Safety and Efficacy of Stent-Assisted Coiling of Unruptured Intracranial Aneurysms Using Low-Profile Stents in Small Parent Arteries

被引:16
|
作者
Kim, J. [1 ]
Han, H. J. [1 ]
Lee, W. [2 ]
Park, S. K. [2 ]
Chung, J. [1 ]
Kim, Y. B. [1 ]
Park, K. Y. [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Hosp, Coll Med, Dept Neurosurg,Severance Stroke Ctr, Seoul, South Korea
[2] Yonsei Univ, Gangnam Severance Hosp, Coll Med, Dept Neurosurg, 50 Yonsei Ro, Seoul 03722, South Korea
关键词
ENDOVASCULAR TREATMENT; LVIS JR; EMBOLIZATION; SMOKING;
D O I
10.3174/ajnr.A7196
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Stent-assisted coiling of intracranial aneurysms arising from small vessels (<= 2.0mm) is a common procedure. However, data regarding its treatment outcomes are scarce. This study evaluated the clinical and radiologic outcomes of stent-assisted coiling using low-profile stents for aneurysms of small parent arteries. MATERIALS AND METHODS: From November 2015 to October 2020, sixty-four patients with 66 aneurysms arising from parent arteries of <= 2.0mm were treated with stent-assisted coiling using a Low-Profile Visualized Intraluminal Support Junior (LVIS Jr) or the Neuroform Atlas stent in a single institution. The clinical and radiologic data were retrospectively reviewed, and the risk factors for procedure-related complications were evaluated. RESULTS: The LVIS Jr and Neuroform Atlas stents were used in 22 (33.3%) and 44 (66.7%) cases, respectively. Technical success was achieved in 66 cases (100%). Immediate postprocedural aneurysm occlusion grades assessed by the Raymond-Roy occlusion classification were I (57.6%), II (19.7%), and III (22.7%), respectively. Procedure-related complications occurred in 10 cases (15.2%), with 8 thromboembolic complications (12.1%) and 2 hemorrhagic complications (3.0%). Procedure-related morbidity was 4.5% without mortality. On multivariate analysis, current smoking (odds ratio = 7.1, P = .021) had a statistically significant effect on procedure-related complications. CONCLUSIONS: Stent-assisted coiling of intracranial aneurysms with low-profile stents in small vessels (<= 2.0 mm) had a 100% success rate and a 15.2% overall complication rate with 4.5% morbidity. Current smoking was a significant risk factor associated with procedure-related complications.
引用
收藏
页码:1621 / 1626
页数:6
相关论文
共 50 条
  • [31] Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms: comparison of LVIS stents with laser-cut stents
    Xue Gaici
    Zuo Qiao
    Zhang Xiaoxi
    Tang Haishuang
    Zhao Rui
    Li Qiang
    Fang Yibin
    Yang Pengfei
    Hong Bo
    Xu Yi
    Huang Qinghai
    Liu Jianmin
    中华神经外科杂志(英文), 2021, 07 (02) : 116 - 125
  • [32] Midterm results of T-stent-assisted coiling of wide-necked and complex intracranial bifurcation aneurysms using low-profile stents
    Aydin, Kubilay
    Sencer, Serra
    Barburoglu, Mehmet
    Berdikhojayev, Mynzhylky
    Aras, Yavuz
    Sencer, Altay
    Izgi, Nail
    JOURNAL OF NEUROSURGERY, 2017, 127 (06) : 1288 - 1296
  • [33] Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis
    Kuhn, Anna Luisa
    Hou, Samuel Y.
    Puri, Ajit S.
    Silva, Christine F.
    Gounis, Matthew J.
    Wakhloo, Ajay K.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (06) : 581 - 585
  • [34] Clinical and angiographic outcomes of stent-assisted coiling of intracranial aneurysms
    Ghinda, Diana
    dos Santos, Marlise Peruzzo
    Sabri, Armin
    Iancu, Daniela
    Lum, Cheemun
    Lesiuk, Howard J.
    INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (02) : 146 - 154
  • [35] Threshold for Packing Density in Stent-Assisted Coiling of Intracranial Aneurysms
    Chalouhi, Nohra
    Dumont, Aaron S.
    Tjoumakaris, Stavropoula I.
    Gonzalez, Fernando
    Starke, Robert M.
    Dalyai, Richard
    El Moursi, Sedeek
    Rosenwasser, Robert H.
    Hasan, David M.
    Jabbour, Pascal
    NEUROSURGERY, 2012, 71 (02) : E553 - E553
  • [36] Comparison of Devices Used for Stent-Assisted Coiling of Intracranial Aneurysms
    Izar, Benjamin
    Rai, Ansaar
    Raghuram, Karthikram
    Rotruck, Jill
    Carpenter, Jeffrey
    PLOS ONE, 2011, 6 (09):
  • [37] Balloon Remodeling May Improve Angiographic Results of Stent-Assisted Coiling of Unruptured Intracranial Aneurysms COMMENTS
    Kuker, Wilhelm
    Guterman, Lee R.
    NEUROSURGERY, 2015, 76 (04) : 445 - 445
  • [38] Comparison of Stent-Assisted Coiling vs Coiling Alone in 563 Intracranial Aneurysms: Safety and Efficacy at a High-Volume Center
    Yang, Hongchao
    Sun, Yong
    Jiang, Yuhua
    Lv, Xianli
    Zhao, Yang
    Li, Youxiang
    Liu, Aihua
    NEUROSURGERY, 2015, 77 (02) : 241 - 247
  • [39] Comparison of Enterprise With Neuroform Stent-Assisted Coiling of Intracranial Aneurysms
    Kadkhodayan, Yasha
    Rhodes, Nicholas
    Blackburn, Spiros
    Derdeyn, Colin P.
    Cross, DeWitte T., III
    Moran, Christopher J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 872 - 878
  • [40] Preliminary Single-center Experience with Neuroform Atlas Stent-assisted Coiling for Unruptured Intracranial Aneurysms
    Ciccio', Gabriele
    Smajda, Stanislas
    Robert, Thomas
    Blanc, Raphael
    Redjem, Hocine
    Takezawa, Hidesato
    Sasannejad, Payam
    Piotin, Michel
    STROKE, 2017, 48