Objective breast symmetry analysis with the breast analyzing tool (BAT): improved tool for clinical trials

被引:22
|
作者
Krois, Wilfried [1 ]
Romar, Alexander Ken [1 ]
Wild, Thomas [1 ]
Dubsky, Peter [3 ]
Exner, Ruth [1 ,2 ]
Panhofer, Peter [1 ]
Jakesz, Raimund [1 ]
Gnant, Michael [1 ,2 ]
Fitzal, Florian [1 ,2 ]
机构
[1] Med Univ Vienna, Dept Surg, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Canc Comprehens Ctr Vienna, Breast Hlth Ctr, Spitalgasse 23, Vienna, Austria
[3] St Anna Brustzentrum, Hirslanden Klin, St Anna Str 32, CH-6006 Luzern, Switzerland
关键词
Breast symmetry; Objective breast analysis; Breast cosmetics; Breast analyzing tool; CANCER CONSERVATIVE TREATMENT; AESTHETIC EVALUATION;
D O I
10.1007/s10549-017-4255-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective cosmetic analysis is important to evaluate the cosmetic outcome after breast surgery or breast radiotherapy. For this purpose, we aimed to improve our recently developed objective scoring software, the Breast Analyzing Tool (BAT(A (R))). A questionnaire about important factors for breast symmetry was handed out to ten experts (surgeons) and eight non-experts (students). Using these factors, the first-generation BAT(A (R)) software formula has been modified and the breast symmetry index (BSI) from 129 women after breast surgery has been calculated by the first author with this new BAT(A (R)) formula. The resulting BSI values of these 129 breast cancer patients were then correlated with subjective symmetry scores from the 18 observers using the Harris scale. The BSI of ten images was also calculated from five observers different from the first author to calculate inter-rater reliability. In a second phase, the new BAT(A (R)) formula was validated and correlated with subjective scores of additional 50 women after breast surgery. The inter-rater reliability analysis of the objective evaluation by the BAT(A (R)) from five individuals showed an ICC of 0.992 with almost no difference between different observers. All subjective scores of 50 patients correlated with the modified BSI score with a high Pearson correlation coefficient of 0.909 (p < .001) which was better compared to the old software (r = 0.769; p < .001). The modified BAT(A (R)) software improves the correlation between subjective and objective BSI values, and may be a new standard for trials evaluating breast symmetry.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 50 条
  • [21] Enrollment calculator: Decisional analysis tool for assessment of clinical trials
    Yale, S. H.
    Squires, P.
    Chyou, P.
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 2006, 21 : 194 - 194
  • [22] Improving Breast Cancer Knowledge: The Use of a Computerized Breast Cancer Education Tool During a Clinical Consultation with a Breast Specialist
    Collins, Nerissa M.
    Vickers, Kristin S.
    Hathaway, Julie C.
    Croghan, Ivana T.
    Pruthi, Sandhya
    [J]. BREAST JOURNAL, 2014, 20 (02): : 207 - 209
  • [23] Weather surveillance radar as an objective tool for monitoring bat phenology and biogeography
    Stepanian, Phillip M.
    Wainwright, Charlotte E.
    Frick, Winifred F.
    Kelly, Jeffrey F.
    [J]. JOURNAL OF ENGINEERING-JOE, 2019, 2019 (20): : 7062 - 7064
  • [24] A Rasch analysis of the Burnout Assessment Tool (BAT)
    Hadzibajramovic, Emina
    Schaufeli, Wilmar
    De Witte, Hans
    [J]. PLOS ONE, 2020, 15 (11):
  • [25] Bioelectric Impedance Vector Analysis (BIVA) in Breast Cancer Patients: A Tool for Research and Clinical Practice
    Limon-Miro, Ana Teresa
    Valencia, Mauro E.
    Lopez-Teros, Veronica
    Guzman-Leon, Alan Eduardo
    Mendivil-Alvarado, Herminia
    Astiazaran-Garcia, Humberto
    [J]. MEDICINA-LITHUANIA, 2019, 55 (10):
  • [26] Color Doppler ultrasound as an objective assessment tool for chemotherapeutic response in advanced breast cancer
    Singh S.
    Pradhan S.
    Shukla R.C.
    Anson M.A.
    Kumar A.
    [J]. Breast Cancer, 2005, 12 (1) : 45 - 51
  • [27] COMPUTER-AIDED TOOL FOR BREAST TUMOUR ANALYSIS PURPOSES
    Palacios-Navarro, Guillermo
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCES ON INTERFACES AND HUMAN COMPUTER INTERACTION 2015, GAME AND ENTERTAINMENT TECHNOLOGIES 2015 AND COMPUTER GRAPHICS, VISUALIZATION, COMPUTER VISION AND IMAGE PROCESSING 2015, 2015, : 281 - 285
  • [28] Tissue microarray analysis as a screening tool for neuroendocrine carcinoma of the breast
    Brask, Julie Benedicte
    Talman, Maj-Lis Moller
    Wielenga, Vera Timmermans
    [J]. APMIS, 2014, 122 (07) : 593 - 598
  • [29] In silico analysis of angiogenesis pathway as a prognostic tool in breast cancer
    Mehta, Rutika J.
    Jain, Rohit K.
    Gokmen-Polar, Yesim
    Badve, Sunil
    [J]. CANCER RESEARCH, 2011, 71
  • [30] An Improved and Efficient Tool for Analyzing Industrial Security Protocols
    Liu, Nan
    Zhu, Yuefei
    Mao, Zhongquan
    Xu, Wei
    [J]. 2009 IITA INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS ENGINEERING, PROCEEDINGS, 2009, : 528 - 532