Repeatability of Anterior Eye Surface Topography Parameters from an Anterior Eye Surface Profilometer

被引:2
|
作者
Niyazmand, Hamed [1 ]
Read, Scott A. [1 ]
Atchison, David A. [2 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Ctr Vis & Eye Res, Contact Lens & Visual Opt Lab, Kelvin Grove, Qld, Australia
[2] Queensland Univ Technol, Sch Optometry & Vis Sci, Ctr Vis & Eye Res, Visual & Ophthalm Opt Lab, Kelvin Grove, Qld, Australia
关键词
CORNEOSCLERAL TOPOGRAPHY; CORNEAL TOPOGRAPHY; SCLERAL TOPOGRAPHY; CONTACT-LENSES; SHAPE; AGREEMENT; GLAUCOMA; DESIGN; LIMBAL;
D O I
10.1097/OPX.0000000000001789
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE Anterior eye shape measurements are important for clinical contact lens fitting. The detailed assessment of measurement repeatability using the Eye Surface Profiler (ESP; Eaglet Eye B.V., AP Houten, the Netherlands) allows for more reliable interpretation of eye surface topography measurements. PURPOSE This study aimed to determine the repeatability of the ESP for anterior central corneal power and anterior eye surface height measurements. METHODS A Badal optometer was mounted on the ESP to provide an external fixation target with appropriate accommodation control and refractive correction. Forty-five healthy young adults underwent two sessions of anterior eye measurements, separated by 20 minutes, using the ESP. In each session, three consecutive scans were captured. Sagittal height data were obtained from 8-mm central cornea and from 8- to 14-mm diameter (encompassing the corneal periphery and anterior sclera). Anterior corneal powers were determined from the central cornea. Intersessional and intrasessional repeatability values were determined as coefficients of repeatability and root mean square error differences. RESULTS Sagittal height intersessional coefficients of repeatability for central nasal (5 mu m) and central temporal (7 mu m) were better than peripheral nasal (24 mu m) and peripheral temporal (21 mu m) regions. Sagittal height intrasessional coefficients of repeatability were 9, 8, 28, and 31 mu m for central nasal, central temporal, peripheral nasal, and peripheral temporal regions, respectively. Intersessional coefficients of repeatability of mean sphere, 90/180 degrees (J(0)) astigmatism, and oblique (J(45)) astigmatism were 0.67, 0.22, and 0.13 D, respectively, with corresponding intrasessional coefficients of repeatability of 1.27, 0.21, and 0.27 D. CONCLUSIONS The modified measuring procedure for the ESP used in this study provides highly repeatable sagittal height measurements in the central cornea but is less repeatable in the corneal periphery and scleral region. Results of the current study can be considered when using ESP in the interpretation of anterior eye surface shape measurements and in contact lens fitting and design.
引用
收藏
页码:1203 / 1209
页数:7
相关论文
共 50 条
  • [31] REFORMATION OF ANTERIOR CHAMBER OF EYE
    BREFFEILH, LA
    SOUTHERN MEDICAL JOURNAL, 1968, 61 (08) : 871 - +
  • [32] Burns of the anterior segment of the eye
    不详
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1934, 103 : 1633 - 1633
  • [33] Ultraviolet Radiation and the Anterior Eye
    Coroneo, Minas
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (04): : 214 - 224
  • [34] SURGERY OF ANTERIOR SEGMENT OF EYE
    不详
    ARCHIVES OF OPHTHALMOLOGY, 1965, 73 (04) : 602 - +
  • [35] The anterior segment of the eye in diabetes
    Adeoti, C. O.
    Isawumi, M. A.
    Ashaye, A. O.
    Olomola, B. V.
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 667 - 671
  • [36] Anterior eye health recording
    Wolffsohn, James S.
    Naroo, Shehzad A.
    Christie, Caroline
    Morris, Judith
    Conway, Robert
    Maldonado-Codina, Carole
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (04): : 266 - 271
  • [37] Eye Symptom Questionnaire to Evaluate Anterior Eye Health
    Woodward, Maria A.
    Valikodath, Nita G.
    Newman-Casey, Paula Anne
    Niziol, Leslie M.
    Musch, David C.
    Lee, Paul P.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (06): : 384 - 389
  • [38] ANTERIOR CHAMBER OF COELACANTH EYE
    COLE, DF
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1968, 52 (05) : 415 - +
  • [39] Objective Grading of The Anterior Eye
    Peterson, Rachael C.
    Wolffsohn, James S.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (03) : 273 - 278
  • [40] Automatic biometrics of the anterior eye
    Iskander, DR
    Collins, MJ
    Davis, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U1002 - U1002