Multi-parametric T2* magnetic resonance fingerprinting using variable echo times

被引:18
|
作者
Wyatt, Cory R. [1 ,2 ]
Smith, Travis B. [1 ,3 ]
Sammi, Manoj K. [1 ]
Rooney, William D. [1 ]
Guimaraes, Alexander R. [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Adv Imaging Res Ctr, Portland, OR 97201 USA
[2] Oregon Hlth & Sci Univ, Dept Diagnost Radiol, 3181 Sw Sam Jackson Pk Rd, Portland, OR 97201 USA
[3] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
关键词
relaxometry; sampling strategies; susceptibility weighted imaging; QUANTITATIVE IMAGING BIOMARKERS; T-1; RELAXATION-TIME; LIVER FIBROSIS; TISSUE CHARACTERIZATION; BRAIN-TUMORS; 3.0T MRI; T2; T1; CARTILAGE; CANCER;
D O I
10.1002/nbm.3951
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of quantitative imaging biomarkers in the imaging of various disease states, including cancer and neurodegenerative disease, has increased in recent years. T-1, T-2, and T-2* relaxation time constants have been shown to be affected by tissue structure or contrast infusion. Acquiring these biomarkers simultaneously in a multi-parametric acquisition could provide more robust detection of tissue changes in various disease states including neurodegeneration and cancer. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T-1 and T-2 relaxation time constants. In this study, T-2* relaxation is added to the MRF framework using variable echo times (TE). To demonstrate the feasibility of the method and compare incremental and golden angle spiral rotations, simulated phantom data was fit using the proposed method. Additionally, T-1/T-2/T-2*/f MRF as well as conventional T-1, T-2, and T-2* acquisitions were acquired in agar phantoms and the brains of three healthy volunteers. Golden angle spiral rotation was found to reduce inaccuracy resulting from off resonance effects. Strong correlations were found between conventional and MRF values in the T-1, T-2, and T-2* relaxation time constants of the agar phantoms and healthy volunteers. In this study, T-2* relaxation has been incorporated into the MRF framework by using variable echo times, while still fitting for T-1 and T-2 relaxation time constants. In addition to fitting these relaxation time constants, a novel method for fitting and correcting off resonance effects has been developed.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Multi-parametric optimization of magnetic resonance imaging sequences for magnetic resonance-guided radiotherapy
    Fahad, Hafiz Muhammad
    Dorsch, Stefan
    Zaiss, Moritz
    Karger, Christian P.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [23] MULTI-PARAMETRIC RENAL MAGNETIC RESONANCE IMAGING IN EARLY KIDNEY TRANSPLANTATION
    Gillis, Keith
    Rankin, Alastair
    Allwood-Spiers, Sarah
    Woodward, Rosemary
    Roditi, Giles
    Radjenovic, Aleksandra
    Kuehn, Bernd
    Patel, Rajan
    Mark, Patrick
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 597 - 597
  • [24] Deep learning reconstruction for cardiac magnetic resonance fingerprinting T1 and T2 mapping
    Hamilton, Jesse I.
    Currey, Danielle
    Rajagopalan, Sanjay
    Seiberlich, Nicole
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 2127 - 2135
  • [25] Radiogenomic analysis of PTEN mutation in glioblastoma using preoperative multi-parametric magnetic resonance imaging
    Li, Yiming
    Liang, Yuchao
    Sun, Zhiyan
    Xu, Kaibin
    Fan, Xing
    Li, Shaowu
    Zhang, Zhong
    Jiang, Tao
    Liu, Xing
    Wang, Yinyan
    NEURORADIOLOGY, 2019, 61 (11) : 1229 - 1237
  • [26] Radiogenomic analysis of PTEN mutation in glioblastoma using preoperative multi-parametric magnetic resonance imaging
    Yiming Li
    Yuchao Liang
    Zhiyan Sun
    Kaibin Xu
    Xing Fan
    Shaowu Li
    Zhong Zhang
    Tao Jiang
    Xing Liu
    Yinyan Wang
    Neuroradiology, 2019, 61 : 1229 - 1237
  • [27] Treatment Efficacy Prediction of Focused Ultrasound Therapies Using Multi-parametric Magnetic Resonance Imaging
    Singh, Amanpreet
    Adams-Tew, Samuel
    Johnson, Sara
    Odeen, Henrik
    Shea, Jill
    Johnson, Audrey
    Day, Lorena
    Pessin, Alissa
    Payne, Allison
    Joshi, Sarang
    CANCER PREVENTION, DETECTION, AND INTERVENTION, CAPTION 2024, 2025, 15199 : 190 - 199
  • [28] Simultaneous multi-parametric mapping of total sodium concentration, T1, T2 and ADC at 7 T using a multi-contrast unbalanced SSFP
    Leroi, Lisa
    Coste, Arthur
    de Rochefort, Ludovic
    Santin, Mathieu D.
    Valabregue, Romain
    Mauconduit, Franck
    Giacomini, Eric
    Luong, Michel
    Chazel, Edouard
    Valette, Julien
    Le Bihan, Denis
    Poupon, Cyril
    Boumezbeur, Fawzi
    Rabrait-Lerman, Cecile
    Vignaud, Alexandre
    MAGNETIC RESONANCE IMAGING, 2018, 53 : 156 - 163
  • [29] ITERATIVE ESTIMATION OF T2 TO CORRECT ECHO PLANAR MAGNETIC-RESONANCE IMAGES
    SINGH, M
    OSHIO, K
    BRECHNER, RR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 795 - 799
  • [30] SUSCEPTIBILITY, ECHO TIME SHIFTS, AND T2*CONSIDERATIONS FOR FUNCTIONAL MAGNETIC RESONANCE IMAGING
    Sutton, Bradley P.
    Zhuo, Yue
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 710 - 713