Repeatability of Anterior Eye Surface Topography Parameters from an Anterior Eye Surface Profilometer

被引:2
|
作者
Niyazmand, Hamed [1 ]
Read, Scott A. [1 ]
Atchison, David A. [2 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Ctr Vis & Eye Res, Contact Lens & Visual Opt Lab, Kelvin Grove, Qld, Australia
[2] Queensland Univ Technol, Sch Optometry & Vis Sci, Ctr Vis & Eye Res, Visual & Ophthalm Opt Lab, Kelvin Grove, Qld, Australia
关键词
CORNEOSCLERAL TOPOGRAPHY; CORNEAL TOPOGRAPHY; SCLERAL TOPOGRAPHY; CONTACT-LENSES; SHAPE; AGREEMENT; GLAUCOMA; DESIGN; LIMBAL;
D O I
10.1097/OPX.0000000000001789
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE Anterior eye shape measurements are important for clinical contact lens fitting. The detailed assessment of measurement repeatability using the Eye Surface Profiler (ESP; Eaglet Eye B.V., AP Houten, the Netherlands) allows for more reliable interpretation of eye surface topography measurements. PURPOSE This study aimed to determine the repeatability of the ESP for anterior central corneal power and anterior eye surface height measurements. METHODS A Badal optometer was mounted on the ESP to provide an external fixation target with appropriate accommodation control and refractive correction. Forty-five healthy young adults underwent two sessions of anterior eye measurements, separated by 20 minutes, using the ESP. In each session, three consecutive scans were captured. Sagittal height data were obtained from 8-mm central cornea and from 8- to 14-mm diameter (encompassing the corneal periphery and anterior sclera). Anterior corneal powers were determined from the central cornea. Intersessional and intrasessional repeatability values were determined as coefficients of repeatability and root mean square error differences. RESULTS Sagittal height intersessional coefficients of repeatability for central nasal (5 mu m) and central temporal (7 mu m) were better than peripheral nasal (24 mu m) and peripheral temporal (21 mu m) regions. Sagittal height intrasessional coefficients of repeatability were 9, 8, 28, and 31 mu m for central nasal, central temporal, peripheral nasal, and peripheral temporal regions, respectively. Intersessional coefficients of repeatability of mean sphere, 90/180 degrees (J(0)) astigmatism, and oblique (J(45)) astigmatism were 0.67, 0.22, and 0.13 D, respectively, with corresponding intrasessional coefficients of repeatability of 1.27, 0.21, and 0.27 D. CONCLUSIONS The modified measuring procedure for the ESP used in this study provides highly repeatable sagittal height measurements in the central cornea but is less repeatable in the corneal periphery and scleral region. Results of the current study can be considered when using ESP in the interpretation of anterior eye surface shape measurements and in contact lens fitting and design.
引用
收藏
页码:1203 / 1209
页数:7
相关论文
共 50 条
  • [1] Repeatability of anterior eye surface topography parameters from the Eye Surface Profiler
    Niyazmand, Hamed
    Read, Scott A.
    Atchison, David A.
    Collins, Michael J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [2] Determining the position of limbus corneae from anterior eye surface topography
    Consejo, Alejandra
    Iskander, D. Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Allergic inflammation of the anterior surface of the eye
    Bielory, Leonard
    ALLERGY AND ASTHMA PROCEEDINGS, 2020, 41 (06) : 449 - 453
  • [4] Scleral radius estimation based on anterior eye surface
    Katarzyna Garaszczuk, Izabela
    Mousavi, Maryam
    Cervino Exposito, Alejandro
    Szczesna-Iskander, Dorota Helena
    Iskander, Robert
    de Jesus, Danilo Andrade
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] OXYGEN DELIVERY TO THE ANTERIOR-CHAMBER OF THE EYE - A NOVEL FUNCTION OF THE ANTERIOR IRIS SURFACE
    HOPER, J
    FUNK, R
    ZAGORSKI, Z
    ROHEN, JW
    CURRENT EYE RESEARCH, 1989, 8 (07) : 649 - 659
  • [6] Development of a wide field height eye topographer: Validation on models of the anterior eye surface
    Department of Ophthalmology, University Hospital, Maastricht, Netherlands
    不详
    不详
    Optom. Vis. Sci., 1 (69-77):
  • [7] Development of a wide field height eye topographer: Validation on models of the anterior eye surface
    Jongsma, FHM
    De Brabander, J
    Hendrikse, F
    Stultiens, BAT
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (01) : 69 - 77
  • [8] Are the fluctuations in dynamic anterior surface aberrations of the human eye chaotic?
    Jayakumar, Varadharajan
    Thapa, Damber
    Hutchings, Natalie
    Lakshminarayanan, Vasudevan
    OPTICS LETTERS, 2013, 38 (24) : 5208 - 5211
  • [9] THE TOPOGRAPHY OF THE ANTERIOR SURFACE OF THE CATS CORNEA
    CARRINGTON, SD
    WOODWARD, EG
    CURRENT EYE RESEARCH, 1984, 3 (06) : 823 - 826
  • [10] The relation between physical properties of the anterior eye and ocular surface temperature
    Purslow, Christine
    Wolffsohn, James
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (03) : 197 - 201