Multi-parametric T2* magnetic resonance fingerprinting using variable echo times

被引:18
|
作者
Wyatt, Cory R. [1 ,2 ]
Smith, Travis B. [1 ,3 ]
Sammi, Manoj K. [1 ]
Rooney, William D. [1 ]
Guimaraes, Alexander R. [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Adv Imaging Res Ctr, Portland, OR 97201 USA
[2] Oregon Hlth & Sci Univ, Dept Diagnost Radiol, 3181 Sw Sam Jackson Pk Rd, Portland, OR 97201 USA
[3] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
关键词
relaxometry; sampling strategies; susceptibility weighted imaging; QUANTITATIVE IMAGING BIOMARKERS; T-1; RELAXATION-TIME; LIVER FIBROSIS; TISSUE CHARACTERIZATION; BRAIN-TUMORS; 3.0T MRI; T2; T1; CARTILAGE; CANCER;
D O I
10.1002/nbm.3951
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of quantitative imaging biomarkers in the imaging of various disease states, including cancer and neurodegenerative disease, has increased in recent years. T-1, T-2, and T-2* relaxation time constants have been shown to be affected by tissue structure or contrast infusion. Acquiring these biomarkers simultaneously in a multi-parametric acquisition could provide more robust detection of tissue changes in various disease states including neurodegeneration and cancer. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T-1 and T-2 relaxation time constants. In this study, T-2* relaxation is added to the MRF framework using variable echo times (TE). To demonstrate the feasibility of the method and compare incremental and golden angle spiral rotations, simulated phantom data was fit using the proposed method. Additionally, T-1/T-2/T-2*/f MRF as well as conventional T-1, T-2, and T-2* acquisitions were acquired in agar phantoms and the brains of three healthy volunteers. Golden angle spiral rotation was found to reduce inaccuracy resulting from off resonance effects. Strong correlations were found between conventional and MRF values in the T-1, T-2, and T-2* relaxation time constants of the agar phantoms and healthy volunteers. In this study, T-2* relaxation has been incorporated into the MRF framework by using variable echo times, while still fitting for T-1 and T-2 relaxation time constants. In addition to fitting these relaxation time constants, a novel method for fitting and correcting off resonance effects has been developed.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Magnetic Resonance Fingerprinting Using Echo-Planar Imaging: Joint Quantification of T1 and T2* Relaxation Times
    Rieger, Benedikt
    Zimmer, Fabian
    Zapp, Jascha
    Weingaertner, Sebastian
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1724 - 1733
  • [2] Multi-parametric liver tissue characterization using MR fingerprinting: Simultaneous T1, T2, T2*, and fat fraction mapping
    Jaubert, Olivier
    Arrieta, Cristobal
    Cruz, Gastao
    Bustin, Aurelien
    Schneider, Torben
    Georgiopoulos, Georgios
    Masci, Pier-Giorgio
    Sing-Long, Carlos
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2625 - 2635
  • [3] Quantification of T1, T2 relaxation times from Magnetic Resonance Fingerprinting radially undersampled data using analytical transformations
    Dikaios, Nikolaos
    Protonotarios, Nicholas E.
    Fokas, Athanasios S.
    Kastis, George A.
    MAGNETIC RESONANCE IMAGING, 2021, 80 : 81 - 89
  • [4] T2 MAGNETIC RESONANCE FINGERPRINTING IN GLOBAL AND FOCAL KNEE CARTILAGE
    Sitarcikova, Diana
    Janacova, Veronika
    Hristoska, Barbara
    Gologan, Malina
    Cloos, Martijn A.
    Trattnig, Siegfried
    Juras, Vladimir
    OSTEOARTHRITIS AND CARTILAGE, 2024, 32 : S345 - S346
  • [5] Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times
    Stock, KW
    Chen, Q
    Hatabu, H
    Edelman, RR
    MAGNETIC RESONANCE IMAGING, 1999, 17 (07) : 997 - 1000
  • [6] T1 and T2 quantification using magnetic resonance fingerprinting in mild traumatic brain injury
    Teresa Gerhalter
    Martijn Cloos
    Anna M. Chen
    Seena Dehkharghani
    Rosemary Peralta
    James S. Babb
    Alejandro Zarate
    Tamara Bushnik
    Jonathan M. Silver
    Brian S. Im
    Stephen Wall
    Steven Baete
    Guillaume Madelin
    Ivan I. Kirov
    European Radiology, 2022, 32 : 1308 - 1319
  • [7] T1 and T2 quantification using magnetic resonance fingerprinting in mild traumatic brain injury
    Gerhalter, Teresa
    Cloos, Martijn
    Chen, Anna M.
    Dehkharghani, Seena
    Peralta, Rosemary
    Babb, James S.
    Zarate, Alejandro
    Bushnik, Tamara
    Silver, Jonathan M.
    Im, Brian S.
    Wall, Stephen
    Baete, Steven
    Madelin, Guillaume
    Kirov, Ivan I.
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 1308 - 1319
  • [8] Contrast behavior and image quality of magnetic resonance cholangiopancreatography imaging using variable echo times at 3.0 T
    Isoda, Hiroyoshi
    Maetani, Yoji
    Kataoka, Masako
    Arizono, Shigeki
    Shimada, Kotaro
    Hirokawa, Ybusuke
    Nakamoto, Yuji
    Togashi, Kaoni
    CLINICAL IMAGING, 2008, 32 (05) : 362 - 366
  • [9] Multi-parametric magnetic resonance imaging as a management decision tool
    Johnson, David C.
    Reiter, Robert E.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2017, 6 (03) : 472 - 482
  • [10] Ultrashort echo time magnetic resonance fingerprinting (UTE-MRF) for simultaneous quantification of long and ultrashort T2 tissues
    Li, Qing
    Cao, Xiaozhi
    Ye, Huihui
    Liao, Congyu
    He, Hongjian
    Zhong, Jianhui
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1359 - 1372