Magnesium isotopic homogeneity of San Carlos olivine: a potential standard for Mg isotopic analysis by multi-collector inductively coupled plasma mass spectrometry

被引:34
|
作者
Hu, Yan [1 ]
Harrington, Melissa D. [1 ]
Sun, Yang [1 ,2 ]
Yang, Zhe [1 ,3 ]
Konter, Jasper [4 ]
Teng, Fang-Zhen [1 ]
机构
[1] Univ Washington, Dept Earth & Space Sci, Isotope Lab, Seattle, WA 98195 USA
[2] Chinese Acad Sci, Inst Geol & Geophys, State Key Lab Lithospher Evolut, Beijing 100029, Peoples R China
[3] China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Beijing 100083, Peoples R China
[4] Univ Hawaii Manoa, Dept Geol & Geophys, Honolulu, HI 96822 USA
基金
美国国家科学基金会;
关键词
MC-ICP-MS; ULTRAMAFIC INCLUSIONS; MANTLE; EARTH; FRACTIONATION; CHONDRITES; PETROGENESIS; SYSTEMATICS; XENOLITHS; BEHAVIOR;
D O I
10.1002/rcm.7700
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: Previous analyses on San Carlos olivine from Arizona (USA) have shown inter-laboratory delta Mg-26 differences of up to 0.67 parts per thousand, while mantle olivine samples worldwide are homogeneous at a current analytical uncertainty of similar to 0.1 parts per thousand. The differing measurements on San Carlos olivine may be attributable to analytical artifacts or sample heterogeneity. The latter must be ruled out before using it as a standard for Mg isotopic analysis. MethodsTo examine sample homogeneity, two different batches of San Carlos olivine from a lherzolite and four batches from a harzburgite have been analyzed together with coexisting harzburgitic pyroxene. In addition, the effect of acid purity on resin performance and the reusability of AG50W-X8 resin for Mg separation have been evaluated by processing another batch of lherzolitic San Carlos olivine and Hawaiian seawater through both new and used resins cleaned with different acids. ResultsSix different batches of olivine grains from two San Carlos peridotite xenoliths show homogeneous Mg-26 values to within 0.03 parts per thousand, and all the mineral phases in the harzburgite are in Mg isotope equilibrium. Furthermore, there is no resolvable Mg-26 shift in either lherzolitic San Carlos olivine or Hawaiian seawater by using either new or used resins that were cleaned with single-distilled or double-distilled acids. ConclusionsThe new data are consistent with the narrow Mg-26 range of mantle olivine worldwide, while they stand in contrast to the wide range measured on the same San Carlos olivine powder in different laboratories. Therefore, previous inter-laboratory discrepancies reflect analytical artifacts instead of sample heterogeneity, and San Carlos olivine is a suitable standard for Mg isotopic analysis. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:2123 / 2132
页数:10
相关论文
共 50 条
  • [1] Measurement of isotopic ratios of uranium by multi-collector inductively coupled plasma mass spectrometry
    Li, Li-Li
    Li, Jin-Ying
    Zhao, Yong-Gang
    Liu, Jun-Ling
    Zhang, Ji-Long
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2006, 28 (03): : 152 - 156
  • [2] Determination of magnesium isotopic ratios of biological reference materials via multi-collector inductively coupled plasma mass spectrometry
    Goff, Samuel Le
    Albalat, Emmanuelle
    Dosseto, Anthony
    Godin, Jean-Philippe
    Balter, Vincent
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (10)
  • [3] Determination of Eu isotopic ratio by multi-collector inductively coupled plasma mass spectrometry using a Sm internal standard
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 156 : 42 - 50
  • [4] Precise analysis of potassium isotopic composition in plant materials by multi-collector inductively coupled plasma mass spectrometry
    He, Mao-Yong
    Ren, Tong Xiang
    Jin, Zhang Dong
    Deng, Li
    Liu, Hai Jiao
    Cheng, Yuan Yuan
    Li, Zheng Yan
    Liu, Xing Xing
    Yang, Yang
    Chang, Hong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 209
  • [5] In situ Analysis of Mg Isotopic Compositions of Basalt Glasses by Femtosecond Laser Ablation Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Dai Meng-Ning
    Bao Zhi-An
    Chen Kai-Yun
    Yuan Hong-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 173 - 177
  • [6] An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry
    Barling, Jane
    Weis, Dominique
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) : 653 - 662
  • [7] Accurate lithium isotopic analysis of twenty geological reference materials by multi-collector inductively coupled plasma mass spectrometry
    Li, Xiaoqiang
    Han, Guilin
    Zhang, Qian
    Qu, Rui
    Miao, Zhuang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 188
  • [8] Absolute isotopic composition and atomic weight of selenium using multi-collector inductively coupled plasma mass spectrometry
    Wang, Jun
    Ren, Tongxiang
    Lu, Hai
    Zhou, Tao
    Zhao, Motian
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 308 (01) : 65 - 70
  • [9] Standard-sample bracketing calibration method combined with Mg as an internal standard for silicon isotopic compositions using multi-collector inductively coupled plasma mass spectrometry
    Yuan H.
    Cheng C.
    Chen K.
    Bao Z.
    Acta Geochimica, 2016, 35 (4) : 421 - 427
  • [10] Standard-sample bracketing calibration method combined with Mg as an internal standard for silicon isotopic compositions using multi-collector inductively coupled plasma mass spectrometry
    Honglin Yuan
    Cheng Cheng
    Kaiyun Chen
    Zhian Bao
    Acta Geochimica, 2016, (04) : 421 - 427