencies Results indicate that the isotropic adhesive interconnections handle high power throughput well. The adhesive joints are subjected to a maximum peak pulsed power of 250 W. Maximum work factor of the pulsed signal is 10%. The effects of different particle sizes and materials in the ACAs are systematically investigated. Three different particle sizes and two particle materials are examined. All adhesives considered show similar electrical properties and are all suitable for adhesive electrical interconnections. The microstructure of the adhesive joints is studied by cross-sectioning using Scanning Electron Microscopy (SEM) before and after temperature cycling.
引用
下载
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [1] Characterization and performance of electrically conductive adhesives for microwave applications
    Felba, J
    Friedel, KP
    Moscicki, A
    4TH INTERNATIONAL CONFERENCE ON ADHESIVE JOINING AND COATING TECHNOLOGY IN ELECTRONICS MANUFACTURING - PROCEEDINGS, 2000, : 232 - 239
  • [2] Electrically conductive adhesives
    Gordon, Rachel
    Coating International, 2016, 49 (03): : 10 - 11
  • [3] Characterization of electrically conductive adhesives
    Eitner, U.
    Geipel, T.
    Holtschke, S. -N.
    Tranitz, M.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON CRYSTALLINE SILICON PHOTOVOLTAICS (SILICONPV 2012), 2012, 27 : 676 - 679
  • [4] ELECTRICALLY CONDUCTIVE COMPOSITE ADHESIVES
    Florian, Stepan
    Novak, Igor
    41. MEZINARODNI KONFERENCE O NATEROVYCH HMOTACH, KNH 2010, 2010, : 13 - 18
  • [5] Electrically conductive adhesives: An assessment
    Universitaet Erlangen-Nuernberg, Erlangen, Germany
    SMT Surf Mount Technol Mag, 5 (74, 76, 78):
  • [6] Electrically Conductive Epoxy Adhesives
    Sancaktar, Erol
    Bai, Lan
    POLYMERS, 2011, 3 (01) : 427 - 466
  • [7] Electrically conductive adhesives, thermally conductive adhesives and UV adhesives in data extraction forensics
    Heckmann, Thibaut
    Souvignet, Thomas
    Naccache, David
    DIGITAL INVESTIGATION, 2017, 21 : 53 - 64
  • [8] Cure kinetics of electrically conductive adhesives
    Geipel, Torsten
    Eitner, Ulrich
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON CRYSTALLINE SILICON PHOTOVOLTAICS (SILICONPV 2013), 2013, 38 : 340 - 347
  • [9] Fatigue behavior of electrically conductive adhesives
    George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive NW, Atlanta, GA 30332-0405, United States
    Journal of Adhesion Science and Technology, 2008, 22 (08): : 927 - 946
  • [10] Reliability of flexible electrically conductive adhesives
    Cui, Hui-wang
    Li, Dong-sheng
    Fan, Qiong
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2013, 24 (01) : 114 - 117